How to move socket outlet . Extend socket outlet.

  Рет қаралды 197,393

How2D2

How2D2

7 жыл бұрын

Hi . In this video Im showing how to move double socket outlet that is on the ring final circuit into another location using Wago connectors.

Пікірлер: 68
@martinwarner1178
@martinwarner1178 Жыл бұрын
Brilliant, no re-takes on the filming, just a honest show of skills. Thank you. Peace be unto you.
@anasmia8142
@anasmia8142 8 ай бұрын
Excellent, simple tutorial and very informative. Thank You.
@johno7808
@johno7808 6 жыл бұрын
Many thanks for your quick and comprehensive reply.👍
@twig3288
@twig3288 4 жыл бұрын
Top tip: The CPC (earth) wires should not be twisted together in the sheathing. They should be terminated separately in case one conductor became loose and not properly terminated it would not show up on an electrical safety test because it would show continuity even without a secure termination. You need to be able to tug each conductor separately to ensure a sound connection.
@chriswade7887
@chriswade7887 5 жыл бұрын
Great video, very helpful.
@1987yuksel
@1987yuksel 4 жыл бұрын
Thank you very much sir 👍
@bigmanminivan840
@bigmanminivan840 6 жыл бұрын
That’s fantastic how did u know which of the two new cables fitted to which of the two old cables or does it not matter ? Fantastic video thankyou on behalf of everyone who has not said thankyou
@how2d223
@how2d223 6 жыл бұрын
old red wire is new brown - live , old black is new blue - neutral. Thank you for watching
@bigmanminivan840
@bigmanminivan840 6 жыл бұрын
Have you done a video on extending a light switch cable so I can move a light switch please
@Cleggaz
@Cleggaz 2 жыл бұрын
Its the same really done it many times.
@Stoddy2k
@Stoddy2k Жыл бұрын
I have a couple of sockets on the skirting boards. The skirtings are 15 inch high. Not normal. Would I be ok to use this method to move the socket higher up the wall to let’s say approx 40cm higher.
@Akz-xc1gu
@Akz-xc1gu 6 жыл бұрын
one question instead of the two wires to the new outlet would it be possible to use just one wire and splice the 2 cables using the 3 way connector?
@how2d223
@how2d223 6 жыл бұрын
then you create a spur socket instead of socket on the ring but that is fine
@fablan3308
@fablan3308 2 жыл бұрын
So you put the same colour wires trying to do an outside light so two lives go in one of the boxes
@bigmanminivan840
@bigmanminivan840 6 жыл бұрын
Sorry not what I meant I saw the discription on which colour goes with which I mean there are two cables coming off the new socket it has an earth blue and a brown X2 The old one also has two cables (white) with earth black and red x2 (white cables how do you know which ones of the two white cables fits one of the two new gray ones or does it not matter ? Cher’s buddie fit the replie hope I’ve made sense
@rayc1503
@rayc1503 2 жыл бұрын
Really doesn't matter which grey wire connects to which white cable. They were in no specific order in the existing old back box.
@oscillatefn8303
@oscillatefn8303 2 жыл бұрын
Niceeee bro 💯🔥💪🙌👍👏🏅🥇🏆🌟🙏👏💰💰💰😁🙏👏
@mrj4264
@mrj4264 Жыл бұрын
Would this be classified as a spur?
@rajnirvan3336
@rajnirvan3336 4 жыл бұрын
Is it ok to spur off another socket in future from 1 of the Wago box
@bobbyhayday6022
@bobbyhayday6022 5 жыл бұрын
Would this connection be considered 'maintenance free' according to the regs?
@dan0344
@dan0344 3 жыл бұрын
Yeh mate
@rayc1503
@rayc1503 2 жыл бұрын
