HOW HIGH AND LOW PRESSURE SAFETY SWITCHES OF A HVAC/ AC SYSTEM WORKS

  Рет қаралды 124,228

D2D NY Real World HVAC Simplified

D2D NY Real World HVAC Simplified

3 жыл бұрын

How high and low pressure safety works and wired in a HVAC system .. how to install them • HVAC HACKS REPLACING B... #d2dnyac #hvac
My Affiliate hvac tools links
Get tools here👇
amzn.to/3zcA2An - 2 pcs = 8 pcs box speed wrench
amzn.to/40sma0T - hvac service wrench
amzn.to/42K1CT7 - tool bag pack
amzn.to/3ZoKW0G - allen wrench
amzn.to/40INoju - coil brush
amzn.to/3FWlrwG - utility knife
amzn.to/3ZlsMwz - channel lock pliers
amzn.to/3TTo0p1 - pipe wrench
amzn.to/3FXjdx9 - adjustable wrench
amzn.to/40Buuem - tape measure
amzn.to/42J1dQN - wire jumpers for controls
amzn.to/42IZcnP - 1/8 inch flat screw driver
amzn.to/3KepgA7 - 11 in 1 nut and screw d
amzn.to/3nqQn1P - pocket Thermometer
amzn.to/3wqTXcQ - Muli meter/ ohm meter/ electric tester
amzn.to/3mQ69AA - Guages
amzn.to/3ocT2ci - Wire striper
amzn.to/3lPu3hU - copper pipe cutter
amzn.to/3FTchAW - testo 557s

Пікірлер: 161
@chrisgomez724
@chrisgomez724 2 жыл бұрын
This videos is very informative, I do residential so troubleshooting high and low switches would be awesome!! Keep up the good work my man!!
@BallzToYou7
@BallzToYou7 3 жыл бұрын
Thank you so much. You dont understand how perfect and a godsend your channel is right now!!!!!
@williamtorres810
@williamtorres810 3 жыл бұрын
That was an awesome explanation..I had and RTU that was having pressure switch problem and thanks to this awesome video I was able to pinpoint the issue..Thanks man 👍👍
@hechos1v8
@hechos1v8 2 жыл бұрын
Very professional video. I love the way you explained step-by-step, you make it easy to understand better. Thanks Will B
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thank you for stopping by
@DWAYNE2ism
@DWAYNE2ism 3 жыл бұрын
Great video really simplified .
@krishnasilwal4834
@krishnasilwal4834 20 күн бұрын
Hard to find information KZbin about this switch. Thank you for information
@D2DNYAC
@D2DNYAC 15 күн бұрын
The switch is simply based on the type of refrigerant inside the system
@alfredhines505
@alfredhines505 3 жыл бұрын
At 55psi the circuit will closed and at 30 psi the circuit will open to protect the compressor, due to the low pressure.
@tebbink
@tebbink 4 ай бұрын
Untuk saklar tekanan tinggi berapa range tekanannya?
@josearturobarajas4913
@josearturobarajas4913 Жыл бұрын
I loved the video, it was difficult to find information about this security module and this video is very complete. Greetings engineer 👍🏿
@bago49
@bago49 3 жыл бұрын
Good vid bro👍 but waving that highly conductive watch next to those high voltage contactors 😅 had me on edge
@yoshisatoshi3206
@yoshisatoshi3206 3 ай бұрын
You'll have a million subscribers in no time. Keep it up !
@samyz1660
@samyz1660 Жыл бұрын
Can you please do a video on a sequence of operation for bigger units, like 10, 20 tons please. I'm a new tech trying to learn . I have subscribed to your channel hoping to gain knowledge. Great channel by the way. Thx to KZbin algorithm who suggested your video.
@andresbarragan8595
@andresbarragan8595 3 ай бұрын
GOOD MORNING FROM CHICAGO THANK YOU SO MUCH
@D2DNYAC
@D2DNYAC 3 ай бұрын
What’s up Chicago , are you guys busy yet?
@OthmanAlikhan
@OthmanAlikhan 2 жыл бұрын
Thanks for the video =)
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thank you for stopping by
@bigbite9804
@bigbite9804 2 жыл бұрын
Instead of Removing wire if you switch off condenser fan high pressure going increase then safety switch work perfectly..in same way if you can close high pressure line value then you get low pressure in that way u can check in real time your low pressure switch work perfectly.. this is how we do .. This is my opinion only ..u are doing great work..
