How To MAXIMISE Your Heating Efficiency In 3 Simple Steps | Boilers & Heatpumps | Consumer Advice

  Рет қаралды 96,220

Heat Geek

Heat Geek

Күн бұрын

Пікірлер: 330
@HeatGeek
@HeatGeek 2 жыл бұрын
Join 'Heat Geeks Heating Help for Homeowners" on Facebook for bespoke advice on YOUR specific system.
@IanMcLean-h2g
@IanMcLean-h2g Жыл бұрын
I am looking at heat pumps but i live in a BISF house that has been externally insulated early 2005 the question is it worth me looking at this form of heating alternitive to gas
@-JonnyBoy-
@-JonnyBoy- 2 жыл бұрын
Thanks for the video but please no background music or if you do don't make it dynamic to your voice where it gets louder when you don't speak.
@rogerfinch7651
@rogerfinch7651 Жыл бұрын
Had to quit the video. Bad!
@charliespence5962
@charliespence5962 Жыл бұрын
As Adam would say " A simple trick but massive results."
@bibliotek42
@bibliotek42 Ай бұрын
It's REALLY annoying!!!!!
@MrPhillipgraham
@MrPhillipgraham 6 күн бұрын
Yes please get rid of the music!!! So Annoying!
@UrbanPlumbers
@UrbanPlumbers 2 жыл бұрын
Great video again. Background music edited in a strange way, getting louder in speech breaks. (Usually use -28 - 30db throughout)
@cristideac7404
@cristideac7404 11 ай бұрын
Great video. Because of the info found here and other Heat Geek videos I fined tuned my system, quit zoning, no setback temps. My setup is Vaillant turbotec plus combi boiler, 12 year old, 28 KW (non condensing), 8 rads (3 - 1200x400; 4 - 1400x600; 1 -1600x600), 22 type +1 towel rail, in a single series loop, controlled by Tado thermostat with all functions active, connected and configured for ebus protocol. I`ve got a detached 70`s old brick build, 125 m2, thick walls, 450-500mm, concrete floors covered with timber board, both uninsulated; loft has 200mm mineral wool insulation, except a room; double glazing doors and windows. I heat 24/7 at 22,7 C, no setback temp, no zoning, all TRV`s are fully open. I consumed 18 mc3/day, 10 EUR/8.6 GBP (10.01.), with an average outside temp of -3C throughout the full day. Tado modulates the flow of the boiler at somewhat low temperatures 42-52C, for the example above, (the boiler does cycle) and when it`s slightly warmer (0 to 5 C outside) between 38 -46C flow; on a sunny day 36-44C flow. Considering this operation mode do you think I could switch to a condensing boiler or save it for a major renovation I am planning in 2-3 years’ time (full insulation, underfloor heating, may be a heat pump)? Thank you and i hope you extend your heat geeks network outside UK, in the future. Love your work. Greetings from Romania
@dartmoordragon8257
@dartmoordragon8257 Ай бұрын
The best explanation I've ever heard on how to set up a system and been using a heat pump for 18 years!
@1evilpie
@1evilpie 2 жыл бұрын
Thank you so much for this video. Just turned my weather compensation on after it being set to a flat 40 flow temp by the installers 4 years ago. I didn't dare touch it until watching this. Hopefully the on/off cycling will cut down considerably. I have a very low cost 1.30am to 6.30am tariff so actually 'charge' up my floor slab during these hours which normally means the heat pump doesn't kick back in until about 2pm when it's cold outside. It seems to work well solar and home battery usually meaning I don't have to use any high rate electric at all. Might not be the most efficient but it's definitely the cheapest and also gives me a lovely warm floor first thing in the morning :)
@Eamo-21
@Eamo-21 Жыл бұрын
I've been nearly years with ours set to a fixed temp 😆.
@gordonpullan8336
@gordonpullan8336 2 жыл бұрын
Thank you so much. Your short video summarised everything I have learned over the last 2 years since my heat pump was installed. You have clearly explained everything I have been doing wrong, and why my SCOP is only 2.2. I might even ask my wife to watch the video!
@jonazapproductions1683
@jonazapproductions1683 2 жыл бұрын
Very good explanation which confirms what some others have been telling me. Did a test of WC and then constant 45c flow temp but only over a couple of days and no diff on energy consumed or cop but need to check over a longer period, especially as temps always diff. Please, please, please drop the music background though, it is very distracting when trying to concentrate. Thanks!
@serversurfer6169
@serversurfer6169 2 жыл бұрын
Seconded. We're already on our computers; we can play music whenever we like… ✌😜💜
@baz-xl5bo
@baz-xl5bo 2 жыл бұрын
Agree about the irrelevant and distracting music.
@Togfather
@Togfather Жыл бұрын
Wow! Thank you so much for your informative videos. I wish i had seen them a year ago. I had a heat pump installed in June, along with wall insulation, new radiators and solar panels. This was all under the ECO4 scheme, and when the company first came he said that an ASHP would definitely save me money. I live in rural Scotland and was using oiul for heating. The work took two months to complete, and afterwards the house was very comfortable. In September my electric bill rose to £139, which was bearable, but in October it rose to £283! Now I am really worried that the colder months will cost a lot more, and this indicates that the new system will not be saving me money after all. Having watched this video and checked some settings, I now know that the ASHP is not set to weather compensation and they have also given me two zones, each with an external thermostat. I have thermometers in each downstairs room, and the temperatures recorded are not good, with one room as low as 12 degrees, even though the zone thermostat is set to 17 degrees. None of the rooms are recording 17 degrees (15 degrees is the highest). The thermostats do change at different times of the day, and I now believe this could be an important issue, so I plan to change the unit to weather compensation and change the thermoststs to a static temperature all day. I hope this will make us more comfortable and reduce the costs. If not, I will be forced to look at other solutions, as I am a pensioner and cannot afford extremely large electric bills. Maybe I should have only got the solar panels and insulation. Maybe my oil bills and my electric bills will have both reduced.
@adrianpope6541
@adrianpope6541 2 жыл бұрын
I have an Ecodan system that works fairly well (except Mitsubishi think that it is OK for it to totally ice up for 20 minutes before a 2 minutes defrost cycle) and is reporting a SCOP of 5.0 in a very old house. My cunning plan varied the compensation curve every two weeks, plotting the amount of time the system ran against daily average outside temp. I kept dropping the curve until the system ran between 80 and 95 percent of the time. I have trialled fitting low speed computer fans under the two or three layer rads to compensate for the lack of convection at low temps and this has worked very well, with the particular rad turning off more often. These use about 5W total for a 1.5m triple layer rad, and are controlled by a cheap programmable temperature sensor, and I reckon that I will be able to drop the temp by about 2 degrees when I roll them out through the house. A commercial system reports 20% higher output with fans, but those were expensive, and the small high speed fans made the fins in the rads sing. I am also trying polycarbonate secondary glazing to reduce heat loss, and also allow lower delivery temps, with our 200 year old windows. Not that I am obsessed of course.
