Relative Response Factor (RRF) is a critical analytical parameter widely used in chromatographic procedures to quantify impurities in drug substances and dosage products. This video describes the estimation of RRF.

Пікірлер: 37
@mohsentalebi9505
@mohsentalebi9505 5 ай бұрын
Keep up the good job. Your videos make the SOPs and ICH guidelines easier to understand.
@manishpandey7112
@manishpandey7112 Жыл бұрын
Nice explanation and more informative. Thanks
@SearchforSomething
@SearchforSomething 2 жыл бұрын
Thanks a lot sir for your valuable and informative video.
@venkat5098
@venkat5098 Жыл бұрын
Thank you so much sir . good explanation easy to understanding thank you sir.
@tamngoc9394
@tamngoc9394 Жыл бұрын
Thanks so much, your presentation is fantastic
@amitnarayankar
@amitnarayankar Жыл бұрын
Can you please make a video on what is recovery and spiking concept in analytics. Thanks
@manusriRaaz2325
@manusriRaaz2325 2 жыл бұрын
thankin you sir for making very usefull videos like these ....
@cbsingh-yn1bn
@cbsingh-yn1bn Жыл бұрын
Very helpful video sir
@shara603
@shara603 2 жыл бұрын
Thanks for making this video sir,,Much needed one.please make video on hplc content method development.
@naceranaci4139
@naceranaci4139 Жыл бұрын
Thank you very much
@suyoggosavi117
@suyoggosavi117 2 жыл бұрын
In calculation formula for known impurities why taken 1/RRF.... Why not take only RRF
@rajilakshmi5133
@rajilakshmi5133 4 ай бұрын
When do we calculate RRF? Is there any criteria? In area normalization method can we calculate RTF?
@prasannakumar1614
@prasannakumar1614 8 ай бұрын
I have confusion on preparation of solutions ,
@janhavivartak9306
@janhavivartak9306 2 жыл бұрын
Thank you sir for providing us with lot of interesting stuff. I had a question in RRF. How do you decide the concentration (ppm) of impurities and API before plotting the linearity graph? Please explain. Thank you.
@pharmagrowthhub3083
@pharmagrowthhub3083 2 жыл бұрын
conc of an impurity and API which lies in the linear range
@AliRaza-wp8tr
@AliRaza-wp8tr 2 жыл бұрын
Sir if u are selecting linear range concentration than why slope is not coming equal to 1
@rajeshgoud1274
@rajeshgoud1274 Жыл бұрын
Considering the Specification of Known impurities and unknown impurities and established LOQ concentration, Linearity will be performed to establish RRF
@AliRaza-wp8tr
@AliRaza-wp8tr 2 жыл бұрын
I have two question plz answer Is impurity is running on different HPLC and is it running on lambda max of impurity Why impurities not shows linear response as API do
@gkiran3504
@gkiran3504 3 ай бұрын
Hello sir Present iam doing RRF for one of my project. But didn't get correct RRF. Then what can i do.. please give me advise...
@zankarshah6834
@zankarshah6834 2 жыл бұрын
If limit of unknown impurity and known impurity different at that time linearity and range is also different. So why it is necessary to use same Conc. Level for determination RRF by Slope Method??? Can I use different level of impurity and API as per linearity of respective impurity???
@vangalathirupathireddy6930
@vangalathirupathireddy6930 2 жыл бұрын
Tnku sir ji
@MrKrish1029
@MrKrish1029 2 жыл бұрын
We should cover specifications range concentration for impurities then how can we prepare both sample and standard with same concentration This is my doubt sir
@ask5755
@ask5755 2 жыл бұрын
Why the concentration should be same ?
@kalavalakhageshwarrao5370
@kalavalakhageshwarrao5370 2 жыл бұрын
Sir concentration in PPM or mg/mL
@fooddelight4057
@fooddelight4057 2 жыл бұрын
You must use chrmatogram to demonstrate it would be more effective
@suryaprakashrai3263
@suryaprakashrai3263 2 жыл бұрын
Hello sir, thanks for the video. I have a doubt regarding the consideration of salt and base form. If my API is in salt form then should I need to use factor of base and salt for RRF calculation of impurities?
@rajeshgoud1274
@rajeshgoud1274 Жыл бұрын
Hi brother, If your analyte is in Salt form, convert to base form using correction factor, then using your base analyte concentration, establish RRF of impurities
@sureshkandagatla6126
@sureshkandagatla6126 Жыл бұрын
kindly show how to calculate % recovery using RRF
@hemantchauhan1219
@hemantchauhan1219 2 жыл бұрын
Sir, The Impurity A and API Stock are taken 20 mg and diluted to 100 ml respectively. Than how their concentration is 193.4 and 199 ppm respectively??. Please explain in detail sir.
@m4madhubabu759
@m4madhubabu759 Жыл бұрын
You have to consider potency of respective imp and API... I.e 20/100*96.7/100*1000=193.4
@tamngoc9394
@tamngoc9394 Жыл бұрын
Their potency are different. You have to take potency into account for accurate concentration.
@sagardhimdhime6771
@sagardhimdhime6771 Жыл бұрын
How calculate conc.of imp.A..
@muddy_slipper
@muddy_slipper Жыл бұрын
What is API?
@sagardhimdhime6771
@sagardhimdhime6771 Жыл бұрын
20mg diluted 100ml that is 200ppm ...so
@prasannakumar1614
@prasannakumar1614 8 ай бұрын
Potency works
@sagardhimdhime6771
@sagardhimdhime6771 Жыл бұрын
193.4 ppm where's come
@tamngoc9394
@tamngoc9394 Жыл бұрын
the potency is different
How To Determine Detection Limit (LoD) and Quantitation Limit (LoQ)
22:27
Pharma Growth Hub
Рет қаралды 46 М.
Why acetonitrile has more elution strength than methanol in RPLC?
13:26
Pharma Growth Hub
Рет қаралды 5 М.
Before VS during the CONCERT 🔥 "Aliby" | Andra Gogan
00:13
Andra Gogan
Рет қаралды 10 МЛН
Running With Bigger And Bigger Feastables
00:17
MrBeast
Рет қаралды 166 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 17 МЛН
You must know these facts about the Diluted Standard Method for RS by HPLC
17:12
Challenges during HPLC method development and how to fix them
32:14
Pharma Growth Hub
Рет қаралды 18 М.
Gas Chromatography: Accounting For The Detector Response Factor
15:26
3 common interview questions on Forced Degradation
21:14
Pharma Growth Hub
Рет қаралды 20 М.
How to conduct forced degradation study?
20:04
Pharma Growth Hub
Рет қаралды 18 М.
Why use GLASS WOOL in the GC inlet liner?
9:32
Pharma Growth Hub
Рет қаралды 7 М.
A Guide For Selection of Buffer for HPLC
19:07
Pharma Growth Hub
Рет қаралды 20 М.
Strategies for HPLC Method Development - Webinar Recording
50:51
Mourne Training Services Ltd
Рет қаралды 23 М.