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thanks for stopping by, please check my other video on this subject!
@mithunsha422
@mithunsha422 3 жыл бұрын
Good job bro thx
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thanks for stopping by
@hvacknowledgechannel1621
@hvacknowledgechannel1621 3 жыл бұрын
Nic sharing knowledgeable we should never bypass anyone of them
@Gabriel-vz7ml
@Gabriel-vz7ml Жыл бұрын
Thank you!
@D2DNYAC
@D2DNYAC Жыл бұрын
Thanks for stopping by
@chris198004
@chris198004 2 жыл бұрын
this could have been a 30 second video but very informative
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thanks for stopping by
@brunomelvin4233
@brunomelvin4233 2 жыл бұрын
Yes sir I need thorough expl
@syedbasheer8210
@syedbasheer8210 3 жыл бұрын
Thanks..
@jackbrennan754
@jackbrennan754 3 жыл бұрын
Good information my question is how do you replace a high or low pressure switch without losing your refrigerant charge came across this problem.
@mikhailfraser5280
@mikhailfraser5280 Жыл бұрын
You add a swivel tee
@babaolowo35
@babaolowo35 2 жыл бұрын
Thanks 👍
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thank you for stopping by
@Tokenomics1
@Tokenomics1 Жыл бұрын
thanks!
@D2DNYAC
@D2DNYAC Жыл бұрын
Thanks for watching
@krishnaajaayajayaprakas5475
@krishnaajaayajayaprakas5475 2 жыл бұрын
Thanks bro
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thanks for stopping by
@kashifkerr9309
@kashifkerr9309 2 жыл бұрын
Can you please make a video on understanding pressures?
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Sure thing stay tuned for that
@wdennis8
@wdennis8 3 жыл бұрын
The pressure switches are running through the coil right? It’s a 24v - 240v switch right? Please explain how you hooked up the wiring for the switch. How does it interrupt the contractor?
@D2DNYAC
@D2DNYAC 3 жыл бұрын
I will do another video upload this week on that look out for it
@Yourengineeringstandpt
@Yourengineeringstandpt 11 ай бұрын
Can you tie the hi pressure switch if not one avaliable in a tight spot, sort of like emergency situations
@D2DNYAC
@D2DNYAC 11 ай бұрын
Can I do what ?
@juannanez3969
@juannanez3969 2 жыл бұрын
I just checked for continuity in both my switches. One of them showing there is continuity and the other one showing 400 ohms of resistance. What does that mean? I’m also not getting 24V at the side legs of the contractor, but I am getting the 24V coming from the thermostat.
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Replace the switch with the 400 ohs of resistance I would start there!
@xraybravo7180
@xraybravo7180 Жыл бұрын
Do you know how trane 2 stage packagw unit compressor lockout works ? Apparently I had low pressure got power going in and out however high pressure switch and discharge line snap disk switch didn't have power during compressor lock out.
@D2DNYAC
@D2DNYAC Жыл бұрын
Get me the model number and I can tell you
@AnthonyWilliams-go2tl
@AnthonyWilliams-go2tl 3 жыл бұрын
Hello I'm having problems with a stand up hvac. I didn't open the door on the back for the fans for the condenser to blow out and it shut the unit down. The reading are at 100psi on the blue side of my gauge.Is there any way to get the presure back down so the hbac can come back on.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Not enough information here for me to advise you!
@D2DNYAC
@D2DNYAC 3 жыл бұрын
What manufacturer? What’s the issue or exact problem?
@user-tg6sg6ho4h
@user-tg6sg6ho4h 2 жыл бұрын
Question: When does the high-pressure sensor disconnect the gas 22
@D2DNYAC
@D2DNYAC 2 жыл бұрын
350 to 410 psig depending on the switch
@yanheriherlambang8019
@yanheriherlambang8019 3 жыл бұрын
How to change oil scroll compresor in tandem sytem.? Thanks a lot.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
The easiest way would be to use the oil ports or connecting oil equalizer lines to drain the oils and then refill it through the oil or suction service ports.
@yanheriherlambang8019
@yanheriherlambang8019 3 жыл бұрын
@@D2DNYAC Do you have the video..? I wanna see it.Thank you so much.