@HeatGeek
@HeatGeek 2 жыл бұрын
Amazing!
@davelloyd8454
@davelloyd8454 Жыл бұрын
​​@@HeatGeekis this sort of 80-95% run time what we are aiming for? I have SCOP envy!
@Cheadlebiker
@Cheadlebiker Жыл бұрын
I had homeserve fit my Worcester 4000 the fitters left the boiler in the highest settings thank god for heat geek thank you now I have cheaper bills and a warmer home 👍
@TheXeroid
@TheXeroid 3 ай бұрын
Excellent video but please, please, please, no music. It adds nothing but annoyance.
@johntisbury
@johntisbury 2 жыл бұрын
Background music on auto gain is a no no, so distracting. Information is great and on point, spoilt by background music. It's really not needed unless you are in a lift.
@HeatGeek
@HeatGeek 2 жыл бұрын
🤣👍 you'll get used to it I think 🤣 I'll ask to dial back though...
@nealmurphy74
@nealmurphy74 2 жыл бұрын
Great tips, really bad soundtrack which makes the advice lose impact. Can we have a version without the music please???
@HeatGeek
@HeatGeek 2 жыл бұрын
@@nealmurphy74 it's difficult.. young people keep telling us to leave it in and older to take out.. we're kind of caught in the middle 😳
@nealmurphy74
@nealmurphy74 2 жыл бұрын
@@HeatGeek Damn I must be an older person! I don't mind background music if it doesn't intrude, but you can hold a stage with your content without needing gimmicks. Thanks for producing the video.
@HeatGeek
@HeatGeek 2 жыл бұрын
@@nealmurphy74 lol sorry mate. I don't disagree.. its a point of contention for sure!!!
@kag93
@kag93 2 жыл бұрын
Thank you very much for providing this information. I recently moved into a new home with GSHP and had no idea how to utilise it effectively. With this knowledge, I intend to operate a more efficient system. One thing I don't understand is the degree minute setting. Currently, it is set to -60DM. Every 60 minutes, the compressor appears to cycle off and on. The compressor appears to heat up more than the projected flow temperature. Current configurations Current Value 100DM Start Compressor -60DM diff. between additional steps 100DM
@simonaustin1788
@simonaustin1788 2 жыл бұрын
Good vid, very well explained... “3rd party control strangling the heat pump” - love that!
@campbellcopeland
@campbellcopeland 2 жыл бұрын
Really useful - I now understand all the graphs for my Worcester CDI system boiler & Wave / EasyControl Weather Compensation 👍
@vlodski73
@vlodski73 2 жыл бұрын
I really appreciate your videos man ! Tones of important knowledge!
@paulruffy8389
@paulruffy8389 2 жыл бұрын
I have to set my curve at about 1.1 in the winter for required temp, but that doesn't do enough when the temp out side is about 14/15 in the spring and autumn, then I need a higher curve of about 1.5-1.7 to get the rads affecting the temp enough to heat the house up to 20. Something ain't quite right with our set up but we fudge it
@richardgodfrey3708
@richardgodfrey3708 9 ай бұрын
Wow! Does this work for oil boilers (Grant) who offer a weather compensation add-on but not mentioned by the installer. 😡
@MultipipeLtd
@MultipipeLtd 2 жыл бұрын
Blooming great information as usual, and lovely to hear the talk about removing setback as much as possible. Would love to spend some time with you on understanding zoning. Our advice to customer is that zoning (when done correctly) allows for the comfort in each room to be controlled, i.e. your bedrooms can be controlled lower than living areas, under the number 1 rule of continual operating conditions. (mainly talking UFH but does apply to rad's as well). This can also help protect against solar gain a little in south-facing areas. But if removing demand affects the COP, we want to make sure the advice is spot on and harmonious with the rest of the industry.
@HeatGeek
@HeatGeek 2 жыл бұрын
P.s. look for a heat geek on the map.. they'll advise
@enemyofthestatewearein7945
@enemyofthestatewearein7945 2 жыл бұрын
I'd say the purist answer is firstly to try and balance room heat losses & gains using additional insulation and window shading, based on calculations. But as the vid explains in all cases make sure all emitters (underfloor or radiators) are sufficiently sized and correctly balanced to each room load. Then the house should heat fairly evenly without falling back on zone controls. If room losses/gains have large differences and emitters are not balanced you generally end up with the highest loss zone over-driving the the whole system which wastes energy.
@juliandclarke
@juliandclarke 2 жыл бұрын
Fantastic video. I appreciated the idea of lower flow temperature for your ASHP equals better efficiency. But I hadn’t understood the logic behind it - balancing heat demand to heat loss whilst keeping your room at a comfortable temperature. Brilliant explanation. I will be sharing the video and testing the logic with my ASHP. Thank you
@ChapmanPlumbing
@ChapmanPlumbing 2 жыл бұрын
Thanks!!
@DorsetSaferRoads
@DorsetSaferRoads 2 жыл бұрын
We are still on gas (rented) but I have done everything I can to make it efficient. I would love to hear your thoughts on my setup. We don't however use weather compensation as it's and open loop modifier and requires fettling and likely to never get it right. We have a veisman boiler which supports opentherm. Which means I can control the rad circuit temp. Wax TRV suck. Being on the radiator they do not measure (and thus control) room temperature they measure the temperature of the rad. What I have is, In each room I measure the temperature of the air on the opposite wall to where the radiator is. I also measure the temperature of the radiator. I then have underfloor heating actuators on the rad. The whole sense and control is done on a raspberry pi. It looks at the room temperature and uses a PID loop to decide what the radiator temperature needs to be. This set point is used for 2 things, as an input to a 2nd PID loop that controls the actuator on the radiator to control rad temp directly and 2nd to set the flow temperature of the boiler. The system takes all rad set points from all radiators in the house and picks the highest one for the flow temp. What this means is that one of the actuators will be on with the flow temp at exactly what that radiator needs to keep the room warm with the other rads being controls downwards. Overnight the room set points in all rooms drops, then slowly ramps up to the morning when we get up. The angle of this ramp is set fairly shallow so the boiler isn't running flat out to bring the room temps up. The colder it is outside the more the room temp drops so the boiler effectively cuts in earlier. We also have presence awareness so the system knows when we are out and drops the set points and attempts to predict when we will be back and ramps the set points up in a similar way to the day/night does. This system controls the room temp to well under 0.5c often better than 0.1c depending how much the squishy humans open doors! It's running on a raspberry pi running node-red. Boiler controlled with an Arduino mini with an opentherm adapter and graphing done using graphana. The initial setup and tuning of the PID loops took a while to get right. But now it loops after itself. Only thing I do is drop the set points at the end of the spring to stop it heating for an hour on cooler mornings
@HeatGeek
@HeatGeek 2 жыл бұрын
You've done all that and you don't think you can install a dimple weather compensator???? Lololol The funny thing is, if you uninstall all of that and put in a 40 quid weather sensor I think your gas bill would be the same!
