How to Quiet Pipes With a Water Hammer Arrestor | This Old House

  Рет қаралды 804,607

This Old House

This Old House

Күн бұрын

Пікірлер: 254
@eugene188
@eugene188 6 жыл бұрын
lol. i can't remember the last house i've been to that has an access panel.
@airplanegod
@airplanegod 5 жыл бұрын
Really? My house's downstairs bathroom has an access panel to the back of the tub in the master bedroom, but the house is older. The upstairs bathroom that was redone around 2003 has no access panel.
@GabrielMartinez-bl1hm
@GabrielMartinez-bl1hm 4 жыл бұрын
Most houses built after the 70's weren't built with access panels. This change was due to the use of sheetrock which is much easier to repair than plaster and lathe. Also some jurisdictions may require an access panel but none that I've worked in.
@DeanCF1
@DeanCF1 4 жыл бұрын
It has been required code for a very long time.
@AggressivelyMediocre
@AggressivelyMediocre 4 жыл бұрын
My first house had two. I think people only do it once a disaster happens they don’t want to repeat. Lol.
@bigroblee
@bigroblee 4 жыл бұрын
I've never seen one personally.
@masonwoltz4351
@masonwoltz4351 4 жыл бұрын
"I have a cutaway". Richard always does!
@Johnkoth
@Johnkoth 4 жыл бұрын
Not in the case of the RV unit bathroom shower knobs. He had to make his own cutaway behind a kitchen cabinet.
@dirtbike662
@dirtbike662 2 жыл бұрын
It doesn't hurt to write a date on them. Applies to furnace filter, anode rod too
@peruprofundodance
@peruprofundodance 4 жыл бұрын
Oh! How convenient... we have an access panel.
@jorgeub27
@jorgeub27 2 жыл бұрын
Can those be placed anywhere in the house or do they have to go close to where the sound is coming from?
@hawkesworth1712
@hawkesworth1712 8 жыл бұрын
I would have preferred to see how it sounded when the play in the pipe was fixed before installing the hammer device because now we don't know what fixed the problem.
@elnudos
@elnudos 7 жыл бұрын
Holding the pipe can avoid noise but not the water hammer effect, which would in any case release the inertia into another element of the system.
@jonwhite2706
@jonwhite2706 6 жыл бұрын
agree
@sdmerkr
@sdmerkr 6 жыл бұрын
He totally bumps the wood and makes the same sound. Probably would’ve been fixed by just securing the pipe... start there at least!!
@escaflowne33055
@escaflowne33055 6 жыл бұрын
sdmerkr guess you must be deaf. he said that if he just secured the pipe it probably would've fixed it. however since the pipes go to different areas, adding the arrestors would ensure that the effect would not transfer somewhere else. you donkey.
@jmc5341
@jmc5341 6 жыл бұрын
ri mar who said that? I didnt see that anywhere?
@EyeOnTheTV
@EyeOnTheTV 7 жыл бұрын
Finally a homeowner on this show that's older than 45 and looks like a real person.
@alexmakowski9620
@alexmakowski9620 6 жыл бұрын
EyeOnTheTV hes so cute I want to adopt him as my grandpa
@notafanboy250
@notafanboy250 6 жыл бұрын
lmfao
@itsnotatoober
@itsnotatoober 6 жыл бұрын
Grumpy grandpa over here needs to take his nap already. And up those pills.
@SkylarsTerribleMemes
@SkylarsTerribleMemes 5 жыл бұрын
what
@aaronkrueger7335
@aaronkrueger7335 5 жыл бұрын
EyeOnTheTV, a very overweight homeowner. :-)
@UnbreakableM1nd
@UnbreakableM1nd 7 жыл бұрын
The arrestor is not only there to quiet the noise, the arrestor is really there to prevent damage to your piping. The shockwave caused by the rapid closing of the valves can damage your piping over time.
@CTimmerman
@CTimmerman 6 жыл бұрын
Including loosening screws inside brittle walls.
@kalijasin
@kalijasin 6 жыл бұрын
True.
@floatingbonesjournal
@floatingbonesjournal 5 жыл бұрын
@OneDayAfterAnother No. Arrestors are the simple comprehensive solution. You cannot possibly stop others from turning water on/off slowly -- unless you installed special hardware to do just that. Such things are done for industrial systems, but not in homes.
@johnrambo6265
@johnrambo6265 4 жыл бұрын
23 years pipe still looks fine
@edgarzamora7553
@edgarzamora7553 3 жыл бұрын
Do you need one of those in every water opening or is one enough for the whole house
@TheWGLOVER
@TheWGLOVER 2 жыл бұрын
My plumber just fitted on next to the stopcock. It cured the banging from all the devices.