@kerrynball2734
@kerrynball2734 11 ай бұрын
All the control circuit is 240V in my AC unit. I'd certainly be taking more care with those connectors an that scenario as they're going to bite a compared to a 24V control circuit.
@D2DNYAC
@D2DNYAC 11 ай бұрын
Agreed
@odeliocepeda6054
@odeliocepeda6054 3 жыл бұрын
In the case of , you come across a bad low pressure switch and don’t have any low pressure switches on hand ,but the unit needs to go up. How do you jump out the switch ? until you go and get a switch
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Shunt or splice together the 2 wires leaving the switch
@odeliocepeda6054
@odeliocepeda6054 3 жыл бұрын
Thanks!
@itsmeagain6168
@itsmeagain6168 3 жыл бұрын
Big up
@theodoe5425
@theodoe5425 3 жыл бұрын
I wanna know more about the time delay.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Okay I will do a video on it or incorporate it into another video. Stay tuned for that
@roopramsoeknandan7601
@roopramsoeknandan7601 Жыл бұрын
I have the same system in my building. So one of my compressor has water inside I had a technician came over telling me that we need to replace a compressor when they come with the new . They told me the heat exchanger has internal leak in there. I just want to know if that’s true
@D2DNYAC
@D2DNYAC Жыл бұрын
Doesn't add up !
@patrickmekus1476
@patrickmekus1476 2 жыл бұрын
Pls i want to know how each of the switches were connected to the system
@D2DNYAC
@D2DNYAC 2 жыл бұрын
the switches are connected in series most of the time!
@ekpenyongakpan149
@ekpenyongakpan149 2 ай бұрын
I want to know how a low and high pressure switch is been connected. Thanks
@D2DNYAC
@D2DNYAC 2 ай бұрын
I have a video uploaded already check it out
@SharifKhan-yz2er
@SharifKhan-yz2er 2 жыл бұрын
Thank you so much
@tafsheeralam9833
@tafsheeralam9833 3 жыл бұрын
Sir i have some issue i instaled compresor nd i try to charge freon but compresor are trip by low pressor switch plss tell me some way to charge freon
@D2DNYAC
@D2DNYAC 3 жыл бұрын
What you should do is place the Freon tank in a bucket of hot water or use a heat gun/ blower to warm up the tank this will allow charging while compressor is off best practice.
@ricardoanguloavila41
@ricardoanguloavila41 11 ай бұрын
Hi there! I have a problem with my Package Unit, the Diagnostic Codes for Defrost control Leds is telling me "HIGH PRESSURE SWITCH LOCKOUT" ...
@D2DNYAC
@D2DNYAC 11 ай бұрын
Are you a hvac technician?
@zeke6150
@zeke6150 Жыл бұрын
Hello sir! Can you make a video searching for leaks in the system? Like the problem is that the unit is not cooling although it's operating? Thank you very much!
@D2DNYAC
@D2DNYAC Жыл бұрын
Okay
@joechambers09
@joechambers09 6 ай бұрын
​@@D2DNYACi have a lennox xp13 system and my green light is blinking showing high pressure fault...my compressor is not coming on and the switch had automatic reset but dint think its resetting...what can i do to reset it
@brunomelvin4233
@brunomelvin4233 2 жыл бұрын
Sir please make vedio on career package Ac using two compressors and the wiring diagram for the lock out relay wiring . Please explain how it's wired and how it works.
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Hello friend Do you want to know how the lockout relay works and wired?
@brunomelvin4233
@brunomelvin4233 2 жыл бұрын
@@D2DNYAC yes sir I need a vedio thoroughly explaining how the lock out circuit works employing two compressors and two lockout relay for two circuits. I am asking you from Bahrain Another vedio on Big career split Ac indoor unit staring with DOL starter wiring diagram. Please I hope you help sir.
@kellesaereanque2131
@kellesaereanque2131 Жыл бұрын
Is it possible to replace the high pressure switch into one that can be adjustable
@D2DNYAC
@D2DNYAC Жыл бұрын
Yes
@kellesaereanque2131
@kellesaereanque2131 Жыл бұрын
@@D2DNYAC thank you so much
@ras2820
@ras2820 3 жыл бұрын
So high pressure switch is pressure is fine the switch remains closed once pressure gets to high switch opens??
