How to Install a Square D SPD Surge Protection Device

  Рет қаралды 29,532

Land to House

Land to House

Күн бұрын

To protect your home from electrical surges the Square D whole home surge protector is the device you need. It is easy to install and has an LED to show it is working properly.
From the Manufacturer:
The HEPD50 is easily connected to any brand of residential load center and provides the customer a green status LED to ensure proper protection
Includes an LED indicator
NEMA 4X rated for outdoor/indoor use, 50,000 amp Surge Current Rating, 25,000 amp SCCR. CSA and UL 1449 3rd Edition Type 1 SPD
Find the Black color version of the Square D SPD on Amazon:
amzn.to/3Whm2OX
Ram Pumps available on AMAZON
amzn.to/2EWrQHN
Also available on Land To House Website:
www.landtohouse.com/rampumpsales
Help Support land To House by Paypal:
paypal.me/landtohouse
Send Mail to Land To House:
Land To House llc
P.O. Box 323
Micaville, NC 28755
See whats coming up before it hits KZbin on my Facebook Page:
/ landtohouse
Land To House is a participant in the Amazon Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com

Пікірлер: 32
@douglas_drew
@douglas_drew Жыл бұрын
Had a dryer fire a few years ago that could have been a full house fire had it not been for the quick action of my nephew (I was away at work) and the ready placement of a proper fire extinguisher (our local volunteer fire department being five miles away made it for the cleanup, bless them all). Everything that was on at the moment got zapped (TVs, Oven, a couple of game systems), and the company that installed a new service from our pole said it was undoubtedly a surge, but from unknown sources. Our HomeOwners insurance (the people with the mighty Stag...) wouldn't pay a thing since we couldn't prove where the surge came from (of course, we changed insurance companies after that). Surge protection is well worth the costs!
@cedantioch
@cedantioch Жыл бұрын
I'm sure someone pointed it out earlier, but what you installed was the HEPD80 vs the HEPD50 as mentioned in the content above. Same installation techniques of course. Good work. - CED Antioch
@viraj.khanna
@viraj.khanna Жыл бұрын
Awesome video dude!! Thanks so much for the tips!!
@LandtoHouse
@LandtoHouse Жыл бұрын
Happy to help! This was installed because a nice power system is going in here at the house. Full install video coming soon!
@wazzouz
@wazzouz 7 ай бұрын
Very helpful. Thank you. Much appreciated.
@workbenchz
@workbenchz Жыл бұрын
Well done on the install. I looked up the specs on Square D surge protection and it's quite impressive.
@sparx1951
@sparx1951 14 күн бұрын
Working in a panel box wearing a wristwatch. I could tell you horror stories about doing that!
@Sylvan_dB
@Sylvan_dB Жыл бұрын
Due to the physics of surge protection, it would be better to connect the ground as close to the grounding electrode conductor as possible (I'd put it in the next hole even if I had to move a wire out of it) and the wires should be trimmed to a minimal working length. But any install is better than nothing for surge protection!
@Jaw-t3t
@Jaw-t3t Жыл бұрын
Thanks for the comment. I'm just about to install one of these so I came to KZbin for more info. My grounds and neutrals all mixed up on the bars as they are bonded anyway. I was still going to treat them as they are separate. Attach the ground close to the main ground, and neutral near the neutral coming from the service. Does that make sense?
@Sylvan_dB
@Sylvan_dB Жыл бұрын
@@Jaw-t3t Sounds like a good idea to me. Be careful!
@diydarkmatter
@diydarkmatter Жыл бұрын
thats a nice hornets nest you got there . lol . happy new year buddy .
@LandtoHouse
@LandtoHouse Жыл бұрын
This past year was one of the busiest hornets years I've ever seen. Must have taken care of 6 of them. Happy New Year. Thank you for being part of the channel 4 such a long time.
@diydarkmatter
@diydarkmatter Жыл бұрын
@@LandtoHouse its been fun buddy thank you for your content .
@jayescreations489
@jayescreations489 Жыл бұрын