@HeatGeek
@HeatGeek 2 жыл бұрын
Also watch our video called 'why not to zone heating systems'
@DorsetSaferRoads
@DorsetSaferRoads 2 жыл бұрын
@@HeatGeek I wrote all that before finishing the video, zoning is actually minimal, ours is more about the fact the radiator sizing is incorrect and a loft bedroom is poorly insulated so needs a heat at times when the rest of the house is warm. The temperatures are the same just the quantity of heat those rooms require is different.
@HeatGeek
@HeatGeek 2 жыл бұрын
@@DorsetSaferRoads you cab get around that with balancing
@DorsetSaferRoads
@DorsetSaferRoads 2 жыл бұрын
@@HeatGeek thats effectively what my system is doing. Balancing only really works for one outside temperature too I think?
@pumpkinhead456
@pumpkinhead456 2 жыл бұрын
Does the same theory apply to my Vaillant Ecotec Plus gas boiler? It has all the necessary controls. Also, if you have multiple zones do you balance them all at once? I can set the curve for each zone! Thanks for taking the time to read and respond to all the messages on here!
@HeatGeek
@HeatGeek 2 жыл бұрын
Hi.. yes but to a lesser degree. With zoning Watch our why not to zone vid
@lionelscott5839
@lionelscott5839 2 жыл бұрын
I have used an outdoor reset control on my five builds , and they work quite well , except when the wind comes up.
@MT-zn6tc
@MT-zn6tc Жыл бұрын
Brilliant. Thank you. I'll search through your videos on the Vaillant Expanded WC now. I think that could be the next stage for us. Running at a SCOP of 3.7 for combined DHW and UF heating.
@anylookup
@anylookup Ай бұрын
A quick question - our nearly 10 years old Vaillant ecoTec 831 Plus has weather comp sensor installed that's showing 6.5 degrees C outside. Therefore, the heating curve for 20 degrees C desired room temperature is currently set to around 0.8 with water flow that should be about 36-38 degrees C according to the installation manual. We have a VRC 470 controller and it's currently set to 20 degrees C desired temp and 19 degrees C setback temp. The room temperature is showing 22.5 degrees C and I have switched Comfort Day mode on to test the system. All radiators' TRVs are set to maximum. Now, in the old days the boiler's burner would not kick in until the current room temperature would fall around or under the set desired temp of 20 degrees C. However, the boiler keeps turning on randomly and starts burning gas when the current temperature exceeds 22 degrees C - is this normal and why it's not waiting for room temp to fall below e.g. 21 degrees C thus burning gas unnecessarily and increasing our bills? There's no errors in the system and I just don't understand why the CH kicks in when there's no need for it and desired temperature already exceeded about 2.5 degrees C.
@andyhunt457
@andyhunt457 2 жыл бұрын
8 degrees outside today.Temp set to 23 degrees.Flow temp is 16 degrees.Vaillant system.
@richardgledhill
@richardgledhill 2 жыл бұрын
Excellent video - our ASHP is going in next week and now I know how to go about setting the temperatures etc! Superb stuff, thanks.
@HeatGeek
@HeatGeek 2 жыл бұрын
Your installer should be doing this not you
@richardgledhill
@richardgledhill 2 жыл бұрын
@@HeatGeek I'm sure they will. I'm a tech geek though so I like to understand what they're doing and why they're doing it :)
@simonposkett1753
@simonposkett1753 2 жыл бұрын
Well done mate, great video👍👍
@TheMindeb
@TheMindeb 2 жыл бұрын
Great and clear video! How I wished to have such simple system :) When you add two floors, wooden flooring(limit temp to 40C max), undergrounf water heating and Nest control of one zone, do not know what degree is needed to balance the system ..
@johncantor4056
@johncantor4056 2 жыл бұрын
Great advice here, and presented well. We need more of this sort of stuff. The only thought I would like to add for any Ecodan owners (and others) is that I think 'Room Target' , (with no outside sensing) can be better than weather comp option, for many situations. In simple terms, this tries to achieve the desired room temp with the lowest flow temperure. I have always like weather comp, but old 'heavy' buildings behave differently to light ones, so it can be tricky to set right.
@giollaliddy5817
@giollaliddy5817 2 жыл бұрын
Hi John. We just got an ecodan and am deciding if to use weather compensation or room target. Can you elaborate as to why specifically the ecodan might preform better? We have done a deep retrofit (approx 80% new build), very highly insualted, airtight and quite high thermal mass, with underfloor heating.
@johncantor4056
@johncantor4056 2 жыл бұрын
@@giollaliddy5817 With simple weather compensation, the heated water temperature setting rises as it gets cold outside, so if there is a sharp frost for example, then the heat pump can tend to 'rev-up'. Arguably, you might want it to 'throttle off' when the air is so cold because the COP is worse. For an old solid weighty building it may easily 'ride' the cold snap. In the case of Ecodan (and some others) there is to my knowledge no option for different day and a night compensation setting. Of course, you might have a cheap night tariff, so the night 'rev up' might be welcome so cheaper heat can be stored in the fabric of the building.. so it depends on the building (heavy or lightweight). The room target control simply looks at the room temperure, and tries to find the lowest flow temperure to satisfy room temperature. Ecodan allow varied target room temperatures over the 24hrs, so this avoids night rev-ups if you don't want them. This control will only work if there is one main area where the reference temperure can be taken, but arguably, the inside is better place to measure. Both highly insulated passive house and solid wall old buildings are 'shielded' from the outside, so weather comp is not always easy to set up. Heat Geek have experience of some of then better advanced controls, which should give good performance in all situations. Back to your Ecodan, I have personally always favoured the room target method if its possible.
@giollaliddy5817
@giollaliddy5817 2 жыл бұрын
@@johncantor4056 thanks for the in depth response. Are you sure ecodan allows for varying room temps during the 24 hrs? I can't seem to find this, which is why I went researching the weather comp. Perhaps it needs a 3rd party controller for this?
@johncantor4056
@johncantor4056 2 жыл бұрын
@@giollaliddy5817 I think there is a schedule, and you can set either on/off, or actual room temperatures over the day. You probably need the main controller configured for 'room target' in order to see this option.
@SkelloRo
@SkelloRo 2 жыл бұрын
@@johncantor4056 Hi. Do you need a Mitsubishi wireless controller installed in a reference room for this to work? I have individual thermostats in each room that are part of the floor heating system, so they control the circuit valves in the floor heating distributors, but are not able to send any temperature information back to the Ecodan heat pump.