As the wago's are self clamping and shouldn't need any further adjustment throughout their lifespan. A screw type junction box may become loose due to heat distress and vibrations. For this to be truly maintenance free a cable tire needs to be inserted through the front tab. This is to ensure anyone doesn't try to open it without the form of a tool. As it contains live conductors.
@TavsIsAbout
@TavsIsAbout 3 жыл бұрын
Could you move the socket using wago connectors and wago box, but then bury in solid wall and plaster over the top?
@dommer256
@dommer256 3 жыл бұрын
No.
@GavinLawrence747
@GavinLawrence747 3 жыл бұрын
Absolutely not
@raj080288
@raj080288 9 ай бұрын
Can you bury the connected wires behind a wall and put a blank socket plate on it?
@KingH-nm7dq
@KingH-nm7dq 5 ай бұрын
@@raj080288 yes u can long as it’s covered
@petergee6685
@petergee6685 3 жыл бұрын
Is this legal in the UK?
@Stoddy2k
@Stoddy2k Жыл бұрын
Is this a safe thing to do using this method.
@firsteerr
@firsteerr 5 жыл бұрын
did you certify the extension to this circuit ???
@Christosseventy7
@Christosseventy7 5 жыл бұрын
Hi, great video. I use Wago connectors and boxes all the time, they're excellent. Do you know if it's legal to have them under the floor (inaccessible) if all junction box are supposed to be accessible?
@blakegriffin172
@blakegriffin172 5 жыл бұрын
I think as long as its maintenance free (which wagos are) and in a suitable enclosure (with cords grips) its fine. They don't have to be in a wago box, you could put wagos in a choc box or junction box with compression glands.
@vikingofengland
@vikingofengland 4 жыл бұрын
If inside the box and under the floor or in a wall, they will be deemed Maintenance Free (and BS 5573 compliant I believe), BUT, you then have to downrate the capacity of the connector being used. For example a Wago 222 is rated at 24amps for 2.5mm T and E and will be downrated to 20amps.
@caryj1590
@caryj1590 3 жыл бұрын
8
@raj080288
@raj080288 9 ай бұрын
​@@vikingofenglandhow did you work that out?
@vikingofengland
@vikingofengland 9 ай бұрын
@@raj080288 I think I read that in the regs possibly but that was three years ago now 😰
@olec8978
@olec8978 4 жыл бұрын
And of course dont do this if you dont have a test meter and the ability to test the connections after and understand the readings
@pah9844
@pah9844 9 ай бұрын
Hi. Curious. I understand it’s a ring, but rather than putting 2 cables into the new socket, can you WAGO the 2 existing wires together and then just one other cable to go into the new socket?
@martinda7446
@martinda7446 8 ай бұрын
Yes, one spur to a double socket is allowable for each terminated position on the ring.
@martinda7446
@martinda7446 8 ай бұрын
But its much more acceptable to continue the ring or extend the ring...
@rhysmorgan5009
@rhysmorgan5009 3 жыл бұрын
Make sure you isolate the ring main first, and don’t do this if you don’t have an approved voltage indicator
@danieldoyle7337
@danieldoyle7337 2 жыл бұрын
And a faraday cage, can never be too sure
@martinda7446
@martinda7446 8 ай бұрын
@@danieldoyle7337 Wear wellingtons and rubber gloves in the faraday cage too.
@Mark-gf7yw
@Mark-gf7yw 3 жыл бұрын
Those boxes should have been cable tied shut 👍
@arfurfoxhaike
@arfurfoxhaike 5 жыл бұрын
Lash up!
@nyballa52005
@nyballa52005 6 жыл бұрын
What are those connectors and the box called?
@SteS
@SteS 6 жыл бұрын
Drew Telesca Wago connectors. Available on Amazon.
@doctorelectric470
@doctorelectric470 5 жыл бұрын
Could've just done an unswitched spur to the new socket
@vitorplo2109
@vitorplo2109 3 жыл бұрын
Right👍
@johno7808
@johno7808 6 жыл бұрын
Hi, Is the enclosure box needed by law if used under the floorboards? Or could the connectors be used on their own? Best Regards, Jono.
