How To Fix Damaged Electrical Romex Wires With 3 Methods! The 3rd Will AMAZE You! DIY Repair

  Рет қаралды 21,756

Fix This House

Fix This House

Күн бұрын

ITEMS I USED ON THIS VIDEO:
- WAGO 221 Connectors - amzn.to/3VaU3DR
- LEVITON Decora Edge 15 Amp - amzn.to/3TahrQ6
- Handybox - amzn.to/3Id4uig
- 3/8 Romex Connectors - amzn.to/3ORpAqo
- Old Work 1 Gang Electrical Box - amzn.to/3uVOUEF
- Single Gang Blank Cover - amzn.to/4bSBycU
- Combination #1 Screwdriver - amzn.to/4bP2ZV0
- Voltage Tester - amzn.to/3IcuYR3
- VOLTCLAW - amzn.to/3Idu0UI
- Cordless Screw Driver - amzn.to/3OWCJyt
- Wire Strippers - amzn.to/3OUQXQe
SHOP MY OFFICIAL FIX THIS HOUSE WEBSITE! : www.fixthishouse.net
SHOP MY ONLINE AMAZON STORE AND CHECK OUT ALL THE TOOLS I USE! www.amazon.com/shop/genevo9
☕️ Buy me a coffee 🙏🏽! This will greatly help support this channel and will allow me to help more People by creating more helpful and useful How To, DIY & Product Review videos! :
www.buymeacoffee.com/fixthish...
On this video I will be showing you How To Fix Damaged Electrical Romex Wires With 3 Methods! The 3rd Will AMAZE You! DIY Repair
Please Subscribe To Our Channel! / fixthishouse
FOR BUSINESS INQUIRES SEND TO:
FIX THIS HOUSE
P.O. BOX 2511
BREMERTON, WA 98310
UNITED STATES
FOR BUSINESS INQUIRES EMAIL ME AT:
fixthishouse1@yahoo.com
DO YOU HAVE QUESTIONS ON YOUR HOME REPAIR OR DIY PROJECT? GET TIPS, ADVICE AND ANSWERS! BECOME A FIX THIS HOUSE MEMBER!
Become a FIX THIS HOUSE Member by clicking on this link: / fixthishouse
DISCLAIMER:
This video is meant for informational, educational, and entertainment purposes only! To better your knowledge on the concepts of electricity, electrical circuitry, entertainment component circuitry and all other wiring methods. Electrical codes in my area may be different from yours so always make sure you follow and stay current with your local code. With different codes around the world constantly changing standards, regulations and rules, it is the sole responsibility of the viewer to educate themselves on their local requirements before undertaking any sort of project. That being said Fix This House cannot claim liability with all applicable laws, rules, codes and regulation for a project. DO NOT ATTEMPT ANY WIRING OF ANY KIND if you lack the knowledge and understanding required. Otherwise, personal injury and/or death as well as property damage or loss could occur. Your safety is your own responsibility, including proper use of equipment and safety gear, and determining whether you have adequate skill and experience. If you are a younger person or are inexperienced with electrical devices, ask for help from a parent, teacher or a licensed professional.
WARNING- Electricity is dangerous and can cause personal injury or DEATH as well as other property loss or damage if not used or constructed properly. If you have any doubts whatsoever about performing do-it-yourself electrical work, PLEASE do the smart thing and hire a qualified and licensed electrician to perform the work for you.NEVER WORK WITH LIVE VOLTAGE. Always disconnect the power source before working with electrical circuits.When performing electrical work, ALWAYS READ AND FOLLOW THE MANUFACTURERS INSTRUCTIONS AND SAFETY GUIDELINES. Always follow your local electrical code and requirements which are specific to local areas.By utilizing this video and the information given, YOU are expressly holding "FIX THIS HOUSE" HARMLESS FOR ANY PROPERTY DAMAGE, PERSONAL INJURY AND/OR DEATH, OR ANY OTHER LOSS OR DAMAGE THAT MAY RESULT FROM YOUR ACTIONS. Viewers must be aware by doing projects on their homes they are doing it at their own risk and Fix This House cannot be held liable if they cause any damage to their homes. Fix This House and all parties associated with it ARE NOT responsible for the use and results of this information by any party, especially those lacking sufficient skill or knowledge to perform these steps safely and ANY HAZARD CREATED IS THE SOLE RESPONSIBILITY OF THE USER.
DISCLAIMER: This video contains affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.
#electrical #outlet #diy