@joenoname2522
@joenoname2522 6 жыл бұрын
Just so happens theres an access panel lucky
@travishartman5662
@travishartman5662 4 жыл бұрын
Easy to make an access panel or just cut a hole and patch the drywall after.
@artsandoval5598
@artsandoval5598 4 жыл бұрын
makes the commercial easier lol
@larrymoore6640
@larrymoore6640 4 жыл бұрын
He said he heard the sound also with the dishwasher on the first floor and washing machine in the basement. Wonder if that took care of all the problems.
@McFaddis
@McFaddis 7 жыл бұрын
Wow. What a convenient place to have an access panel. Looks like I need to cut one of those
@jeanm7508
@jeanm7508 3 жыл бұрын
Many homes in the states are built like that.
@aaronbaraiya3692
@aaronbaraiya3692 2 жыл бұрын
@@jeanm7508 mainly the older ones though, I'm pretty sure the newer ones don't have them, mine is new and it doesn't have one
@gsent56
@gsent56 Жыл бұрын
Does it matter how close/far you install this to the facets thats causing the air hammers?
@-.._.-_...-_.._-..__..._.-.-.-
@-.._.-_...-_.._-..__..._.-.-.- 4 жыл бұрын
"What do you hear?" "Just water." "As it should be."
@worldview730
@worldview730 3 жыл бұрын
Do these parts have to be replaced periodically? esp. the rubber bladder ones?
@frankpotter827
@frankpotter827 2 жыл бұрын
I have a mini Sioux Chief which I find now after three years I have banging back. Easily screwed on washing machine.
@thebigblackguy
@thebigblackguy Жыл бұрын
Hi. Can this be used for domestic closed loop water central heating installations?
@wbfaulk
@wbfaulk 4 жыл бұрын
I would love to have seen the pipes moving around before the fix.
@mattninja7709
@mattninja7709 3 жыл бұрын
Probably just needed to secure the pipe from moving lol
@maklarus
@maklarus 5 жыл бұрын
next time before stopping the pipe from shaking can you please install the Hammer Device to see how it absorbs the shoks ? and after that secure it with a bolt ? :)
@TLG112009
@TLG112009 Жыл бұрын
The arrestor is not only there to quiet the noise, the arrestor is really there to prevent damage to your piping. The shockwave caused by the rapid closing of the valves can damage your piping over time.
@alvilla701
@alvilla701 10 жыл бұрын
I like it, how long do they last?
@Sku11Leader
@Sku11Leader 10 жыл бұрын
The ones he used have a Schrader valve on them so you can recharge them if need be, so they should last a good long time.
@randomclips9122
@randomclips9122 Жыл бұрын
Would a water hammer arrestor work on a hot water heating system. Eveytime the thermostat shuts the zone valave on the return it bangs the entire home.
@kurtvonfricken6829
@kurtvonfricken6829 4 жыл бұрын
Easy job for Richard. He didn't even put on his little tiny glasses and didn't mention plumbers putty.
@elvis765
@elvis765 2 жыл бұрын
I ordered some to connect to the washing machine connection as when I put a new valve on the machine it started to bang. I assume because the new valve closes faster than the old one did. Is there any style better than another? Nothing else bangs in my house plumbing wise…
@hjwang4477
@hjwang4477 4 жыл бұрын
Maybe after 23 years his wife finally left so he can hear the water hammer noise for the first time
@lesleibrooks7850
@lesleibrooks7850 3 жыл бұрын
haha, you made my day sir :)
@johnsmith1882-x2i
@johnsmith1882-x2i 3 жыл бұрын
She is buried in the basement behind another convenient access panel.
@maximoquinn7218
@maximoquinn7218 3 жыл бұрын
instablaster
@csrboltfan2643
@csrboltfan2643 3 жыл бұрын
@@johnsmith1882-x2i You beat me to it!! I was going to say that.
@JAO981
@JAO981 2 жыл бұрын
Hahaha, you deserve a cold beer Sir.
@domirecitals
@domirecitals 4 жыл бұрын
let's replace the access panel BEFORE we test out if it worked, LOL
@Peter-pv8xx
@Peter-pv8xx 4 жыл бұрын
I'm sure it was tested but they edited it out just like they didn't show him soldering the pipes, in tv it's all about time and not boring the audience.
@Ometecuhtli
@Ometecuhtli 4 жыл бұрын
Rookie mistake
@shelleycharlesworth5177
@shelleycharlesworth5177 Жыл бұрын
I have an Ever Hot hot water dispenser at my kitchen sink. How do I get rid of a water hammer on this thing?