@emmaatkinson4334
@emmaatkinson4334 2 жыл бұрын
Surely one's energy bills have the info needed to calculate a house's insulation performance. I use them to work out how much energy our house uses across the year. Mine needs improving before I can consider a heat pump as an alternative to gas boiler. What I will need is to know how to work out the best way to improve it. In my opinion, this specialist expertise is what will be most needed before 2030. The right answers for my house are not obvious.
@HeatGeek
@HeatGeek 2 жыл бұрын
No because it could be a really poorly installed system.. crap cylinder.. High gas cooking.. also does not shown the relative size of rads. Its needs a survey.
@emmaatkinson4334
@emmaatkinson4334 2 жыл бұрын
@Heat Geek OK about some aspects of poor installation, such as a heating system that doesn't provide enough heat when on all of the time. Fitting a heat pump that cannot output enough heat to an inadequately insulated house creates that problem as you have said elsewhere. OK about boilers that shove heat up the chimney too. Being indoors or within one's living space, poor quality cylinders probably give out their wild heat to a nearby room (where the heat is not used to heat water). I should add a caveat around households that cannot afford to heat the home to a comfortable level all of the time. The true heating requirements would be understated in bills. Add an adjustment or a caveat about houses that are not occupied all of the time covered by the energy invoices.
@ciaranciaran100
@ciaranciaran100 6 ай бұрын
Yes of course, the higher the energy consumption on the bills the more important it is to improve energy efficiency of the building and thus have the comfort without wasting money. The choices and specification of these insulation improvements is best done by specialist insulation companies, but you can also use guidelines from the Energy Saving Trust eg that loft insulation should now be 300mm thick. More expensive improvements like better double glazing may or may not be an economic choice (in terms of payback time) and so that is a more specialised decision than the loft insulation. You are right that the specialist expertise is greatly needed, but not all house types are easy to improve.
@hvacdesignsolutions
@hvacdesignsolutions 2 жыл бұрын
Am i correct in saying that everytime the system switches to hot water mode, the weather compensation program is interrupted and the supply temperature goes back up to 50C.
@ChapmanPlumbing
@ChapmanPlumbing 2 жыл бұрын
Not necessarily 50c but to what ever is required for hot water yes..
@wobnoway5692
@wobnoway5692 2 жыл бұрын
All very important! Daikin use weather comp, if you use our room thermostat it combines this with room comp and you can even have water comp....
@aylingtoday
@aylingtoday 2 жыл бұрын
Really helpful video for a new customer in the air source heat pump market. We will definitely be looking for a Heat Geek backed installation having watched your videos but I have a technical question: in a well-insulated house (EPC - B) with a lot of glass and passive solar gain, what is the best way for the engineer to make use of weather compensation to take into account the additional passive solar gain in some, but not all, rooms ? I’m assuming, in part, the answer will be about the location of sensors that communicate with the heat pump. I’m hoping this does not mean the heat pump has to be located in the place of greatest solar gain - the front of the property is south facing (for aesthetic reasons).
@HeatGeek
@HeatGeek 2 жыл бұрын
The heat pump could be anywhere. It uses air not solar! The air is the same all around your house. The first question is too broad I'm afraid. If you have underfloor heating you'll have some self regulation effect
@tobiasparker4214
@tobiasparker4214 2 жыл бұрын
Great vid. Well explained, looking forward to some colder weather (?) To try adjusting the heat curve...
@forestblackberry7046
@forestblackberry7046 2 жыл бұрын
Thank you for a really clear explanation. As someone who currently has a 10 year old condensing gas boiler, would the steps you suggest still be worth implementing, as I thought that the efficiency of the boiler drops off if it isn't on the eco setting?
@HeatGeek
@HeatGeek 2 жыл бұрын
It's unlikely tour boiler has weather compensation, which boiler is it?
@forestblackberry7046
@forestblackberry7046 2 жыл бұрын
@@HeatGeek It's an Ideal Logic+ Heat 24.
@patrickwheeler2646
@patrickwheeler2646 2 жыл бұрын
@@forestblackberry7046 Logic plus do have weather compensation but it is quite basic, they may also have opentherm which could increase efficiency a bit although the modulation isn't the best.
@michellegriffiths8955
@michellegriffiths8955 2 ай бұрын
Hi how do i lower my pressure gauge as i left them open by mistake ad its gone to double i had it on .i've done my radiators but still no movement to lower it
@justinterested5819
@justinterested5819 8 ай бұрын
Shouldnt be the flow temperature being adjusted to inside temperature than outside? In particular, to the room with the weakest radiator (that needs the highest temperature to get the required heating power)?
@twasb2000
@twasb2000 2 жыл бұрын
Brilliant clear and simple explanation. Should you set the weather compensation curve before balancing or vice versa? Thank you
@HeatGeek
@HeatGeek 2 жыл бұрын
Kind of simultaneously..
@prawnk1ng
@prawnk1ng 2 жыл бұрын
I set my boiler flow for 80’c and my house can’t get passed 20.5’c. If I try 65’c I can’t get past 19’c.
@matinphillips9682
@matinphillips9682 2 жыл бұрын
After setting weather comp, you still need to use a house thermostat because the house loses much more heat in a strong freezing wind compared to a still freezing night. If you measure the kW hrs used turning the ASHP off at night, it is considerably less than running it 24 hrs per day even with set back.
@HeatGeek
@HeatGeek 2 жыл бұрын
Both of these things are untrue
@Supplementbenefits
@Supplementbenefits Жыл бұрын
Question 1. What should I set my stat to if the house reaches below a certain temp what should I put?
@HeatGeek
@HeatGeek Жыл бұрын
What's the minimum while feeling comfortable?
@Supplementbenefits
@Supplementbenefits Жыл бұрын
@@HeatGeek for me I am ok at sat 20-21 for the Mrs I think she needs the house on fire haha But if I said heat geek said this then she will have to listen 😎
@Supplementbenefits
@Supplementbenefits Жыл бұрын
@@HeatGeek also just on the back of that i put heating on at 6:30AM to reach 20 but it's not even on 18 yet any reason why it may be slow in warming up or just because it's a older house and open plan? :) - thanks for the response
@marlls1989
@marlls1989 11 ай бұрын
Weather compensation system works terrible in my air conditioning system. It completely ignores the thermal mass and isolation properties of the building. Sometimes it is comfortably chilly outside around 15 degrees, but inside it is still hot at around 25 due to the sun warming all the walls all day and the AC will just work as a fan because it thinks that the heat will radiate instead of doing what I am asking that is to remove as much heat as possible from inside the building.
