Why use GLASS WOOL in the GC inlet liner?

  Рет қаралды 6,456

Pharma Growth Hub

Pharma Growth Hub

Жыл бұрын

Gas chromatography works mostly for vaporized compounds. The vaporization of the analyte inside the injector port or inlet liner must be consistent and reliable.
How “Glass Wool” can help in making the vaporization process more consistent, and reliable?
Let us explore…
Join the WhatsApp group of Pharma Growth Hub and receive more updates: chat.whatsapp....
Regards
Bhaskar
#GC #glasswool #MethodDevelopment #troubleshooting #PharmaGrowthHub #interview

Пікірлер: 11
@lekang8179
@lekang8179 11 ай бұрын
I ran GC many years and never thought about liners' functions, thanks for the explanations.
@sajjanrajsharma6285
@sajjanrajsharma6285 5 ай бұрын
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤
@anithaboddu6825
@anithaboddu6825 3 ай бұрын
But.. In HS, we can not use glass wool... Why??
@jaykumarbhatt8841
@jaykumarbhatt8841 Жыл бұрын
Great 👍
@tooncampingtube1330
@tooncampingtube1330 7 ай бұрын
Thank you for your sharing knowledge. Would i ask one question about the liquid sample from end of needle during injection should be evaporize above glass wool ? I fould that some spilt liner have more thick and the needle of syringe were inject insite glass wool and i fould bluffing peak. Thank you in advance.😊
@Javeedkdy
@Javeedkdy 7 ай бұрын
Thanks
@thilpanneerpanneer2327
@thilpanneerpanneer2327 9 ай бұрын
What is the position of glass will placement and suggest choosing of glass liner
@jrpmarket8538
@jrpmarket8538 Жыл бұрын
thank u sir
@akshaypimplembajourney2247
@akshaypimplembajourney2247 4 ай бұрын
How much amount of glass wool used in linear
@vijayabhaskarareddyvennapu2013
@vijayabhaskarareddyvennapu2013 7 ай бұрын
I learnt more from your vedioesand i have small doubt i.e During glycerin analysis sst solution prepared and injected and in which ethylene glycol peak is not elation which is observed after sample injections. May I know what is problem and what might be happend and why peak not eluted. Where the peak is eluted in initial set.
@pharmagrowthhub3083
@pharmagrowthhub3083 7 ай бұрын
thanks for the feedback about your learning journey. There are several reasons for carryover, and prominant one could be low flow rate, backflash in GC injector, lower column temp etc...
pH, pKa, and Retention
8:57
Pharma Growth Hub
Рет қаралды 7 М.
GC Tips and Tricks for Method Optimization
44:04
CCDG Channel
Рет қаралды 82 М.
艾莎撒娇得到王子的原谅#艾莎
00:24
在逃的公主
Рет қаралды 42 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 36 МЛН
Why acetonitrile has more elution strength than methanol in RPLC?
13:26
Pharma Growth Hub
Рет қаралды 5 М.
Basic of GC_Part 2 : All About GC Inlets
8:53
YoungIn Chromass Global
Рет қаралды 5 М.
pH Meter | working of glass electrode of pH meter
9:38
Quick Biochemistry Basics
Рет қаралды 75 М.
3 common interview questions on Forced Degradation
21:14
Pharma Growth Hub
Рет қаралды 20 М.
GC Inlet Maintenance
4:23
Nicole Karn
Рет қаралды 11 М.
Theory of Column Selection in HPLC Method Development
19:53
Pharma Growth Hub
Рет қаралды 27 М.
Gas chromatography | GC
5:25
Quick Biochemistry Basics
Рет қаралды 692 М.
艾莎撒娇得到王子的原谅#艾莎
00:24
在逃的公主
Рет қаралды 42 МЛН