@edschrage3715
@edschrage3715 4 жыл бұрын
The bath in my 2 year old garage has a pinging near the main shut off. System is pex. Sound is intermittent and not necessarily linked to any water running. Any ideas?
@hvac01453
@hvac01453 3 жыл бұрын
Why doesn't my Amtrol air bladder for my well pump, act as an arrestor for the whole system?
@jimk5307
@jimk5307 2 жыл бұрын
The trick is to get these as close to the valve causing the issue as you can; the goal is to catch the “surge” before it reaches the majority of the system. It can lead to adding a number of them in the house.
@jaimedpcaus1
@jaimedpcaus1 9 жыл бұрын
What kind of arrester do I need for a sprinkler system that creates a big bang when the sprinklers close?
@slick-jk6kp
@slick-jk6kp 8 жыл бұрын
same kind that he's installing
@jimk5307
@jimk5307 2 жыл бұрын
You can add same as was installed here or get one that’s normally sold for washing machine add-on arrestor. Just put it between spigot and whatever valve you have on your sprinkler. For example, a hose connected to the irrigation system if it’s a small drip system or one of the ones he installed if you have a larger directly plumbed system.
@jaimedpcaus1
@jaimedpcaus1 2 жыл бұрын
@@jimk5307 Thx.
@Pw6872
@Pw6872 5 жыл бұрын
@ 1:23 Had a silent laugh...
@dadpool0077
@dadpool0077 4 жыл бұрын
Giggity!
@salvatorebrancato4895
@salvatorebrancato4895 3 жыл бұрын
Excellent job
@matthastings6470
@matthastings6470 4 жыл бұрын
Your name is Harvey Doughnut and that is awesome.
@wbmaxon
@wbmaxon Жыл бұрын
Amazing
@crobulari2328
@crobulari2328 5 жыл бұрын
Bend the pipe for clearance like I did. Perfect !!
@Chasepixel
@Chasepixel 4 жыл бұрын
Good job
@dwight.bennett
@dwight.bennett 10 жыл бұрын
What pressure should they be adjusted or recharged to? Is there any difference on how much to charge them with public water vs well pump vs gravity feed?
@Blair88mph
@Blair88mph 9 жыл бұрын
They should be charged to match the water pressure in your house. Your house should be between 40 and 80psi. Under and you will take crappy showers, over you can burst parts on your washing machine.
@kornpop4887
@kornpop4887 7 жыл бұрын
appliances are rated for 60 psi operation
@sohsweegim704
@sohsweegim704 6 жыл бұрын
👍👍👍👍👍Thanks for sharing !
@mastergunj7514
@mastergunj7514 2 жыл бұрын
lol. that noise is nothing compared to mine, and I don't even do it as I live in a unit in the same house with 3 other people. If they close the tap quickly, I get hammered 3 metres from where I usually sit and the noise is similar to someone bashing on my window. 8 months later and its so annoying, and my landlord has tried fixing it using a plumber but it still occurs. So annoying !
@_baller
@_baller 2 жыл бұрын
Oh how convenient an access panel
@celticstephenhill
@celticstephenhill 3 жыл бұрын
Does anyone know if you can install multiple WHAs on the same line to double your protection?
@jimk5307
@jimk5307 2 жыл бұрын
If you really want to, you can.
@CarlosGarcia-ls4hn
@CarlosGarcia-ls4hn 2 жыл бұрын
I have a two story home with multiple sinks, toilets and showers. Each and everyone one them makes the hammer noise. What is the solution? I do believe there is some type of arrestor in the garage with an on and off lever. What is the solution?
@jimk5307
@jimk5307 2 жыл бұрын
That thing you see in your garage with the lever close by is a pressure regulator and the lever valve is the whole house water valve for the water coming in from the street. Advice is to add a small hammer arrestor at each fixture and each supply especially the ones with electric valves like washers, dryers (with steam) and sprinkler timers. Then see if that helps enough.
@tonymanero5544
@tonymanero5544 15 күн бұрын
The general recommendation is to install hammer arrestors near “fast closing valves” like clothes washer and dish washers. As a 1 “big solution” I would install an expansion tank for plumbing, which is installed on cold water line near the hot water heater. Then I would install an arrestor on hot and cold coming out of the hot water heater, because those pipes go to all faucets with hot water. This is done with 3/4 inch arrestors with 3/4 inch tees, either solder or male MIP arrestors. Solder is cheapest, if you know how to solder. MIP pipe arrestors are easily replaced, but they supposed to last 500,000 hammer hits so shouldn’t need replacing. The arrestors are far from many valves, but if the shock backs all the way to the water heater, the arrestors will take the shock.