I wanted to install this. however I dont have any blank spots for additional breaker.
@Matt-un8gi
@Matt-un8gi Ай бұрын
So basically the surge protector doesn't get installed in a series but is more of a passive device meaning it only has to be on a live circuit anywhere connected to the panel
@MercedesMechanic
@MercedesMechanic Жыл бұрын
Is it your understanding that I must add a new breaker in an empty slot to my panel to use this? They say to hook it to a 15, 20 or 30 amp two pole breaker but they don't specify whether or not you're supposed to add a breaker just for it. Also, I'm wondering which size of these 3 breaker choices is the best or does it matter as long as its a 15, 20 or 30?
@LandtoHouse
@LandtoHouse Жыл бұрын
The product recommends that you install this as close to the top of the box as you can. Dedicated breaker is recommended. The wires on this unit are a small gauge so any of those mentioned breaker amperage should be just fine.
@TheDaddygeek
@TheDaddygeek 11 ай бұрын
My circuirt panel is inside the house and embedded in a plasterboard wall. What is the best way to mount a whole house surge protector?
@asusreviews
@asusreviews 2 ай бұрын
Just get a smaller kVA breaker style unit. It's plug and play.
@BrittCHelmsSr
@BrittCHelmsSr Жыл бұрын
How about that hornets nest under the breaker panel?!? Nice tutorial on how to install this surge protector.
@LandtoHouse
@LandtoHouse Жыл бұрын
Say hello to my little friends. They "moved on" about 2 years ago.
@BrittCHelmsSr
@BrittCHelmsSr Жыл бұрын
@@LandtoHouse Their nest would serve as a good deterant to anyone who didn't know that they were gone.
@VenomInMahEyes
@VenomInMahEyes Жыл бұрын
How does this surge protector work exactly?
@workbenchz
@workbenchz Жыл бұрын
If the voltage spikes above 600V between one leg and neutral, or above 1000v between the 2 legs (black wires), the Metal Oxide Varistor inside it shorts the extra voltage through itself to try to keep the house voltage from spiking up. Most spikes last a tiny fraction of a second so it can handle quite a large jolt, as much as probably 80,000 amps through itself for that tiny fraction of a second.
@rickjames6948
@rickjames6948 Жыл бұрын
Um, not how I would mount it. Wires as SHORT AS POSSIBLE. As CLOSE to the neutral/ground buss as possible. Why? For every inch of wire length, you increase the clamping voltage by 20-25 VAC. So if that device dumps voltage/current at 600VAC, you add on say another couple hundred volts for example till it starts working. Shot wires short wires.......
@byronholt4912
@byronholt4912 3 ай бұрын
Says so right in the instructions, Page 4, very first paragraph.
@LightitupLEDs
@LightitupLEDs 6 ай бұрын
Looks a little crooked might want to turn it to the right a few degrees.
@llldaslll1590
@llldaslll1590 3 ай бұрын
LOL, I thought the same thing, must be my OCD!
@nic6754
@nic6754 Жыл бұрын
"In my box" 😆 sry everyone 😞 ❤️
@nickvasquez3173
@nickvasquez3173 4 ай бұрын
14g wire on a 20a? Lol
@JohnnyUtah9173
@JohnnyUtah9173 Ай бұрын
I caught that too 🔥
@rumsiker
@rumsiker 4 ай бұрын
this guy need to learn how its installed , i think he never read the instructions
How To Install A Surge Protector
11:14
Electrician U
Рет қаралды 165 М.
How Many Balloons Does It Take To Fly?
00:18
MrBeast
Рет қаралды 179 МЛН
Little girl's dream of a giant teddy bear is about to come true #shorts
00:32
Whole House Power Backup Solution | Generator Inlet Box Install
12:22
Everyday Home Repairs
Рет қаралды 739 М.
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,2 МЛН
Easiest Way to Start a RAM PUMP
8:50
Land to House
Рет қаралды 4,2 М.
AFCI vs GFCI: What's The Difference and Why You Should Care
10:43
Top Homeowner
Рет қаралды 1,3 МЛН
Shed Electrical Installation (How to Add Electricity to a Shed - DIY)
12:16
Andrew Thron Improvements
Рет қаралды 669 М.
How To Install a Whole House Surge Protector in your Main Panel
8:54
Benjamin Sahlstrom
Рет қаралды 125 М.
How Many Balloons Does It Take To Fly?
00:18
MrBeast
Рет қаралды 179 МЛН