@D2DNYAC
@D2DNYAC 3 жыл бұрын
👍 yes
@joechambers09
@joechambers09 6 ай бұрын
​@@D2DNYACis there a way to measure if the high pressure switch is open on a automatic switch
@dbc105
@dbc105 5 ай бұрын
What switches are you using andd where are you getting them?
@D2DNYAC
@D2DNYAC 5 ай бұрын
The switch pressure cut in and cut out rating depends on the refrigerant
@D2DNYAC
@D2DNYAC 5 ай бұрын
Refrigeration or hvac supply house or shops or on the internet
@terranhealer
@terranhealer 10 ай бұрын
I have a code 35 error which means a low pressure switch or sensor error. My system doesn’t have a leak though. Is there a way to bypass this faulty switch or sensor?
@D2DNYAC
@D2DNYAC 10 ай бұрын
What system?
@terranhealer
@terranhealer 10 ай бұрын
@@D2DNYAC it's an LG mini split
@patrickl3625
@patrickl3625 2 жыл бұрын
Please Please Please D2D NY … Can you Explain ( What is Restriction T.X.V valve) to Troubleshooting
@D2DNYAC
@D2DNYAC 2 жыл бұрын
The TXV creates a controlled pressure difference between the high and low side of your refrigeration system as refrigerant flows through it, when the TXV is restricted that pressure drop becomes uncontrollable thus starving your low side/evaporator of refrigerant Symptoms is low back pressures, most times high head pressure, high suction line temperatures/ super heat, high supply air temperature, poor cooling. Solution replace the valve
@patrickl3625
@patrickl3625 2 жыл бұрын
Can you please shown the video how to troubleshooting The TXV valve restriction
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Okay stay tuned
@MangoEnchilada-
@MangoEnchilada- Жыл бұрын
Will the condenser fan still run if the pressure swith trips?
@D2DNYAC
@D2DNYAC Жыл бұрын
In some cases yes especially carrier RTU units
@MangoEnchilada-
@MangoEnchilada- Жыл бұрын
I have a lennox 13acx-036-230 13. The entire unit runs and turns on, but it blows hot. Im thinking low refrigerant?
@La2venida
@La2venida 3 жыл бұрын
Question: could I bypass the pressure switch, charge the system, and just leave it jump?
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Sure, however that’s dangerous to anyone who operates this system and to the system it self, so please don’t
@La2venida
@La2venida 3 жыл бұрын
@@D2DNYAC why would it be dangerous to one that operates...are there system s that don't have pressure switchs
@HelloThere-jr6gd
@HelloThere-jr6gd 3 жыл бұрын
Because if your system does pull a high head pressure or a very low suction pressure the system wont shut off and it will ruin your compressor. Only bypass it if its temporary and you are coming back to fix it later. Dont leave it bypassed.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
It’s not dangerous to one that operates however if you bypass the high pressure switch you can definitely ruin your compressor bypassing the low pressure switch isn’t too bad however you can still ruin your compressor if the system freezes up and slug liquid refrigerant back to compressor. If you must only do it during troubleshooting or in an emergency if the switch or switches is faulty and system pressures are okay. And return and remedy ASAP.
@sheeesh3355
@sheeesh3355 2 жыл бұрын
What should i do if there is no manual reset on pressure switch
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Nothing this means the switch will automatically reset once the pressures come down
@joechambers09
@joechambers09 6 ай бұрын
​@D2DNYAC how do you get the pressure to come down
@justinhinds4388
@justinhinds4388 Жыл бұрын
I want to know what capacitor and transformer does?
@D2DNYAC
@D2DNYAC Жыл бұрын
Transformer lower the incoming line voltage to control voltage 460/208/120 volts to 24 volts, capacitor is used on single pashas motors/ compressors to increase starting and running power
@tserevenad
@tserevenad 2 жыл бұрын
My compressor won't run, won't make a noise. wondering about pressure switches. But, condenser fan does run, thus contactor working. If my logic is right, per your video, my pressure switches must be ok. worth noting I have a defrost board could that matter. thanks.
@D2DNYAC
@D2DNYAC 2 жыл бұрын
@Tserevenad if you have a residential split system and the fan on top of the outdoor unit spins, and compressor doesn’t run it seems like your compressor is bad!
@D2DNYAC
@D2DNYAC 2 жыл бұрын
In this case for 1PH units a hard start kit my help!
