PARTS LIST: 12/3 SJO Bulk Wire amzn.to/30wrS2l Hubble Edison Male Connector amzn.to/2lltAEA Leviton 15amp Outlets amzn.to/2llyiCh Handy Box amzn.to/2XYjaMV Handy Box Cover amzn.to/2lk3h1x Metal box Cable Connector amzn.to/2llGcvr Electrical Kit amzn.to/2lkKWl0 Velcro Ties amzn.to/2llEeew
@air_rue235 жыл бұрын
John Simmons this is A Great Video! Thx u
@duanecurry46764 ай бұрын
Excellent video! I'm an electrician, and everything was up to code. Plus you explained each step in an easy, and accurate manner. Keep up the good (safe) work!
@mikey386322 ай бұрын
12:20 also consider cable lube, especially if you are making several of these, or you need them to be water resistant/weatherproof
@BSP18224 жыл бұрын
I just watched a video of you teaching me how to do stuff I know how to do already. Still watched the whole thing haha. I love your videos. keep em coming!
@pyro04833 жыл бұрын
lol same here!!
@kylesims98065 жыл бұрын
I too am not a certified electrician but I would like to put out there that is box should only be used indoors never for out doors because that box would shock you if it gets wet. For outdoors you need a sealed box with rubber gaskets or use gfi plugs
@Endmass5 жыл бұрын
Hmmm. Only one plug needs to be GFCI, and you'd want it downstream on the stinger if putting in more than one box. Correct?
@kylesims98065 жыл бұрын
Like I said before I am not a electrician but I do know about electric. I have worked with touring companies we had two versions of stringers when ones with no gfci but in a sealed box because if you need power up high you don’t want to mess with gfci in a box 20’ 30’ feet up on the air. Then we also provided power off the generator for vendors and those are gfci.
@EscapeEFT4 жыл бұрын
You can use a box called a "wet conditions junction box" to make this with a plastic cover that has flaps to cover the outlets.
@MattyBeeProductions Жыл бұрын
@@Endmass yes correct, if you're plugging this box into a circuit that already has GFCI then you're good to go
@DaveSmithmoneymagnet2 жыл бұрын
This is one of the best tutorials I have seen on how to do this!
@Meeper762535 жыл бұрын
Great video! I build all of my own power cables as well. But, as an industrial Electrican as my full time job, I'd like to offer my opinion. Those receptacles are 15a. I would recommend a commercial grade receptacle. A good brand would be a Pass and Seymour CR5362. It's a heavy duty 20 amp load rated receptacle. Another tip would be on the box itself. Like the other commenter said, this is for INDOOR use only. Also I would use a ground screw/wire and ground the box as well. If you wanted one for outdoor use, you should use 1 GFCI receptacle and load the CR5362 beside it. Install them in what is called a 2 gang Bell Box. And a weather rated flip cover. Also use a weather rated, S.O. cord grip box connector. Hope this helps someone. Good video, and great idea to make them yourself!
@DjWooPig5 жыл бұрын
Since your are actually an electrician (or at least claim to be), you can probably help answer my question. Would the center screw used to attach the cover to the receptacle to the cover not ground the box? The center screw ties directly to the ground bar in the receptacle itself correct?
@Meeper762535 жыл бұрын
@@DjWooPig Okay, first of all I'm going to forget that you are calling me a liar about being an electrician. Because I really like you and your videos. I think you're a good person and a good business man. Anyway, the center screw, especially on a 15 amp receptacle is basically just for holding on the plastic coverplate, like in your house. The 2 tabs on the top and bottom of the receptacle that you cut off are for holding it to the double duplex RS cover . The little tabs that you bend away have a threaded hole, you take the 6-32 screw that came on the receptacle and screw it through the front of the cover, through the hole in the receptacle, the one you cut in half, and thread it through that little metal tab from the cover. This give the receptacle some rigidity for plugging in and out over time. That center screw won't hold up in time. Eventually you will go to plug something in and it will strip out and the receptacle will fall into the box. Second of all, to get technical, the center screw is a size 6-32. Yes, it will still read out on a meter or plug tester that it is grounded. But according to the NEC, the national electrical code, a 6-32 is not rated for a 20amp ground fault current. However a 10-32 size screw, or a ground screw is. For example, if one of the hot wires from your receptacle comes off the screen and touches the box, that fault current will blow apart or melt that 6-32 screw before the breaker even trips. A 10-32 screw with 3 threads of contact, is physically large enough to withstand that fault current and will trip the breaker. I'm not trying to be a prick, I'm just trying to help. I'm sorry if I came across as a know it all.
