How to | install | 200 amp | Underground | Electrical service

  Рет қаралды 10,945

ElectricianJoe

ElectricianJoe

Күн бұрын

Пікірлер: 19
@JM-iz3fr
@JM-iz3fr 2 ай бұрын
Its always great to see how someone else does there work, we all learn from others weather we feel what they do is right/wrong. Great tutorial- no one is without fault, dont listen to the naysayers!
@kev1nacho
@kev1nacho 9 ай бұрын
Great vid Joe! Never really believed in service loops either. Glad to see you agree!
@electricianjoe
@electricianjoe 9 ай бұрын
🫡
@quadcityracing
@quadcityracing Ай бұрын
Is that a 200 amp disconnect after the meter socket and does it count for the new exterior emergency shutoff code?
@SolarGuyInMaine
@SolarGuyInMaine 9 ай бұрын
The “leave you mess” part killed me! 😂 Do you ever install azek for mounting enclosures on the exterior? Also, service loops are use now becoming helpful for solar. We do a lot of taps, and the extra slack is nice to have.
@Eightball2516
@Eightball2516 9 ай бұрын
You did not use any nolox on those aluminum conductors
@token2474
@token2474 9 ай бұрын
I was just gonna say thst then seen this
@electricianjoe
@electricianjoe 9 ай бұрын
Correct. Aluminum alloy lugs. Aluminum wire. No need
@vince6829
@vince6829 9 ай бұрын
Thanks for sharing your knowledge.
@gavynpurdy3102
@gavynpurdy3102 9 ай бұрын
How do you ground your electrical system with no ufer or rod electrode in the meter/main?
@tbonemckone
@tbonemckone 5 ай бұрын
Circ saw works on aluminum conductor too. Inspector showed me that trick.
@Rysdad1
@Rysdad1 Ай бұрын
Can you leave the old 100amp panel inside that the house already has and install this outside with the 200amp panel and it still meet code for the "outdoor cutoff" requirement and this count as a 200amp service upgrade so the power company will hook you up? And if you do leave the old 100amp panel inside to basically make it a sub panel does that mean you dont need to change the line from the old 100amp panel to the new 200amp meter/panel/cut off thats outside? If so that will completely change what im doing
@electricianjoe
@electricianjoe Ай бұрын
Yes you can do that. Just make sure you install a 100amp breaker in the outside panel to feed the sub panel. Also make sure you have proper grounding.
@TheDrick28
@TheDrick28 Ай бұрын
Can you have a electric man install a 200 amp panel with breakers outdoors and grounded, and the homeowner install a subpanel later inside?
@JM-iz3fr
@JM-iz3fr 2 ай бұрын
Did I miss you using antioxidant??
@stevencoons450
@stevencoons450 3 ай бұрын
I have a few questions. 1. Did you seal the hole into the house? 2. Why didn't you put a backer board?
@norcoauctions
@norcoauctions 5 ай бұрын
typical electrician, using wire cutters as a hammer
@MundiTaurus
@MundiTaurus 4 ай бұрын
So, you're learning to be an electrician.
@tvguypro3873
@tvguypro3873 27 күн бұрын
This is probably NOT how to do video.
200 Amp Electrical Service...EASY TO FOLLOW INSTALLATION
19:06
Spicer Designs
Рет қаралды 38 М.
DIY Pulling Buriable Electrical through PVC
5:29
RMSpeltz Farm - ReefDVMs
Рет қаралды 1,1 МЛН
Война Семей - ВСЕ СЕРИИ, 1 сезон (серии 1-20)
7:40:31
Семейные Сериалы
Рет қаралды 1,6 МЛН
번쩍번쩍 거리는 입
0:32
승비니 Seungbini
Рет қаралды 182 МЛН
Overhead & Underground Electrical Utility Service
15:52
Electric Pro Academy
Рет қаралды 65 М.
Installing 100 AMP SUB PANEL -  THE COMPLETE PROCESS - SAVED THOUSANDS $$$
25:22
Underground Electric Service Start to Finish
22:06
Tony's Tractor Adventure Homestead
Рет қаралды 21 М.
How to Install 220v outlet in Garage the Easy Way = Run from Basement
8:20
200 Amp Meter/Breaker combination box for New cabin.
7:31
Country View Acres (Formerly Smalltown442)
Рет қаралды 188 М.
How to Replace an Electrical Service Panel, Meter, and Riser (PART 1)
12:21
Grounding and Bonding an Electrical Panel
13:24
Appalachian DIY
Рет қаралды 344 М.
How To Install a Sub Panel Start to Finish!
31:44
Benjamin Sahlstrom
Рет қаралды 2,4 МЛН
How and Where to Install Ground Bars on Panels
4:43
Sparky Channel
Рет қаралды 136 М.