Too good. 👍🏻 perfect. Excellent explanation without saying a single word. Bravo 👏🏻👏🏻👏🏻
@basheeralkayyal37793 жыл бұрын
Very simple and straightforward, Thank you very much.
@LSmith2k3 жыл бұрын
Thanks this helps a lot for my capstone project
@jansenspanzu40833 жыл бұрын
Thank you very much, it is something that I needed really.
@hemantsutar70343 жыл бұрын
This video has very much useful but voice is required when it explains the logic of PLC
@seabelekgowe99584 жыл бұрын
I need this set for my practice. - 3 phase motor 0.75-1.2 kw - VFD 1ph to 3ph output 220/380 - Simatic S1200 PLC - Push buttons and indicators light -
@ATOcom4 жыл бұрын
ATO 3-phase motor 0.75kW link, www.ato.com/1-hp-0-75kw-3-phase-4-pole-ac-induction-motor 1.1kW link, www.ato.com/15-hp-1-1kw-3-phase-4-pole-ac-induction-motor ATO 1-phase to 3-phase VFD link, www.ato.com/single-phase-to-three-phase-vfd ATO indicators light link, www.ato.com/alarm-siren We don’t have any others for now.
@alikhanzulkashov44383 жыл бұрын
As far as I understood you have sourcing DI and sinking DO?
@Dc_tech3862 жыл бұрын
A lot of people don’t realize how special vfd or it’s save money on electricity bill with its soft startup that cut out the high wattage on any ac induction until and I mean any induction device vfd should be in every house
@divyajyothi38343 жыл бұрын
Thank you, nice video, I need real-time wiring connection video, please provide this.
@anjelcosta48392 жыл бұрын
Thank you. Why you used here stop holding ?
@shivsrikakolum2100 Жыл бұрын
it is actually a three wiri control wiring on VFD where Digital input 3 should alwyas be high if DI3 is not high/ON then fwd and reverese action wont happen
@olcayozalan49262 жыл бұрын
ooh thanks from Turkiye. it was very useful to comprehend
@kevin008612 жыл бұрын
Woow, that was very very informative! Thanks a million times, yes, I've this short question please, @ 04:39 the VFD terminal on the left, three terminals are labeled TA/TB/TC; what are they for, i know i should check the wiring diagram but i do not have one I do highly appreciate your reply
@ATOcom2 жыл бұрын
Alarm output terminal of VFD.
@Brian_Banda.4 жыл бұрын
Thank you for your insightful videos👌
@dienau63134 ай бұрын
This is a great appication, may I ask? How will the above system be applied to the plastic recycling industry? I am a senior student studying a graduation topic related to this profession
@shivsrikakolum2100 Жыл бұрын
I want to ask a question ... have you used an ALL TIME High bit on Power oN to start timer? because i cannot see physical input to pLC.
@luckychohan37052 жыл бұрын
Hi I have just completed my apprenticeship In Canada I wish could practically learn from u where are u from sir ?
@yewjieh38972 жыл бұрын
Are you using a 240VAC coil relay or a 24VDC coil relay?
@ATOcom2 жыл бұрын
24VDC
@abdulwahab-x9o Жыл бұрын
What comunication protocol use to DCS?
@carlosbah462310 сағат бұрын
Good content. Useful channel ! Subscribed. ¡Gracias por compartir!
@phillipdevillephysics909611 ай бұрын
Hello, I am new to technology and wanting to build this demo with my students. Though we have access to 240 V and 480 V, I am wanting to modify this build for 110 V from the wall. If there is a reason not to do this, please let me know. I do not see voltages/currents specified in the video. I am trying to figure out the specs of the contactor/relays that will be necessary here. If you are using 220 V system, the voltage between L and N is 120 V, so that is the coil voltage in that case I should look for in the 3P NO contactor? I can find a VFD that is single-phase 110 V to 3-phase 220 V, and I have general purpose 220V 3 phase motors in the lab; the one I am planning to use is 5.2 A at full load. The switching power supply is no problem to obtain. The PLC I am wanting to use is an Allen Bradley 1200 MicroLogix that requires 110 V to power, so I was going to branch off from the circuit breaker to the PLC. Do you have a circuit breaker you would recommend with 6 pathways? Those MY2N relays are 24 V DC, I am assuming, can it be possible to use 8 pin DPDT relay from the ATO website for this? I am still learning as well, so please forgive any ignorance.
@phillipdevillephysics909611 ай бұрын
If you are sticking to US color code, the blue and red wire is L2 and L3 and there is 208 volts across there. Please help me get started in the correct direction.
@ATOcom11 ай бұрын
1. It is OK for you to use your wall voltage of 110V for demonstration (this depends on your VFD input voltage); 2. Control the 24VDC relay through the output of the PLC, and then use the 24VDC relay to control the contactor KM (hazardous voltage, AC) of the main circuit; safe voltage controls hazardous voltage, which is a common practice in industrial settings. You said that you have a VFD from single-phase 110V to 3-phase 220V. Therefore, you can imitate my case and determine the coil voltage KM of the contactor as 110V. This degree of freedom is great. Of course, if your other power sources allow it, you can choose the voltage to be 24VDC, 240VAC, 208VAC...etc. 3. Your PLC uses 110V voltage, which can also be obtained from your wall voltage. But please be sure to note that your PLC output terminal is 110V? Or 24VDC? I haven't used your PLC specifications, so you can only check it yourself. 4. You can use any relay with NO and NC functions. The prerequisite is that your relay can load the contactor coil power and can open or close the control terminal of the VFD. And your relay coil voltage matches your PLC output voltage. 5. In my case, the blue and green wires are just to differentiate between live and neutral wires. There are various voltages. The voltage in your project depends on your VFD input voltage, PLC input voltage & output voltage. You need to figure out the operating logic of this project to determine what specifications of components are beneficial to you.@@phillipdevillephysics9096
@phillipdevillephysics909611 ай бұрын
Wow, thank you for the time spent in providing this detailed answer! The PLC is 24 V logic outputs. I am still learning these devices, but your guide is very helpful. @@ATOcom
@phillipdevillephysics90969 ай бұрын
@@ATOcom Thank you. The PLC I am using has relay outputs so I can use 110 VAC or 24 VDC. This has been a tremendous project to learn on, however, I must say I am much more used to sinking inputs and sourced outputs.