@wendycarter09
@wendycarter09 2 жыл бұрын
i divert the return water from my rads to a coil in a cylinder containing cold domestic water ,This preheated water is feed to the indirect tank cold taping. .Result indirect is feed with warm water and the boiler return water is at a lower temperature thus fuel savings,
@ooweesaler
@ooweesaler 3 ай бұрын
Excellent info download. What is that background noise?
@lionelscott5839
@lionelscott5839 2 жыл бұрын
I have read somewhere that for every 3degrees F. That you lower the heating water there is a 1% fuel savings , does this work with a heat pump air towater.
@davidw717
@davidw717 Күн бұрын
Wish you'd do this for a Samsung Gen6 ASHP which is called Water Law
@SPDTDL
@SPDTDL 2 жыл бұрын
For the Vaillant, to run without the thermostat switching the heating off, do you set ‘Room temp. Mod.’ To ‘None’ or ‘Temp. Mod.’ ? Thanks
@HeatGeek
@HeatGeek 2 жыл бұрын
Either.. mod will enable the stat to internal influence (more responsive but potentially less efficient)
@sianianni
@sianianni 2 жыл бұрын
Great video as usual. I don't (yet) have a heat pump, waiting for some retrofit work to be carried out before I seriously look at that. I have a total of ten temp sensors feeding into Home Assistant -> influx, so still at data gathering stage. But have been running Viessman gas boiler at 50 flow temp for a couple of months now, have set all TRVs to max, and increased overnight temp from 15 to 17, but only since it's got warmer. I haven't tried adjusting radiators. The house is on the whole as comfortable as it was before I turned flow temp down from 60 to 50 - which is to say when we had a few cold and windy days last month(?) the living room failed to reach target temperature all day, but is pretty much ok on cold still days. I can clearly see where radiators are too big and too small (or set up incorrectly). I've checked that my Vitodens W110 is wired to allow OpenTherm communication, but I don't have weather compensation installed. I use Hive to schedule heating and I'm monitoring Hive boiler on/off data in Home Assistant as well. I also know Hive doesn't talk OpenTherm. My question is : if I get weather compensation, will it work with Hive or will Hive cancel out the weather compensation? I asked the gas engineer who serviced the boiler and he didn't seem to know although he was willing to install a weather compensation unit.
@HeatGeek
@HeatGeek 2 жыл бұрын
Wc will still work. If you have rhe newer 100 or the 200 model get rid of that junk hive and use the intelligent wc
@davewhite5136
@davewhite5136 2 жыл бұрын
Hi...Briliant Video.....just one question regarding initial preperation for setting the WC......when we put all the TRV's on Maximum should we also open up all the lockshield valves as well??
@HeatGeek
@HeatGeek 2 жыл бұрын
No
@michaelsmart8465
@michaelsmart8465 11 күн бұрын
Fantastic info. Thanks
@nicksalini7318
@nicksalini7318 2 жыл бұрын
Great video, well explained!
@HeatGeek
@HeatGeek 2 жыл бұрын
Cheers Nick! Hope your well!
@AdydeAdy21
@AdydeAdy21 11 ай бұрын
For my vaillant boiler what weather compensation do you recomand?
@stevewells2536
@stevewells2536 2 жыл бұрын
Great video, on the VRC700 when room temp mod is set to none will the controller take into consideration the set back temp of 18 I have chosen overnight or will it continue to heat the house to 20 which the current curve does in day time
@ChapmanPlumbing
@ChapmanPlumbing 2 жыл бұрын
Yes it will use set back!! Definitely keep none if it works!
@Flat-Five
@Flat-Five 2 жыл бұрын
With weather comp, do you have to buy the sensor that goes outside separately or does it usually come with the boiler? Looking at a bosch 8000. Also, do they need to be hard wired to the boiler itself? Thanks for all the helpful info. 👍
@Hazellh
@Hazellh 2 жыл бұрын
Great video again. I have a Vailliant Arotherm 7kw, UFH in new build extension (150mm insulation and screed), and oversized triple columns rads in the older part of the house (all single storey bungalow) without TRVs, all set to maximum. Existing floors insulated with 100mm mineral wool, cavities filled, and 200mm loft insulation. I am struggling to get a COP of above 2.7 looking at the controls. Currently have a single zone, with one thermostat set at 17 degrees, and 16 degrees overnight. Thanks to your videos i realized the installers set my hot water tank to 55 degrees... Ive now lowered this to 46-48 degrees (but still have the weekly legionella cycle left on). Weather compensation was set at 0.9, so have reduced slightly to 0.8. This video (correct me if i misunderstood) suggests raising the thermostat 1 degree (so in my case 18degrees), but then reducing weather compensation down so it only reaches 17 degrees? will this not just keep the heat pump on constantly, as the thermostat is calling for heat continuously?
@HeatGeek
@HeatGeek 2 жыл бұрын
On for longer but at a lower output and higher efficiency.. your curve should be around 0.4 I recon.. maybe .5 or 0 6.. do 0.4 first. Also I found jave a buffer or llh it may be unbalanced but that needs a heat geek not homeowner
@Hazellh
@Hazellh 2 жыл бұрын
@@HeatGeek thanks. I do have a buffer tank. Will adjust the compensation curve down a bit and see if that improves things.
@Hazellh
@Hazellh 2 жыл бұрын
@@HeatGeek the controls on mine are showing a target flow temp of 0. It does have minimum at 30 and max at 45. Is this right?
@HeatGeek
@HeatGeek 2 жыл бұрын
@Mr Hazell no, none of that is correct. Who on earth would tell you that? Please get a heat geek in
@Hazellh
@Hazellh 2 жыл бұрын
@@HeatGeek compensation curve down to 0.6 has made a big difference. COP of over 3.5 now. Minimum flow temp is set at 28 and maximum 45. Are you saying this should be different? I’ve paid for a service on this system last year, so will expect the same firm to come and sort the settings (so long as they know what they are doing). Do heat geeks offer the yearly RHI compliant service?
@Haik0
@Haik0 Ай бұрын
I have just recently tried to run my new Vaillant EcoTec plus on WC (on SensoComfort) and I realized that it will just forever run, while it is of course modulating it as needed, but non the less "forever" :) Now my question is, is it ok to run it like all the time ? Or is it ok to set it on "Expanded" so it occasionally shuts off ? These modes: Active, Inactive and Expanded are a little confusing, I can tell the Expended shuts it off when it is reaching the desired temperature but I can not see a difference between "Activa" and "Inactive". What does "Active" do ?T hanks
@aliasgharkhoyee9501
@aliasgharkhoyee9501 2 жыл бұрын
Is there any rule of thumb about how much extra electricity is needed for the increased water flow needed for lower flow temperatures? If lowering the flow temperature of a gas boiler to a level where efficiency and comfort are ideal causes water in your radiators to flow constantly through the night (and perhaps all day as well in winters), I'm thinking that would cause some increase in electricity consumption - likely to be lower than the saving in gas consumption, but still would be good to know how to estimate this.
