Hi I am trying to understand why mosfet damaged in a inverter dc to ac circuit a simple circuit showing 2npn mosfet connected to a half bridge inverter with only Shockley diodes to drain and source and diner diodes to gate and source but the mosfet switching convert dc to ac for only 1 minutes and mosfet failed this action happened with all 20 mosfet tested the mosfet is switching hard start but igbt turn on the transformer easy and smoothly converting and work perfectly for hours and still work but when replaced with mosfet irfz44n and irf 3710 the mosfet all fail even with a sic circuit inplace so con you explain to me why this is happening with the mosfet with no low but igbt work but mosfet fail
@ilyasboujraf605110 ай бұрын
hello brother i hope you are fine please i would like you to help me in this topic SiC power devices characterization and modeling for embedded power converters
@lo27409 ай бұрын
This is an OnSemi presentation, is not the place to seek help for your specific repair issue.
@Dc_tech3869 ай бұрын
@@lo2740 it’s ok I get pass that along time ago and my answer to why and fix it everything is ok
@thomasmaughan47988 ай бұрын
MOSFET has rather high capacitance and a sharp transient especially turn-off will pulse the gate. This can make turn-off fail and in a totem-pole arrangement, the top and bottom MOSFET can turn on simultaneously which is a short circuit from battery. Also, MOSFET has very low "on" resistance which can allow high current flow if feeding a capacitor (for instance). Abrupt turn-off can produce high voltage if feeding into inductance even if you have a snubber diode if the diode is not fast enough (or able to handle high impulse current).