@DjWooPig5 жыл бұрын
Nate Flanigan I never called you a liar. People say they are lots of things on the internet but don’t have any merit to back it up. I was genuinely curious because I have been told that the center screw is a grounding source. I even took one of my outlets I used in the video and found it was attached to the ground bar. I’m not saying I know everything, or that I’m an electrician, just curious as to why the ground screw in the middle can’t be considered a ground when metering it out. The screws on the box cover seem like they are bigger that the ones I I didn’t use. I could be wrong on that one though. It’s all good, you gave me the answer I was asking for.
@Meeper762535 жыл бұрын
@@DjWooPig you're right, the screws holding the cover on are bigger. They're 8-32. And ya I understand about the internet thing. I was just offering my opinion and knowledge. Not trying to tell anyone that they're wrong, or insulting them. Just telling what I do on a daily basis.
@DjWooPig5 жыл бұрын
Nate Flanigan cool. shoot me an email, We May have to collaborate on some entertainment and electricity related.
@blazinSpike11 ай бұрын
I used to build power boxes for my high school music DJing equipment when on the road. I could get them done on the fly when needed more power options
@coachpeterL5 жыл бұрын
Wondering why you did not ground the metal box? I don't think I'd use these out on a job since I'm not an electrician and the liability would be great if something happened...though I have made them before for home use.
@jessecoonen78813 жыл бұрын
The box is grounded by the center screw/bolt from the outlet
@billocampo13654 жыл бұрын
I build a bunch of them, but I made the power box with shorter cables, so I can just connect it to my 100, 50, 25, 10 ft, extensions, most of them are built into a closed box
@mikejackson72434 жыл бұрын
Great video. One thing I do in addition to what you show is I spray my boxes with Plasti Dip paint. The rubberized coating stands up to lots of abuse and when done in black, hides them on stage a little better.
@embarkavl3 жыл бұрын
Everything is right except for one important thing: you NEED to ground the grounding conductor to the metal box. Get some grounding screws and it screws into the bottom of a metal box.
@dantonliam5 жыл бұрын
I have 2 I built in the winter....love them!
@mykonyte5 жыл бұрын
Love the video, I’m all about repurposing materials my 9 - 5 job is commercial Hvac so I know a little about electricity so I reuse left over materials from jobs. The only minor thing I can say, on your crispers you will notice engraved non and insulated that’s for the prongs you used with the plastic jacket is considered insulated and it makes a better crimp on them. Not that you can’t do it they way you did, I have broken many connectors doing that way. Love the videos, always informative you’re the man
@jakes.55913 жыл бұрын
Just fyi this is half wrong. Look up SO cord connectors. Also look up OSHA rules for metal power distribution boxes.
@mikey386322 ай бұрын
I think that after looking for smoke, and listening for buzz, I'd look at the lamp or listen for the radio I plugged in before hooking the plug to power and switching the power on! Too soon for touching till the lamp works and the tester says wiring is correct!
@kennyray116C5 жыл бұрын
So, this past Saturday, i had a wedding gig that i had to m.c. There was no planner so all the logistics were handled by me and the groom basically. Your video on how to prep yourself to relax and handle the job really helped me. everything from chewing gum to not rehearsing to much helped me more than you know. Thank You.
@drummerdude83235 жыл бұрын
How is this different/better than just running a heavy duty extension cord with a surge protector on the end??
@LioHmusic5 жыл бұрын
x2
@adamsblanchard8362 жыл бұрын
Support this guy he goes out his way
@divinesoundandlighit2 жыл бұрын
made mines after seeing this video 1.5 years ago!!!! had to go BACK to it for reference...lmao Good shit!!!
@yourfirekiller5 жыл бұрын
Great! John, how do you handle venues that do not have a commercial power service for your distro? Do you source multiple circuits via extensions cords?
@jefftown6042 жыл бұрын
Yes u do
@playmedialive94254 жыл бұрын
Love the channel bro. But for this project I suggest putting both hot side together in the middle of the box, if the punch hole disks on the sides get pushed in by chance it can’t rest on the hot wire and make the metal box live. Also I would ground the box too as another safety measure.