@teammouse Жыл бұрын
Is there also a vfd for 3ph 240v input to 3ph 240v output or can I just use the 380v 3ph one on our 240 lines?
@ATOcom Жыл бұрын
yes, this link, www.ato.com/3hp-vfd-three-phase www.ato.com/3-hp-vfd-1-phase-220v-to-3-phase-380v
@teammouse Жыл бұрын
@@ATOcom oh thank you very much!
@masumahmed2142 Жыл бұрын
program can not see,can u give me the pdf file of ur program.Thanks advance
@yourvitamin947411 ай бұрын
What kind of PLC Model and What?
@Technicalsaad43912 жыл бұрын
Complete cost of this project ?
@z_review52472 жыл бұрын
Hello, where can we get this programm?
@ATOcom2 жыл бұрын
Check out the description section for more info.
@mohammadramxan16363 жыл бұрын
I installed the inverter with 2hp single to 3phase,motor making noise and vibration. what should me do?
@ATOcom3 жыл бұрын
If you are buying our Inverter (VFD), please contact our after-sales team by email: www.ato.com/contactus
@sweeetboy19073 жыл бұрын
3. where does the Phase come from?
@MistaWhatchaKnow3 жыл бұрын
The VFD should provide the phase change for the motor. It is single phase into the VFD and three phase out for this motor.
@manishchaudhari46082 жыл бұрын
Vfd ke sath plc important hai kay
@hsyn.mo49 ай бұрын
great video you made. Thanks alot ❤❤🎉🎉🎉
@joew42023 жыл бұрын
Can you give advice how to set up single phase motor in my house for learning purposes. I have a click plc
@BitKing_Ross3 жыл бұрын
Yes agree. I want to know how to use a CLICK plc to control ATO vfd.
@electricalmaintenanceteam77022 жыл бұрын
Good job
@radoslavradoslavov35282 жыл бұрын
Thank you bro!
@radoslavradoslavov35282 жыл бұрын
And music is also good.
@rajbudha49127 ай бұрын
Motor ka spet badane ka bata vand hojata he yes ka kay karne paryaga
@rachakondagowtham5112 жыл бұрын
Nice But if we have audio insted of text By the way nice , Thanks
@class8math2 жыл бұрын
Omron plc me input ke liye kahi 0.00 aur kahi i0.00 kyon lete hai Isi tarah output me kahi 100.00 aur kahi Q100.00 kyon lete hai Please tell
@ATOcom2 жыл бұрын
I don't quite understand what you mean.....
@class8math2 жыл бұрын
@@ATOcom may I got your whats app number or phone number
@HHafis-ik2rv4 жыл бұрын
Thank you ...
@chsai92642 жыл бұрын
Broo, can I get document for this project it's very urgent brother.
@ATOcom2 жыл бұрын
Everything you need is in the video, thank you for your message.
@1stpagpaguitanjonel1765 ай бұрын
Hi sir Wala po ba kayo tutorial Ng Video na ito???
@GasLightyear693 жыл бұрын
Thank you
@ChidiEmelobe-yv6vk2 ай бұрын
Thank you for sharing. I would choose voice explanation to this background music
@mehmetbuyukcakir9372 Жыл бұрын
Are the outputs negative logic?
@mohammadkrera17778 ай бұрын
Thank you Name app
@tariqueazamjamali27933 жыл бұрын
How many prise?
@ATOcom3 жыл бұрын
Price link, www.ato.com/vfd
@framos99913 жыл бұрын
Thanks!!!
@robinsoncrusoe2775 Жыл бұрын
I would say the old contactor phase changer is way better mode for reverse then this
@ATOcom Жыл бұрын
That's right, sometimes such a complex video isn't needed.
@electricalinpractical37174 жыл бұрын
Plz make a video on fatek plc for star delta connection ....
@ATOcom4 жыл бұрын
This link, kzbin.info/www/bejne/fpbQiq2QhLJ9pNU But, If your motor has a delta connection and the power supply voltage is 380V, the voltage will become 660V after changing to star (Y). So please protect your motor.
@tharindubandara42962 жыл бұрын
Great
@ransagark.c30393 жыл бұрын
Plc k jyada video banao plzzz plzz
@AgnesCarpenter-p1o2 ай бұрын
Allen Nancy Hernandez Robert Rodriguez Angela
@DoraSpring-m9o3 ай бұрын
Moore Brian Martinez Sharon Thomas Joseph
@salarbadeel44713 жыл бұрын
nice
@vikasrao74333 жыл бұрын
Please speeak Hindi
@neighberzhang3513 Жыл бұрын
We are an aviation plug factory, if you need to contact me