How To Prime A Gas Soft Wash System

  Рет қаралды 6,461

Proper Exterior Cleaning

Proper Exterior Cleaning

Күн бұрын

Пікірлер: 26
@elitewash549
@elitewash549 4 ай бұрын
Great video man!
@properexterior
@properexterior 4 ай бұрын
Thank you
@josegutierrez9113
@josegutierrez9113 3 ай бұрын
Wow nice video
@MEIKLE02
@MEIKLE02 Жыл бұрын
Thank you so much for this. This is INCREDIBLY useful to people just starting out! Quick question. When priming the metering valve, should we fill those hoses up too? The way I see it: You filled up the inlet hose from the pump to the metering valve, but didn’t fill the hoses up from the metering valve to the tanks. Should we do that? Or could you explain this part a bit more please? Thank you so much!
@properexterior
@properexterior Жыл бұрын
Yeah so good question! The main thing that creates the most headache is the pump itself and the metering system outlet to the inlet of the pump. TYPICALLY, if those two items are filled then it will naturally draw. Now if you have a super long supply hose for both water and Chem you’ll probably have some issues and filling those hoses up with water or chemical would be beneficial. But I would try this method first and then go further if needed
@MEIKLE02
@MEIKLE02 11 ай бұрын
@@properexteriorSorry for the late reply, thank you so much! How big of a deal is it if I can only fill the supply hose up to about 50%?
@properexterior
@properexterior 10 ай бұрын
@@MEIKLE02 so I don’t think it’s that much of an issue assuming everything else is OK. As long as there is the majority of that hose filled, that’s going to help the pump .
@johnthe_don
@johnthe_don 3 ай бұрын
Why does my ar 45 have a valve on the supply to reel and yours doesn’t? Im trying to install mine and that valve is in the way because i need that yellow hose to go upwards.
@properexterior
@properexterior 3 ай бұрын
I got rid of it, it’s a major flow restriction and it’s not necessary for our industry. You can remove it! Then just get a 3/8” male pipe thread x 3/4 or 1/2” barb for your output hose to the reel! North Georgia airless also has these adapters in stock!
@johnthe_don
@johnthe_don 3 ай бұрын
@@properexterior thank you brother 🙏🏻🙏🏻
@adamejose6475
@adamejose6475 8 ай бұрын
Can you make a video on how to delete the gas tank off the small engine and connect it to the bigger tank
@properexterior
@properexterior 8 ай бұрын
Yes it’s on the list of upcoming videos for this year!
@MikeyAR7373
@MikeyAR7373 7 ай бұрын
Just remove your gas tank and the fuel line running to the carburetor or to the fuel pump depending on what motor you have and then run a line from the big gas tank to your carburetor or your fuel pump.
@fredbear2nd
@fredbear2nd 5 ай бұрын
can you run gas soft wash metering valves without the remote on on/off switches?
@properexterior
@properexterior 4 ай бұрын
Yes, you would just have to adjust manually. That’s not an issue at all
@kevinprice7923
@kevinprice7923 7 ай бұрын
What ball valve are you using? How can I build one/buy ty!!
@properexterior
@properexterior 7 ай бұрын
Hydroseal 1/2” threaded ball valve with a 1/2” Mosmatic swivel. Amazon sells the ball valve. Kleen rite sells the swivel Let me know if you have any other questions!
@christopherdodson323
@christopherdodson323 7 ай бұрын
Why did you take off the factor outlet valve? Can you do this process with the factory one on? Thanks
@properexterior
@properexterior 7 ай бұрын
It reduces flow quite a bit. I HIGHLY recommend removing it. It’s the same exact process, all you do is take the black plastic piece off and keep the valve open when priming.
@christopherdodson323
@christopherdodson323 7 ай бұрын
Can you show a quick video short of how you have it set up? Thanks
@christopherdodson323
@christopherdodson323 6 ай бұрын
What fitting replacements did you use on the pump going to the hose reel? I would like to do the same with removing that valve. Thanks
@properexterior
@properexterior 6 ай бұрын
@@christopherdodson323 it’s a 3/8” mpt x 1/2” fpt fitting. Then a 1/2” mpt x 3/4” male barb with three-quarter inch hose
@christopherdodson323
@christopherdodson323 6 ай бұрын
@@properexterior and the top is just a 3/4 check valve to 3/4m x 3/4 barb?
@brianb4390
@brianb4390 7 ай бұрын
You have to do this every morning?
@properexterior
@properexterior 7 ай бұрын
If you want accurate ratios, yes
How to Prime & Flush a Stealth Pro Soft Wash System
20:09
Spraywell
Рет қаралды 12 М.
AR45 Gas Roof Pump Proportioner Build
24:00
All Pro Exterior Services LLC
Рет қаралды 9 М.
Brawl Stars Edit😈📕
00:15
Kan Andrey
Рет қаралды 3,6 МЛН
The CUTEST flower girl on YouTube (2019-2024)
00:10
Hungry FAM
Рет қаралды 42 МЛН
Секрет фокусника! #shorts
00:15
Роман Magic
Рет қаралды 76 МЛН
How to Plumb a Comet P40 gas softwash system.
11:34
Blue Collar Entrepreneur
Рет қаралды 16 М.
Understand SOFT WASHING in 8 minutes (A-Z breakdown)
8:13
Rusty Nesvig
Рет қаралды 3,7 М.
AR45 Outlet Manifold Replacement P/N 43883
17:08
North Georgia Airless
Рет қаралды 820
Comet P40 demonstration
5:45
Readykleen Power Washing
Рет қаралды 10 М.
WHAT YOU NEED TO KNOW ABOUT YOUR SOFT WASH SYSTEM! COMET P40 OFFICIAL “HOW TO MAINTAIN” VIDEO
8:16
Berry Little | Littles Pressure Washing
Рет қаралды 8 М.
AR45 Diaphragm pump - What you need to know - Lessons learned
16:52
House Washing
Рет қаралды 3,8 М.
A Leg Up Pressure Washing Flatbed Build
20:10
Proper Exterior Cleaning
Рет қаралды 4,5 М.
Water Boss VS Red Gun
11:48
Powerful Improvements
Рет қаралды 9 М.
12volt vs gas softwash setup pros and cons
11:13
Beachside Pressure Washing
Рет қаралды 1,8 М.