@how2d223
@how2d223 6 жыл бұрын
Hi Jono. Yes . You need to use the wago box. (The installer connectors need to be within a suitable enclosure. According to BS 7671, “every connection and termination must be enclosed irrespective of the nominal voltage”. The WAGOBOX junction box meet BS EN 60670-01 and BS EN 60670-22.)
@firsteerr
@firsteerr 4 жыл бұрын
You also need a small works certificate
@stevieg7403
@stevieg7403 4 жыл бұрын
Can they be placed into a regular metal two gang socket box?
@rayc1503
@rayc1503 2 жыл бұрын
@@stevieg7403 Yes as long as it's accessible for future maintenance and testing.
@bogdanbarbu363
@bogdanbarbu363 5 жыл бұрын
What is the point of the sleeves?
@Vortiporius_
@Vortiporius_ 5 жыл бұрын
If you mean the earth sleeves, they are required by law.
@overwatch761
@overwatch761 4 жыл бұрын
To keep little copper arms warm during winter buddy.
@josephcronin4209
@josephcronin4209 3 жыл бұрын
Do not think it is code in the US . I will stick with wire nuts and junction box .
@attilagal6672
@attilagal6672 5 жыл бұрын
By regs: if you can’t get access to it it has to be screw retained junction.
@cl0udmc
@cl0udmc 5 жыл бұрын
No. If you can't access it it needs to be a "maintenance free" connection. E.g. like the wago spring levers in this video. A screw terminal requires "maintenance" to ensure it is tight periodically. The cables and terminals will naturally expand and contract with heat thus potentially loosening the screw termination.
@blakegriffin172
@blakegriffin172 5 жыл бұрын
You have it the wrong way round. You can't use screwed terminal strips where there is no access
@d4ve19
@d4ve19 Жыл бұрын
Need to rename, this how to REMOVE a socket, not move it.
@MrAas41
@MrAas41 Жыл бұрын
He moved the socket...
@firsteerr
@firsteerr 4 жыл бұрын
You drilled the hole in the most dangerous place ..right under the nails you have to drill the hole centre of the Board nit enter of two boards a nail or screw could go through your cables are you actually qualified ?? Anyone watching ..do NOT do this get a qualified competent electrician to do your work he will test and certify it ANY diy work will result in your insurance nit paying out in the event of a claim
@ceknott
@ceknott 3 жыл бұрын
Far too slow. We need the basics not real time please
@mausecatchertrap2456
@mausecatchertrap2456 4 жыл бұрын
How many amp connectors for extending electrical socket? 24 or 32 amp? Many thanks.
@how2d223
@how2d223 4 жыл бұрын
these 222 series WAGO are 32A so use them.
Wago lever connectors . How to connect electrical cables
3:19
Зачем он туда залез?
00:25
Vlad Samokatchik
Рет қаралды 3,2 МЛН
🤔Какой Орган самый длинный ? #shorts
00:42
Heartwarming moment as priest rescues ceremony with kindness #shorts
00:33
Fabiosa Best Lifehacks
Рет қаралды 38 МЛН
How to Install a New Electrical Outlet in an Existing Wall
16:01
Proper DIY
Рет қаралды 336 М.
How to Extend Short Wires | Easy Fix Anyone Can Do
6:52
The DIY Guy
Рет қаралды 2,9 МЛН
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Artisan Electrics
Рет қаралды 486 М.
Super DIY Idea ! Bend The Fork Like This And Amaze With The Result
6:02
BIGGEST DIY Mistakes Joining Cables
8:52
The Diligent DIYer
Рет қаралды 220 М.
How to move a socket Oakey & Son Ltd Electrical Services
3:29
Steve Oakey
Рет қаралды 42 М.
Опасность фирменной зарядки Apple
0:57
SuperCrastan
Рет қаралды 3,8 МЛН
Llegó al techo 😱
0:37
Juan De Dios Pantoja
Рет қаралды 49 МЛН
CAA Conversion kit at ZAHAL 🎯
0:14
Zahal Youtube
Рет қаралды 54 МЛН