@tserevenad
@tserevenad 2 жыл бұрын
@@D2DNYAC yes I have a stains you describe. I used my ohmmeter to check coil winding. Shorts to ground and a stuck overload switch. Everything perfect. Can compressor be bad if electrical tests are good. Doesn’t blow fuses either. Also cap and contractor measure/working properly. I am thinking something going on with defrost board and sensor but not clear on why it would make compressor not run. Thanks for your thoughts.
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Then if this is the case typically the fan and compressor shares the same contactor the compressor 1PH compressor is seized, try using a hard start kit /capacitor sometimes this will get compressor going, you can also send me a picture of your ac unit and wiring diagram on (what’s app) so I can better assist!
@tserevenad
@tserevenad 2 жыл бұрын
@@D2DNYAC appreciate your help. I just reread my last text and it is nonsense so I need to give you correct info. I need to setup WhatsApp on my phone and reach out to you again this afternoon. Thanks.
@user-ge9on2zz4g
@user-ge9on2zz4g Жыл бұрын
How do you know if the pressure sensor is broken or working?
@D2DNYAC
@D2DNYAC Жыл бұрын
They are typically normally closed switches, when system pressure is good, and opened if faulty or if system has a problem
@user-ge9on2zz4g
@user-ge9on2zz4g Жыл бұрын
@@D2DNYAC Under normal circumstances, is there electricity at one corner or both corners?
@mohammadfahimnaimi4222
@mohammadfahimnaimi4222 Жыл бұрын
Brother I need help, my ax unite has a bad high pressure switch how can I replace it and where I can buy it I really need a little help
@D2DNYAC
@D2DNYAC Жыл бұрын
Where are you located ?
@mohammadfahimnaimi4222
@mohammadfahimnaimi4222 Жыл бұрын
@@D2DNYAC Arizona
@D2DNYAC
@D2DNYAC Жыл бұрын
Hvac supply store, don't know what's in Arizona!
@D2DNYAC
@D2DNYAC Жыл бұрын
You will need to know what refrigerant system uses and you can purchase a swivel tee as well and follow my method
@Toylakwatsero
@Toylakwatsero 2 жыл бұрын
What is the purpose of contactor sir?
@D2DNYAC
@D2DNYAC 2 жыл бұрын
@ abet lakwatsero It is an electronic switch which is controlled by your thermostat , the thermostat passed low or controlled voltage usually 24V to the contactor coil then the switching section of contactor then pass high voltage to the load compressors and fan motors to put it simply, it can get more complex
@Toylakwatsero
@Toylakwatsero 2 жыл бұрын
@@D2DNYAC Thank you for information sir God Bless
@ras2820
@ras2820 3 жыл бұрын
Is the high pressure switch the same as the high pressure control
@D2DNYAC
@D2DNYAC 3 жыл бұрын
No!
@ras2820
@ras2820 3 жыл бұрын
@@D2DNYAC ok so if you don't mind me asking what is the high pressure control thank you?
@D2DNYAC
@D2DNYAC 3 жыл бұрын
😂 a device that controls the head pressure. There is various types I have a video on type of head pressure control device! I will link it below👇🏻👇🏻👇🏻video
@D2DNYAC
@D2DNYAC 3 жыл бұрын
HEAD PRESSURE CONTROL VALVE / HPCV/ HEAD MASTER HOW TO INSTALL & WHAT IS IT?
@D2DNYAC
@D2DNYAC 3 жыл бұрын
In my video title above is one type of head pressure control device. Examples of others are Variable frequency drives, fan cycling switches, motorized dampers, motorized valves
@janjantagud9918
@janjantagud9918 3 жыл бұрын
How to by pass high pressure switch?
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Don’t recommend this unless you are troubleshooting!
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Don’t recommend unless troubleshooting , however you can bypass by cutting both wires connected to the switch, then strip and connect both wire going back into the controls together
@janjantagud9918
@janjantagud9918 3 жыл бұрын
But the pressure switch has three wires... 😭
@theodoe5425
@theodoe5425 3 жыл бұрын
I wanna know more about the time delay
@aripapari9226
@aripapari9226 Жыл бұрын
Can I call you for service? I’m in queens NY
@D2DNYAC
@D2DNYAC Жыл бұрын
Sure thing
@lyotoarellano
@lyotoarellano 2 жыл бұрын
Do you respond to questions?
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Always
@D2DNYAC
@D2DNYAC 2 жыл бұрын
What’s yours?
