For the overturning of the wall, is the idea that the strip footing is used to resist overturning from the shearwall? If so, then you wouldn't need holdown footings at your holdown location? How does this work if your holdown is creating a point load on the footing? How would you fully engage the full length of the strip footing for this? You can't realistically say a 30' long strip footing resists the uplift that occurs as a point load at one end of the footing. Am I missing something here?
@annakochetkova39622 жыл бұрын
I just want to say thank you for the great videos! Very straightforward and simple explanation!
@Kestava_Engineering2 жыл бұрын
You're very welcome!
@User-gd6sd Жыл бұрын
Is the 5 kip wind load an ultimate wind load? If there are no factors applied in the global stability check, but we are using service loads, does that mean we would use a Service Wind load = 0.6*Ultimate wind, or Service Seismic load = 0.7*Ultimate seismic load.
@Kestava_Engineering Жыл бұрын
yes - the wind loads derived in the ASCE 7 are strength level forces. so the 0.6W "load case" is bringing strength level wind back to service level wind. same with seismic
@MohamedHaji-k5j10 ай бұрын
Thank you mr.kestàvà. truly appreciate your videos.
@perfectbasics23811 ай бұрын
Thank you for this Video, Just one question, while checking sliding, you just compared dead load with lateral force. It should have load combinations, e.g. 0.6D+0.7E for ASD.
@Kestava_Engineering11 ай бұрын
you are absolutely correct!
@mr.d3916 Жыл бұрын
So if the shearwall has large overturning moment because of height, the wall footing will not be adequate, right? You need to use deep foundation?
@migueldlima400511 ай бұрын
What we need to design when we finish this calc, would you mind giving me a list. Thanks
@Kestava_Engineering11 ай бұрын
I have a few other videos that go into the design of the shear walls! check them out!
@mateogonzalezmolina8997 Жыл бұрын
Where did you get the safety factors?
@louispuccio1161 Жыл бұрын
What if it is a foundation wall that is burried? Say an 8 below grade wall? Do you incorporate the passive soil forces induced? Or would u design from the bottom of the sill plate upward?
@KM-zv8zi7 ай бұрын
If there is no soils report the lowest value can be used in chapter 18 of the building code which gives 0 for the friction factor, but rather a cohesion and a 1,500 psf bearing pressure for the soil. I have also not seen the weight of the footing for the resisting moment and the height of the footing is also not considered, just the height of the SW itself (10 ft in this case) also the dead load is to be multiplied by a factor which varies based on the seismic design criteria. But overall a conceptually great demonstration.
@arturzych138 Жыл бұрын
Question: the moment of resistance for overturning is it not located at the center of gravity of the wall & strip footing, and the force being the self-weight of the structure (wall & footing)?
@luisdelcid705110 ай бұрын
Do you know how to design colt shearwall with multiple opening and high aspect ratio panel with spline connectors and angle brackets as well as hood downs?
@Kestava_Engineering10 ай бұрын
I am not familiar with a "colt" shear wall? can you explain further?
@luisdelcid705110 ай бұрын
@@Kestava_EngineeringI’m sorry I meant CLT SHEAR WALL with spline connectors and Hold Downs
@TAMBAMoiCartay Жыл бұрын
Are the 5 kips coming from the roof dead load / uniform load
@Kestava_Engineering Жыл бұрын
its lateral loads induced by wind load. good question!
@structureclass28294 жыл бұрын
Is it typical to neglect soil weight above footing for overturning moments? Is it similar to reasoning for neglecting passive pressure over toe of a retaining wall?
@Kestava_Engineering4 жыл бұрын
Hi Logan, Both can be included in your design if you need to "sharpen the pencil". Both are absolutely correct to use in your design, and we typically like to use these if there are late changes in a project that cause us to push the limits of our design without resizing footings.
@Kestava_Engineering4 жыл бұрын
obviously if the footing geometry is large and supporting a large volume of soil then we would want to include that. Many designs are completely custom and should be evaluated and designed using good engineering judgement.
@migueldlima400511 ай бұрын
Do you have a group to teach them or something like that?
@Kestava_Engineering11 ай бұрын
just my experiences and things I've learned / been taught along the way of m career so far!
@TV-ws8mf4 жыл бұрын
Can you send me the link to how to calculate 5 kips lateral force on shear wall tip?
@Kestava_Engineering4 жыл бұрын
kzbin.info/www/bejne/qJ64i2iDe9p6e6M
@Kestava_Engineering4 жыл бұрын
is that what your looking for?? just let me know if you need something different and ill do my best!
@TV-ws8mf4 жыл бұрын
@@Kestava_Engineering 1:20 You said you are not going to cover how to get 5 kips in this video.
@fathullahzamani68682 жыл бұрын
Thanks!
@Kestava_Engineering2 жыл бұрын
No problem! and thank you for the super thanks! I really appreciate the support
@habibsabzezar68462 жыл бұрын
Please make more wood structural engineering
@Kestava_Engineering2 жыл бұрын
you know it! more coming
@piesta2 жыл бұрын
thank you
@Kestava_Engineering2 жыл бұрын
You're welcome!
@jeffsupran37292 жыл бұрын
what video shows you how to find the 5Kip load at the top of the wall.
@Kestava_Engineering2 жыл бұрын
I have some newer videos where we determine lateral loading on a structure! check out my wood diaphragm video!
@jeffsupran37292 жыл бұрын
My question is: how do you get to the 5 kip force if is not given to you in the problem
@Kestava_Engineering2 жыл бұрын
i go over finding lateral demand in some of my newer videos Jeff! check out the design of wood diaphragm!
@asptanominations75564 жыл бұрын
Can you also please do a video on design of shear wall with the hold downs.
@Kestava_Engineering4 жыл бұрын
absolutely! coming right after the 3 part lesson on seismic design
@asptanominations75564 жыл бұрын
@@Kestava_Engineering Thank you! Looking forward to part 2 and 3 lessons on seismic design.
@aboudeh219 ай бұрын
why there isn't Live Load ?
@Kestava_Engineering9 ай бұрын
I didnt include it to keep the problem simple. But if you have live load (often times you do) then you need to apply the proper load combinations! great question
@aboudeh219 ай бұрын
also if you can explain what is qref? I mean, as far as I know, we should compare qmax and qmin to qref, right ?@@Kestava_Engineering
@structureclass28294 жыл бұрын
Also, not sure if they apply for shear walls, but I typically use International Building Code sections 1806 and 1807 for factors of safety, soil sliding friction constant, and assumed bearing capacity if we don't have a geotech report.
@Kestava_Engineering4 жыл бұрын
I did not mention IBC, and i should have! The IBC is a great resource to obtain these values.
@daviddesomma249 Жыл бұрын
Thanks!
@Kestava_Engineering Жыл бұрын
thank you so much David! very very much appreciate you supporting the channel !