Пікірлер: 41
@FixThisHouse
@FixThisHouse 3 ай бұрын
ITEMS I USED ON THIS VIDEO: - WAGO 221 Connectors - amzn.to/3VaU3DR - LEVITON Decora Edge 15 Amp - amzn.to/3TahrQ6 - Handybox - amzn.to/3Id4uig - 3/8 Romex Connectors - amzn.to/3ORpAqo - Old Work 1 Gang Electrical Box - amzn.to/3uVOUEF - Single Gang Blank Cover - amzn.to/4bSBycU - Combination #1 Screwdriver - amzn.to/4bP2ZV0 - Voltage Tester - amzn.to/3IcuYR3 - VOLTCLAW - amzn.to/3Idu0UI - Cordless Screw Driver - amzn.to/3OWCJyt - Wire Strippers - amzn.to/3OUQXQe
@hebe1792
@hebe1792 3 ай бұрын
I have used the TE connector for an in-wall connection 12 years ago. No worries there, it still working well. If you think about it, it is much better than wire nuts and those are used everywhere, even in electrical panels.
@jacqjacq5920
@jacqjacq5920 3 ай бұрын
I love watching your show! I always feel smarter as a DIYer. Thanks for sharing these methods.
@FixThisHouse
@FixThisHouse 3 ай бұрын
Thank you so much friend 🙏🏽😊
@shakyzeg
@shakyzeg 3 ай бұрын
Wagon makes an"in line" connector now, 221-2401. Nice video! Thank you!
@cobuck4007
@cobuck4007 3 ай бұрын
Can these be used without a junction box?
@TomCee53
@TomCee53 3 ай бұрын
Generally no. Some area allow shrink tubing over the top.
@krg038
@krg038 3 ай бұрын
I've used them no problem. I wouldn't understand why there would be any problem when in the first place you had just the exposed cable sitting there. If you can use things in a J box why not use them on wire behind drywall. Same connection.
@shakyzeg
@shakyzeg 3 ай бұрын
I believe the latter connection shown in the video is okay. Wago in line, in the wall is a code violation. It is because it cannot handle any significant stress. There is an all metal equivalent of the same that is in wall approved. I haven't been able to find one lately. The more acceptable thing to do in drywall is add a junction box, put a blank cover on it, that is not covered by dry wall
@krg038
@krg038 3 ай бұрын
@@shakyzeg i don't follow the significant stress. I tried to pull apart an inline Wago. Its hard. Wago tests show current in a Wago connection exceeds the wire capacity. My bet is the code isn't up to date enough for Wago connections. It can't be for protection since you can drill into the romex wire in the wall as easily as a Wago connector.
@ErichMoraga
@ErichMoraga 3 ай бұрын
Converting a bad section of cable into a working outlet is like making lemonade from lemons. I like it👍
@rshoe1023
@rshoe1023 3 ай бұрын
By adding in a receptacle is a great idea, but on the same note it's not code compliant now. Wires are to short now extending from the box. I forgot what NEC code # this is off the top of my head. But I know tit's not code compliant.
@blackhorse2947
@blackhorse2947 3 ай бұрын
Always very good video ………for DYI’r
@FixThisHouse
@FixThisHouse 3 ай бұрын
Thank you so much my friend! 👍🏽😊🙏🏽
@willmallory9085
@willmallory9085 3 ай бұрын
I love this channel.
@FixThisHouse
@FixThisHouse 3 ай бұрын
Thank you so much my friend! 👍🏽😊🙏🏽
@RapidRepair
@RapidRepair 3 ай бұрын
Those in line connectors are fine...they have been used in the manufactured / modular home building industry for decades now...🛠🛠
@edsyphan3425
@edsyphan3425 3 ай бұрын
Ive never seen these before, kind of remind me of those junk 3M Scotch Loks.
@cardonn364
@cardonn364 2 ай бұрын
Would you recommend using those connectors to splice 8 gauge electrical stove wires. Please let me know
@howtodoitdude1662
@howtodoitdude1662 3 ай бұрын
All splices should be accessible. They do have heat shrink connectors for 12 gauge wire.
@FixThisHouse
@FixThisHouse 3 ай бұрын
Thank you for the info my friend 🙏🏽😊
@ronm6585
@ronm6585 3 ай бұрын
Thank you. Not sure about the 3rd option though.
@FixThisHouse
@FixThisHouse 3 ай бұрын
Thank you brotha 🙏🏽😊👍🏽
@smacfe
@smacfe 3 ай бұрын
Very nice. But I wish you would have shown how to deal with a damaged wire with no slack at all.