@DouglasMarsh9s5 жыл бұрын
Am I the ONLY one that was distracted by the kitten!? Think John needs a new mascot!! (or at least hold the cat up to the camera)! Can also look at something like L14-20P (single phase common neutral 120/240V 20A Plug) to two (dual) 120V NEMA 5-20R (or -15R for 15 Amp only) outlets and make use of that cut/unused red wire. Most venues with 120/240V outlets/drops probably have wiring and electricians as apart of the rental contract. So the single 120V NEMA 5-15R/20R plug to a quad as in this video is the most likely scenario you will encounter. [[ The way I remember the part number L for Locking, 1 for single phase, 4 prong = L14 ]] P.S.> good practice to bond the incoming ground to the box/case first, THEN two pigtails grounds from same ground spot on box to the receptacles grounding lugs.
@DouglasMarsh9s5 жыл бұрын
@StringerNews1 Yeah I wasn't discussing 3-phase, but it is always good to understand connecting across phases yields different voltages (208v) from typical single phase. In a corporate/business with 3-phase and 208v at some up stream panel, the electrical engineer on site (and usually available as apart of the contract) would handle the 120V drops (via a transformer downstream 208v->120v) and again back to the most common scenario and purpose for the video. Side comment , I am glad to see somebody else describing/using "split phase" (120/240V using a center tapped transformer a pole upstream) which is just part of the upstream single phase from the pole instead dual to two phases (they are really more similar to polarity changes than a phase change).
@7xchad3 жыл бұрын
These 4 gang stingers are great! You can also put a 2 gang in the middle and end of a cable and have a common circuit for stage left/stage right power.
@lancethrustworthy4 жыл бұрын
I had never heard the term 'stinger' refer to a power box before. Thanks for enlightening us.
@petershute35804 жыл бұрын
Have a look at wiring diagram for 240v
@krusher5 жыл бұрын
Your forgetting to wrap the outlets with electrical tape to ensure no inside connection with anything bad. Safety first and it’s a cheap helper. Only for indoor use also. That’s an open box.
@jackiepoole58225 жыл бұрын
Great job. Been working out and it shows looking good
@geraldkoziol20722 жыл бұрын
NEC 250 4a Metal boxes shall be grounded and bonded.
@djsuccess48112 жыл бұрын
Thanks a lot. Very well explained and I will be trying this out.
@mrhillcityva4345 жыл бұрын
Excellent video dude...I'm going to make me 4 of these tomorrow.
@mtldjtechnical4 жыл бұрын
I am DJ and Electrician. The box you made is not grounded. It's important to ground the box in case a live wire inside becomes loose and touches the box. With the box grounded that would cause a short circuit and the breaker to jump. In your case not having grounded the box the circuit would remain active and if you or a client touch the box you can get an electrical shock or worse get electrocuted.
@djdericb6065 жыл бұрын
Looking good bro I see you getting fit 😎💪🏾
@rickjames3024 жыл бұрын
Lube wire where it stabs through edison connector clamp housing half prior to splitting and stripping cable. This prevents you from fighting and having to cut the weather gland. 2. Invest in flush cut pliers. 3. Thank you for having proper crimping pliers. 4. Always run a ground wire to your metallic box (regardless that it is “grounded via the center screw on outlet to cover.” If that was a non metallic box that would be a different story. 5. The parts you cut off each end of the outlet has a screw hole for further attachment to lid.
@DaleChristenson3 жыл бұрын
I would also add that the crimper has two dies on the jaws. One is for insulated connectors, the other is for uninsulated connectors. He used the wrong die. Those “notches” in the connector will cause the insulator to pull off the metal connector over time.
@djchamac02 жыл бұрын
Hey man. So there's no need to ground it to the box itself? And have you had any problems with them at all?
@southern66ss5 жыл бұрын
Been waiting for this!!!
@air_rue235 жыл бұрын
I work at a place that got all electric and plumbing stuff
@fredthompson25015 жыл бұрын
You need to ground the box. Our use plugs with grounding straps built-in
@jessecoonen78813 жыл бұрын
The outlets are grounding the box with it’s center bolt/screw.
@EDLEXUS5 жыл бұрын
Here in germany nobody builds zhem because it is cheaper to buy them than to have the time to build them. Also it is not so legal to use them if you are not an electrician
@cameronlockett56985 жыл бұрын
Thanks for the power tip
@silverfoxxsound67684 жыл бұрын
Hay I know this is an old video but did you see the mouse that made it way by
@DjWooPig4 жыл бұрын
Lol that’s my mouse catcher shop cat
@januarymorris90875 жыл бұрын
Greatly appreciate the info!!!