@danielobethlopezdelgado5059
@danielobethlopezdelgado5059 Жыл бұрын
Acapulco
@D2DNYAC
@D2DNYAC Жыл бұрын
English
@dwmcever
@dwmcever 3 жыл бұрын
Worked in refineries and chemical plants most of my life, you're not allowed to wear watches or rings of any kind or Jewelry period . Doesn't matter your rank or craft. Those Blue Gloves and grabbing HOT WIRES are going to get this guy killed. Yes I am an expert, Senior V.P. Engineering (retired). Couldn't get past the safety issues here to watch the video for content. Had he been one of my employees he would have been suspended until he attended required safety classes.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Hey 👋 thanks for stopping by! 🤔l understand and knows all the risks involved with the job however things are different inside of a plant that’s a controlled environment out here in HVAC you are going to have to troubleshoot live circuits and I have yet to see anyone got suited up to do so., I am a pro and knows and understand what I am doing and I can assure you after 17 yrs in the industry I will not be killed by the HVAC trade craft🤫😂
@PBS-nm1uu
@PBS-nm1uu Жыл бұрын
bad camera angle
@D2DNYAC
@D2DNYAC Жыл бұрын
What didn't you not see ?
@donttalktome9528
@donttalktome9528 4 ай бұрын
Jamaican.
@D2DNYAC
@D2DNYAC 4 ай бұрын
💯🇯🇲
@SateeshMaurya-xv4dm
@SateeshMaurya-xv4dm 9 ай бұрын
Sir please language in Hindi use
@D2DNYAC
@D2DNYAC 9 ай бұрын
Thanks for watching
@jessuezhernandez1991
@jessuezhernandez1991 Жыл бұрын
My A/C works but the won't switch over to blow out heat? What could be the issue? We had someone come change out our pressure switch and The heater went out... any tips or advice you can give me ? I'd appreciate it
@D2DNYAC
@D2DNYAC Жыл бұрын
In the case of a heat pump it’s either the thermostat configuration/wiring or a bad reversing valve in the case of other heating systems type pressure switch on AC would have no impact on heating
@danielobethlopezdelgado5059
@danielobethlopezdelgado5059 Жыл бұрын
Acapulco
@D2DNYAC
@D2DNYAC Жыл бұрын
English please
How HVAC Refrigerant Pressure Switches Work & Troubleshooting!
19:13
AC Service Tech LLC
Рет қаралды 162 М.
How to Properly Diagnose a Failed TXV
31:47
HVAC School
Рет қаралды 585 М.
A clash of kindness and indifference #shorts
00:17
Fabiosa Best Lifehacks
Рет қаралды 129 МЛН
🤔Какой Орган самый длинный ? #shorts
00:42
World’s Largest Jello Pool
01:00
Mark Rober
Рет қаралды 57 МЛН
Now THIS is entertainment! 🤣
00:59
America's Got Talent
Рет қаралды 40 МЛН
Testing Pressure Switches on Condensing Units
4:38
Tec Tube
Рет қаралды 104 М.
How to Read SUPERHEAT and SUBCOOLING
11:43
Word of Advice TV
Рет қаралды 584 М.
TROUBLESHOOTING, DIAGNOSTICS AND RESOLUTION OF A HVAC OR AC UNIT ON A SERVICE CALL
26:38
D2D NY Real World HVAC Simplified
Рет қаралды 63 М.
AC Contactor Not Pulling In - 10 Reasons Why
14:16
Word of Advice TV
Рет қаралды 838 М.
High Pressure, Cause and Effect. EP28
7:54
Nighthawk HVAC
Рет қаралды 10 М.
HVAC  076 Pressure Switch Refrigerant
16:34
Love2HVAC with Ty Branaman
Рет қаралды 41 М.
AC Repair Replacing Hi Pressure Switch
7:51
The HVAC Hacker
Рет қаралды 138 М.
Multi-zone split type Air Conditioner installation
16:49
craftsman tv
Рет қаралды 328 М.
Refrigeration: Low Pressure Control As Temp Control
25:22
Christopher Molnar
Рет қаралды 89 М.
Troubleshooting a Faulty Low Pressure Cutout on a Residential AC
7:56
Interplay Learning Interactive Training
Рет қаралды 56 М.
A clash of kindness and indifference #shorts
00:17
Fabiosa Best Lifehacks
Рет қаралды 129 МЛН