@FixThisHouse
@FixThisHouse 3 ай бұрын
No worries! For no slack just easily use pigtails 👍🏽😊
@mattalbrecht7471
@mattalbrecht7471 3 ай бұрын
Did i not see the link for the TE connector in the description?
@wesdog8975
@wesdog8975 3 ай бұрын
So, using wire nuts to splice the wires together is not recommended?
@glengivens2725
@glengivens2725 2 ай бұрын
Mount the box facing outward and past the edge of the framing about 1/2". When someone installs drywall the box will not be covered. Seen inspectors fail the side mounted boxes for this very reason.
@TomCee53
@TomCee53 3 ай бұрын
I’m not seeing a link from the TE connector. Where can I get them?
@aaronblackford981
@aaronblackford981 3 ай бұрын
Ty for teaching new NEC regs. But it still kinda sounds like it has To inside if a junction box imo. Idk. The leglaleese crap drives me insane. But your way would prob be in an none accessible box and legal I would think. Maybe. Lol
@elreydelmundo8499
@elreydelmundo8499 3 ай бұрын
can you just tape it?
@rshoe1023
@rshoe1023 3 ай бұрын
AH no!
@sitthisayphomsouvanh5249
@sitthisayphomsouvanh5249 3 ай бұрын
The third method is piece of grab , I have seen it burnt inside the wall , that is fire hazard, this method should not be allowed to bury inside the wall. The junction box with wire nuts if you make sure it is tight it is even better than this method, but funny code not allow junction box with tight connections inside the wall but code allow this piece of grab to be concealed in the wall. Electrician is my trade and I have been doing this work over 35 years, I have seen all kind of loose connections that lead to fire. Definitely the third method should not be allowed
@jaywhite1850
@jaywhite1850 3 ай бұрын
Not sure how useful any of this is considering there’s usually not enough slack in lines.
@Slimhaven1
@Slimhaven1 3 ай бұрын
TE looks like pure fire hazard!!!
@trukin74
@trukin74 3 ай бұрын
What is wrong with you? You should ALWAYS connect the ground followed by the neutral and the hot wire LAST.
@johnreichow907
@johnreichow907 3 ай бұрын
What difference does it make, as long as the power is off ??
@trukin74
@trukin74 3 ай бұрын
@@johnreichow907 It has to do with safety. Just because you shut off the power, that doesn't mean someone else can't turn it back on while you are working on that ciruit.
@thenathanielhardyproject8675
@thenathanielhardyproject8675 3 ай бұрын
👍🏿 agrees with @trukin74 I have seen this happen where someone was shocked 😳 because someone turned the power on at a job site.
@kimchee94112
@kimchee94112 3 ай бұрын
@@trukin74 Should tag the CB as not to turn on.
I Built a Shelter House For myself and Сat🐱📦🏠
00:35
TooTool
Рет қаралды 30 МЛН
Шокирующая Речь Выпускника 😳📽️@CarrolltonTexas
00:43
Глеб Рандалайнен
Рет қаралды 11 МЛН
100😭🎉 #thankyou
00:28
はじめしゃちょー(hajime)
Рет қаралды 58 МЛН
How To Fix Sunken Outlet | 2 Easy Options
10:17
Everyday Home Repairs
Рет қаралды 2 МЛН
How to Extend Short Wires | Easy Fix Anyone Can Do
6:52
The DIY Guy
Рет қаралды 2,9 МЛН
How To Add An Outlet To A Finished Wall
10:51
Everyday Home Repairs
Рет қаралды 10 МЛН
5 CLEVER Electrical Tricks Everyone Should Know
11:06
LRN2DIY
Рет қаралды 3,4 МЛН
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,2 МЛН
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Artisan Electrics
Рет қаралды 471 М.
2 Most Common Issues DIYers Make With Metal Electrical Boxes
10:33
Everyday Home Repairs
Рет қаралды 1,6 МЛН
How To Repair Damaged Romex Wires
9:47
Everyday Home Repairs
Рет қаралды 952 М.
Самый безопасный мотоцикл в мире 🏍️
0:37
ОМЕГА шортс
Рет қаралды 2 МЛН
ГИБКОСТЬ 80 LVL
0:18
В ТРЕНДЕ
Рет қаралды 2,4 МЛН
ToRung short film: 🎂the cake is delicious🎂🤤
0:37
ToRung
Рет қаралды 7 МЛН
Which one is the best? #katebrush #shorts
0:12
Kate Brush
Рет қаралды 19 МЛН
She ruined my dominos! 😭 Cool train tool helps me #gadget
0:40
Go Gizmo!
Рет қаралды 17 МЛН