@HeatGeek
@HeatGeek 2 жыл бұрын
Tiny.. like watts
@aliasgharkhoyee9501
@aliasgharkhoyee9501 2 жыл бұрын
@@HeatGeek Thanks, and is there any way to measure and confirm this? Are there any manufacturers that state on average how much power their gas boilers use to push a litre of water for example?
@qhealy
@qhealy 2 жыл бұрын
@@HeatGeek I was wondering this. So my gas boiler uses 150watts when turned on. I was able to measure this quite consistently with a meter measuring the whole house. This would be 600 kwh of usage if i left the boiler on for 6 months of the year. But because i pay roughly 3 times the rate for an electricity kwh vs a gas kwh unit we're talking 1800 kwh (600 *3). On average I use 6300 kwh of gas a year in my house if I use my thermostats set to 20.5 degrees from oct to march (turning boiler on and off). I could enable opentherm with a heating curve but is it really worth it. Does your video take into account the electricity being used by the boiler. On another note, this is a great youtube channel and have learned loads (or more how little i knew about heating) from your videos. thanks
@HeatGeek
@HeatGeek 2 жыл бұрын
@Brian Healy it's worth it trust me. And electricity is 3x more. But gas is only say 90% efficient.. so its only 2.7 times more. And heat pumps are 350 to 450 efficient Gas boiler electric are tiny. Many thanks
@Allegedly2right
@Allegedly2right 2 жыл бұрын
125 square meter floor plan.EPC score D what size heat pump ball park guess.How is a punter supposed to know if the installers fitted the wrong size pump when they can’t get a simple answer.If you can help great thank you, great channel like it
@HeatGeek
@HeatGeek 2 жыл бұрын
Watch this to answer that question kzbin.info/www/bejne/Y4etgn-ZisSMoLc
@-JonnyBoy-
@-JonnyBoy- 2 жыл бұрын
That's about 1345 square foot so for heating I'd say a 4 Ton heatpump (basing that off 35btu per square ft) How well sealed and insulated your house is and what kind of temps you see in winter in your area will change that though.
@joebennett4634
@joebennett4634 2 жыл бұрын
If it takes 8 hours to reach the comfort level e.g. 20oC from 18oC night setback - you need to increase the flow or the flow temperature?
@HeatGeek
@HeatGeek 2 жыл бұрын
increase flow temp..
@CosminRotaru
@CosminRotaru 2 жыл бұрын
How does this work when the heat pump has an incorporated tank? How do you set the temperature to the tank vs room?
@paulwest5530
@paulwest5530 2 жыл бұрын
Great video and information. Struggling with the compression on the audio though
@MrWLJ71
@MrWLJ71 2 жыл бұрын
VERY informative videos, thank you for taking the time to present. I have a Daikin ASHP and I also have Fan Coil Units. You focus on Rads in your video but do you have any recommendations for settings for FCUs, am I right in thinking they will be different needs than Rads? I am specifically looking to find the LWT for achieving room temps of 21 degC in the daytime. Thank you in advance
@rob-stewart
@rob-stewart 2 жыл бұрын
There's a lot of articles debunking the myth that you should turn off your heating rather than keeping it on low when you're not in the house. It sounds like for heat pumps this doesn't exactly ring true, assuming your not out of the house for days at a time. I'd assume if you are at work on a chilly winter's day you would want to be falling back to your set back temperature rather than having your heating completely off for those hours?
@HeatGeek
@HeatGeek 2 жыл бұрын
That video is due out in a couple weeks time
@rob-stewart
@rob-stewart 2 жыл бұрын
@@HeatGeek Look forward to both it and, due to this video, the commissioning process coming up after my install in a couple of weeks. Might get myself one of those Govee things, surprisingly cheap.
@brianwake100
@brianwake100 2 жыл бұрын
My heat pump has two water temperatures set of different times of day. Would I be better just have one constant water temperature and one a week legionnaires cycle. Or is it better to have a lower temperature then increase temperature every evening?
@HeatGeek
@HeatGeek 2 жыл бұрын
I'll do a video.
@brianwake100
@brianwake100 2 жыл бұрын
@@HeatGeek O wow great thanks. Your videos are very good 👍
@HeatGeek
@HeatGeek 2 жыл бұрын
@@brianwake100 don't worry it was already int he diary!
@jimmyc38
@jimmyc38 2 жыл бұрын
I was surprised you don’t touch on Opentherm. My boiler manufacturer (Ideal, S15 Vogue) advised that Opentherm is better than Weather Compensation. I run an Evohome with UFH and boiler efficiency’s currently at 89% and increasing. I also have 2 x “air to air system” that I run spring and autumn, and obviously cooling in the summer when required
@HeatGeek
@HeatGeek 2 жыл бұрын
Because heat pumps don't use open therm and open therm controls are poor. There is no decent weather compensated openthem. That's why!
@markfrost9087
@markfrost9087 2 жыл бұрын
I was wondering, are there optimal radiator designs for flow rate? Ie does a two column radiator flow better than a four column rad? or is there some other design altogether?
@HeatGeek
@HeatGeek 2 жыл бұрын
Not really.. designer rads ate crap but the others are similar
@nickieredshaw7835
@nickieredshaw7835 2 жыл бұрын
Thanks for another great video
@SuperScubaTim
@SuperScubaTim 2 жыл бұрын
I’m currently testing my heat pump system for the correct heat curve. Bad installation (long story) and I have to set the temperature sensor to water only. The main controller is in a bad location as it’s in a Utility room with a clothes dryer so using the air sensor is not an option. Would you advise moving the controller so to avail of the air sensor also? No matter what heat curve set points I choose, the unit is spitting out heat and house is too warm!!
@johnlesoudeur3653
@johnlesoudeur3653 2 жыл бұрын
Good information and well discussed. I did find it irritating that the camera angle and range is always changing. I know this is done to keep the brain involved but it just gave me a headache...same with music.
@the4elr
@the4elr 2 жыл бұрын
Great vid, thanks! 19:27 does anyone has actual sources on this? I haven't seen any information yet going against advice for frequent L cycles
@ChapmanPlumbing
@ChapmanPlumbing 2 жыл бұрын
Sources on what sorry?
@criggeruk
@criggeruk 2 жыл бұрын
Awesome video, thank you! How long would it take to max all your internal controls, turn the heat pump on and set the compensation curve? A few hours? How long does it take a house to reach equilibrium before you can decide to tweak the curve?
@ChapmanPlumbing
@ChapmanPlumbing 2 жыл бұрын
Depends on the house to be honest.. a few hours to a day or 2.