@vasanthkumar-tv3xx4 жыл бұрын
Thanks for advice I am watching from India(andhra pradesh)
@wbuttry15 жыл бұрын
good video needed to learn how to make those cables thank you bro
@jahholmes4 жыл бұрын
Should you ground the box🤔
@jessecoonen78813 жыл бұрын
The box is grounded by the center screw/bolt from the outlet in this instance
@DjDre-615 жыл бұрын
Thank you so much, for this video. I am going out and make me some cable.
@djtrepound24075 жыл бұрын
do you make your own iec-xlr combo cables?
@shansyiem48625 жыл бұрын
I like your systems man👍👍👍
@djrickyredz5 жыл бұрын
Can these be made with powercon connectors? Never seen any in the wild.
@deejayduy5 жыл бұрын
yes you can, i've done them in all powercon for some of the stinger
@HamAviationFilms2 жыл бұрын
The cat 😍
@diplomatfromspace4 жыл бұрын
Is THE Cats Name: Edison Also???? AND Why does this Cat show up @ 4:20 ..... he's actually a Roadie?!
@DjWooPig4 жыл бұрын
Hahaha he name is actually LEKO!
@10110100214 жыл бұрын
!! Please GROUND the box !!! Love your videos but that won't fly if inspected. Yes...it's contact grounded with the plate screws but not %100 safe and not correct. After a few years of use if that hot wire gets loose...and a plate screw is loose that box can be energized! Best to everyone! Love your positive videos.
@jessecoonen78813 жыл бұрын
The box is grounded by the center screw/bolt from the outlet
@LaurieHolbrook5 жыл бұрын
Need to ground the box. Especially since the cable clamp is metal. Those are dangerous. Love your stuff though.
@jessecoonen78813 жыл бұрын
The box is grounded by the center screw/bolt from the outlet
@tinyb693 жыл бұрын
In all honesty, and I do mean this in the most respectful way, the title should be changed to "How NOT to build your own stingers."
@andrewward73183 жыл бұрын
Bruh I’m not gonna lie I thought that cat was a RAT 😂
@jacoporiccilaltro Жыл бұрын
Electrical in US is so sketchy damn
@shansyiem48625 жыл бұрын
I want to be your friend what shall I do
@diebeatz5 жыл бұрын
Great idea but be careful using this boxes on union gigs .
@chrismoe12075 жыл бұрын
This is nifty, but I’ll spend the extra on a power conditioner.
@ludman22995 жыл бұрын
Stringers and conditioners are both essential.
@Aaronproductions5 жыл бұрын
You didn’t ground the box though....
@DouglasMarsh9s5 жыл бұрын
I commented on that as well but before reading your comment. Yes, the focus on recent NEC changes puts more focus on proper grounding order. Ground the box first so if all else fails, there is a safety path back to ground. If the box is floating and a hot wire come in contact with the metal box, it is NOW dangerous to touch. This happened at 2018 NWPAS (North West Pinball and Arcade Show) where two machines side by side had live mains between the cases. One thing the electricians did THIS 2019 year was test all equipment against earth ground early on. I have two posted videos (on in 360 VR) of the venue before opened to public!
@jessecoonen78813 жыл бұрын
The box is grounded by the center screw/bolt from the outlet in this instance
@dallasthies33442 жыл бұрын
BTW, if you use isolated ground outlets you will not have ground loops in your system when you put the "handi-box" on the ground or on concrete floors.
@arcakhangaming Жыл бұрын
Fantastic! Thank you so much brother!
@krbourgeois5 жыл бұрын
Boxes with knockouts are illegal for portable cables. USE PROFESSIONAL EQUIPMENT
@speedlimit68695 жыл бұрын
Sooo.... the cops are coming? Right? Stop being judgmental, define professional equipment, if I make it or a store makes it , it still was made. By the way my cords are bought construction grade. But that doesn’t make them pro .
@speedlimit68695 жыл бұрын
Max G umm construction grade store bought mr maxi G... I didn’t make it I paid for it. Stop trying to degrade me when I never said nothing to you. The only professional equipment you probably handled are Dez. I respect a guy who is trying and they have to go that route and make what they need to get the job done. It’s clear you don’t know what it is to make thing and do it right because you don’t have creativity. If it’s done right there isn’t anything wrong.
@donaldspaulding69735 жыл бұрын
Also, SJO isn't legal either. I believe the "J" means entertainment purposes only, not professional. If an insurance company ever got involved, only SO, SOO or SOOW is covered.