@criggeruk
@criggeruk 2 жыл бұрын
@@ChapmanPlumbing thanks Adam, not something the installer could do then? I guess they have to go off their calcs?
@ChapmanPlumbing
@ChapmanPlumbing 2 жыл бұрын
@@criggeruk yes something the installer should do, intermittent visits and or calls to adjust..
@chrisjones6542
@chrisjones6542 2 жыл бұрын
@@ChapmanPlumbing jb
@chrisjones6542
@chrisjones6542 2 жыл бұрын
@@ChapmanPlumbing o non mnp
@JD12ish
@JD12ish 2 жыл бұрын
Very annoying background music at the start. Totally worth it though, because the information in the video is amazingly good! 👍
@adrianhancu
@adrianhancu 2 жыл бұрын
Thank you so much for your efforts! I have one question regarding the ambiSENSE smart thermostatic radiator valve. What are the best settings for it to work properly? paired with an Ecovit 255 and VRC700? 1. Should I set Adaptive heat curve? 2. ‘Room temp. Mod. should be set to ‘None’ or ‘Temp. Mod.’ 3. It is absolutely important to have a VR71 to make work properly the VRC700? 4. I don't have any three-way valve - is it bad for the circuit? After HW is ready all radiators get suddenly ultra-hot. The circuit consists of the Ecovit with one zone and VIHR 150. What should I do to stop this effect? The Vaillant instructions are so unclear and no installer knows here hot Ambisense nor VRC700 works. Thank you in advance!
@HeatGeek
@HeatGeek 2 жыл бұрын
Look at our vailant settings video from a week or 2 ago
@adrianhancu
@adrianhancu 2 жыл бұрын
@@HeatGeek Thank you! When you will install or see some ambiSense smart thermostatic radiator valve it will be very useful to read how to customize the VRC700 with them. Once again thank you!
@HeatGeek
@HeatGeek 2 жыл бұрын
@@adrianhancu we don't advise them typically
@manfromdelmonty303
@manfromdelmonty303 Жыл бұрын
Condensing boiler without weather compensation here. My understanding was that for maximum efficiency, my flow temp should be 57 degrees apx. Will going lower bring more efficiency?
@ciaranciaran100
@ciaranciaran100 6 ай бұрын
Yes, there is no magic temperature, whoever said 57deg. Your boiler efficiency increases as you lower the flow temp; mine is often reduced to 33deg at this time of the year. But it can't heat the house from cold at that temp, or at least it can't heat the house from cold quickly.
@paulnichol2578
@paulnichol2578 2 жыл бұрын
Having watched the video I am a bit confused about the target temperature when re-installing the system. The instructions are to put the thermostat and the TRVs to maximum and then adjust the compensation until the target temperature is reached. Where is the system getting the target temperature from.
@MichaelFlatman
@MichaelFlatman 2 жыл бұрын
Just a question about weather compensation.. What happens if you were to go on holiday and want to turn off the central heating (empty house)... When you get back the house will be cold and you will switch the CH on.. With weather compensation it'll only lazily warm up rather than quickly attaining a setpoint (as the radiators won't be that hot). Is there any way around this? Other than modulating using load compensation... Or do some boilers have a weather compensation bypass for this scenario.
@HeatGeek
@HeatGeek 2 жыл бұрын
You would only set it to reduced target temperature. In the last 10 years I've not really had this problem.. radiator output will also be increased at the air to water dt is increased.. and there's holiday timers on decent controls to set it to warm for the day your back..
@nn-qn6mu
@nn-qn6mu 2 жыл бұрын
Hello, Thank You so much for an in depth explanation ; I have a Midea M thermal heat pump that has option on the wired controller between desired water flow temp and desired room temp - does that have anything to do with the weather compensation - meaning if i set the desired water flow temperature the pump will always try to hit that value ? Thank You for your help !
@nn-qn6mu
@nn-qn6mu 2 жыл бұрын
If anyone has any info it would be much appreciated
@silky-soul
@silky-soul 2 жыл бұрын
Hiya, question: my understanding is that the mitsubisi ecodan system (mine is 11kw) does auto weather ompensation when set to use the portable room stat - is this correct? so should i even bother trying to use the curve setting?
@giollaliddy5817
@giollaliddy5817 2 жыл бұрын
Hi Glyn. Curious where you find this info that it does auto compensation when targetted room temp is set?
@MrFlyby34
@MrFlyby34 2 жыл бұрын
Awesome how you explain these matters. Question; can I use a fi Viessmann advanced controler with a Grant oil boiler?
@danoneill8751
@danoneill8751 2 жыл бұрын
Another great video. Am a huge fan. Do you have a physics degree? I do, and the way you approach the physics and the way you handle more subtle concepts (like the not turning off of the rads in less important rooms) is very familiar. If you don't have one, I'd suggest you consider it, not for vocational purposes, just because I think you would enjoy it. One one small point, and not a disagreement, but rather to add a (possible in rare circumstances) caveat: you describe (accurately) the importance of heating as many of the in-envelope rooms as possible, thus increasing emitter output and hence lowering the CH temp needed to get the total power required. And I agree with this... except for if you have a strange house! I do have a strange house and we do have a region which is poorly insulated (drafty as hell) and which we don't use in the winter. While it is 'inside' the house, we are able to block it off reasonably well, with very well sealed doors and curtains and so on. We do have enough emitters in the rest of the property to keep the central heating temp pretty low and still maintain the temp well. So anyway, I would have started with "it depends" but I think that would be misleading - I suspect your point stands in at least 90% of scenarios, so perhaps "it depends a little bit in rare occasions, maybe...". Hope that makes sense. I could go into far more detail, and I did do some very tedious calcs and really don't want to get into in-depth maths discussions (for which youtube is just the worst!) but they tipped the scales just in my circumstance, to turn off the rads in "the cold wing" of the house. It did assume I had very little leakage from the main bulk of the house into that region and I think I have achieved that. Anyway, love the channel, I use the points you make regularly with visitors who just LOVE to bemoan my heatpump when they see it, this especially includes a couple of old plumbers I know (children's friend's parents), who absolutely enjoy heat pump bashing for some reason!
@flatcap6263
@flatcap6263 2 жыл бұрын
Can you tell me your thoughts on thermodynamics and do you think it’s better than solar thermal vacuum tubes.
@ChapmanPlumbing
@ChapmanPlumbing 2 жыл бұрын
you mean thermodynamic pannels? absolute crap please avoid!
@dredmobile105
@dredmobile105 Жыл бұрын
Seems many houses in UK has bad insulation and non low temperature heating systems. LWT 40-50 when -5 - -10 outside OMG. My LWT is 36 when outside temperature is -25 :D And even this result can be improved.
@patregal
@patregal 2 жыл бұрын
Is it cheaper to run a modulating system boiler and a separate water heating cylinder/heat battery or a condensing combi boiler
@patregal
@patregal 2 жыл бұрын
Can that viesmann boiler still condensate at 85 degrees when the outside temperatures are -30 although I doubt this would happen in the uk also I can't understand why all gas and oil condensing system boilers don't have this energy saving devise as it surety it wouldn't take much knowledge to replace the potentiometer with a circuit board with different resistances linked to an outside sensor
@ciaranciaran100
@ciaranciaran100 6 ай бұрын
What you are envisaging is load compensation ie an automatic reduction in boiler temperature when the rooms are getting up to temperature. It's similar in principle to weather compensation but is responding to indoor temperature rather than outdoor. Very worthwhile. I believe Veissman boilers can offer load compensation.
@Eamo-21
@Eamo-21 Жыл бұрын
Brilliant!!! Thanks so much
@aleksandarstojanovski1363
@aleksandarstojanovski1363 2 жыл бұрын
Can I use weather compensation feature if I have buffer tank?
@kevinlee7385
@kevinlee7385 10 ай бұрын
I am currently having a strange situation. The Vaillant air to water heatpump flow temperature didn't increase to the targeted temperature( 41 C targeted vs 37 C on the flow to radiator). Seems this is causing the heatpump part of flow temperature gets very high to near 60 degrees C. The electricity consumption also increased by a factor of 3 when this happened. Any idea how to optimize it? Or it could be a problem with the system?
@ianskeet
@ianskeet 2 жыл бұрын
Absolutely brilliant explanation. Thank you
@mattichu
@mattichu 2 жыл бұрын
This is unbelievably helpful and have shared with other friends with ASHPs. Thank you! Am looking for some advice on our system. All help appreciated.... We have UFH downstairs and Rads upstairs. We have two heating circuits on our Stiebel Eltron WPC10 GSHP but have been advised to run both circuits on the same heat curve because “the rads will come on with the ufh” and “the system only delivers one heating flow and return output feeding both rads & ufh so not practical to have 2 different heat curves”. I feel like we maybe losing the potential efficiency gains of having ufh running at a lower heat curve because we have rads that need a higher curve. Why have two circuits but only one output? Also, there has been mention of a ‘blending valve’ so that the ufh never goes over a particular temp - is this potentially reducing efficiency gains also? I’m in the process of ‘dialling in’ our lowest heat curve over a series of days and feel like I’m getting close, but would like to be able to drop the curve for the ufh. Thanks again for the fantastic content Heat Geek!
@HeatGeek
@HeatGeek 2 жыл бұрын
An electronic mixing valve gives a second flow temp. There are no efficiency gains tho. The unit always has to fire to the highest temp
@mattichu
@mattichu 2 жыл бұрын
@@HeatGeek this seems a real shame and a poor design no? Why would a GSHP have two heating circuits with independent heat curves etc but only a single output that meant the highest flow temp needed had to be met for both?
@terryT-r5o
@terryT-r5o Ай бұрын
I’m wondering whether you could resubmit this video without the background music?
@luckystrike656
@luckystrike656 2 ай бұрын
Is there any downside for a to low heating curve for a combi boiler? I have big radiators fitted before triple glazed wondows and 15cm EPS insulation. My current heating curve is around 0.6-0.7 at 22°C inside Its set on comfort mode and modulating. I feel my boiler is to big 24kw, not mudulating low enough (target temp is 30 and it goes at 38 and then goes down slowly) but is firing more often. Maybe the setting with thwrmostat+external sensor is a bit better. Don't get really any noticeable lower cost of gas.
@prawnk1ng
@prawnk1ng 2 жыл бұрын
My house goes down to 6’c with heating off when it was snowing 2 weeks ago. Apart from loft insulation, what else can I do.
@HeatGeek
@HeatGeek 2 жыл бұрын
Cavity insulation, double glazing, draft exclusion, I've never seen a house drop like that in my 20 years of hearinf I must say..
@Carpe-Diem
@Carpe-Diem Жыл бұрын
How does this work if the daytime temp is say 29 and the evening drops to 10? Can a heat pump adjust to these timescales?
@HeatGeek
@HeatGeek Жыл бұрын
Yes..
@glightsolutions
@glightsolutions 2 жыл бұрын
Great video.
@NickElliottuk
@NickElliottuk 2 жыл бұрын
Is there any chance you could consider making future videos without the background music? I'm not sure why you use it, but I personally don't think it adds anything, and I find it really distracting - especially when the volume auto-increases between your sentences. Otherwise, this is a great series. Thanks!
@HeatGeek
@HeatGeek 2 жыл бұрын
Due to our long term demographic this is likely the format. Thankyou though!!!
@chillmeister
@chillmeister 2 жыл бұрын
I agree with Nick. It’s very distracting having the music blast in during every pause in you speaking. Just set the bed music level during the video and fade up at beginning and end.
@matthewbarnes1461
@matthewbarnes1461 2 жыл бұрын
Is it possible to use weather compensation with 2 zones upstairs and downstairs controlled by a hive? Most evenings I use a wood burner downstairs, would this confuse the system? I have a Daikin 3 H HT with buffer and have had quite a few issues.
@hindy101
@hindy101 2 жыл бұрын
The principle of equilibrium between heat in and heat out, to minimise cycling on a heat pump -> does this same logic apply to a condensing gas boiler? Some gas boilers can modulate right down with smart thermostats -> should those with these units follow the same advice and modulate the boiler right down to keep it on all day at low flow temp?
@HeatGeek
@HeatGeek 2 жыл бұрын
Yes
@patregal
@patregal 2 жыл бұрын
Hi have you done anything on opentherm
@HeatGeek
@HeatGeek 2 жыл бұрын
Our smart stat video goes in to opentherm
What Temperature Should Hot Water Be? | LEGIONELLA Explained
14:26
My scorpion was taken away from me 😢
00:55
TyphoonFast 5
Рет қаралды 2,7 МЛН
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
THIS is Why Your Heat Bill is So High
18:21
Home RenoVision DIY
Рет қаралды 2 МЛН
This Insulation Secret Will BLOW YOUR MIND
16:56
Heat Geek
Рет қаралды 196 М.
3 years living with a heat pump - stats and my main take-away
22:05
Maximizing Your Condensing Gas Boiler's Efficiency
20:56
Urban Plumbers
Рет қаралды 158 М.
Is It Cheaper to Leave Your Heating on Constantly?
14:23
Skill Builder
Рет қаралды 269 М.
Let's Be Real About Heat Pumps!
15:13
Electric Vehicle Man
Рет қаралды 245 М.
11 Easy Ways To Reduce Your Energy Bills | SAVE UP TO 51%!
10:50
Old HVAC industry practices are holding us back and costing us money. But we can fix it.
1:02:18