@conqwiztadore2213
@conqwiztadore2213 4 жыл бұрын
I was expecting to see the cartridge type arrestor
@phildinh852
@phildinh852 6 жыл бұрын
That loose pipe accidentally worked as a dampener so the hammer effect doesn't travel down to more critical parts of the piping :)
@floatingbonesjournal
@floatingbonesjournal 5 жыл бұрын
Damper, not dampener. brians.wsu.edu/2016/05/25/damped-dampened/ If dampness fixed the problem, we'd never need to install water shock arrestors.
@tonymanero5544
@tonymanero5544 15 күн бұрын
The shock is still stressing any solder joints along its path.
@XzTS-Roostro
@XzTS-Roostro 8 жыл бұрын
I hear that same thing from our between the walls of our water heater closet and the guest bathroom
@tripjet999
@tripjet999 7 жыл бұрын
Maybe a ghost?
@jeffreyallen4948
@jeffreyallen4948 5 жыл бұрын
I have a twenty foot hot water return, that I am getting water hammer from, the sound is only noticeable during the winter months. I also notice that the return pipe has dropped 5 inches out of it bracket. will a hammer arrestor solve that issue?
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
Put some new hangers on, and don't let the pipe touch wood.
@billzhang709
@billzhang709 7 жыл бұрын
Do I have to install the arrest near where the pipe gives noise? What if I have access to the pipe that is some feet away from the noise occurs.
@uniquelyqualified3676
@uniquelyqualified3676 4 жыл бұрын
now how do I stop the banging from the apartment upstairs, I was thinking of a murder plot.
@johnhutchison9782
@johnhutchison9782 4 жыл бұрын
Is she hot? Maybe go borrow a cup of sugar from her. Just saying.
@johnhutchison9782
@johnhutchison9782 4 жыл бұрын
@Leopold I'll let you take the progressive angle, LOL. I'm going more conventional. I love T&A 🤘🤘
@NickCBax
@NickCBax 3 жыл бұрын
Just make sure to document it in KZbin comments.
@switchoff64
@switchoff64 4 жыл бұрын
Nice
@ellisdiaz7914
@ellisdiaz7914 6 жыл бұрын
I just saw the video .wondering why you did not strap that hot water line first and them install the choker absorber
@lilturk726
@lilturk726 5 жыл бұрын
Leaving the hot water line loose like that made it easier to fit in his tee.
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
@@lilturk726 although the solder was sloppy looking.
@kenlyneham4105
@kenlyneham4105 4 жыл бұрын
Repeated banging is usually because the pipes were not secured against rattling, as we saw behind the access panel. The most common place for the origins of water hammer is the non-return valve normally installed on the HWU, but also it can come from a clothes washing machine. Usually WMs are connected with flexible hose and their inlet goes through an electrical solenoid shut-off valve. When that valve shuts of the water, the shock wave goes through to the jumper valve in the washing machine cocks and reverberates back causing the hose connection to expand creating another wave back to the valve. The jumper valve acts as a non-return valve. Shutting the valves off after washing is finished, should eliminate it there. My experience is to install a coil of polybutil pipe at the hot water and the cold water connections on the top and bottom of the hot water unit. The expansion is taken up withing the coils. Water hammer reducers break down in time and quickly, if water pressure is high. Mine did because the pressure was 880kp. That's 127.6 psi!
@drrmagneto4176
@drrmagneto4176 8 жыл бұрын
if i have 1/2inch copper tube, what size of T fitting have to be there
@calebharris7252
@calebharris7252 7 жыл бұрын
1/2 in
@lookeywho1287
@lookeywho1287 6 жыл бұрын
If you have to ask this question, do not attempt the repair!
@askhowiknow5527
@askhowiknow5527 6 жыл бұрын
The fitting is already slightly bigger so it’ll fit the pipe, just get the corresponding size
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
1/2" × 1/2" copper by 1/2" female tee
@worldview730
@worldview730 3 жыл бұрын
The bible of maintenance 🙏
@anton_c8gur
@anton_c8gur 7 жыл бұрын
Which one really solved the water hammer? Fixing the pipe or water hammer arrester
@afghandydynamite9767
@afghandydynamite9767 6 жыл бұрын
THE GEAR the arrested.
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
All he really needed was to secure the pipes with the clamps
@iranutter2661
@iranutter2661 Жыл бұрын
Majorly late, but both. The arrestor stops the pipe shaking from change in water pressure. An added measure to stop the shaking was securing the pipe.
@MrSinoline
@MrSinoline 2 жыл бұрын
I have had to replace my piston type anti-hammer device periodically, can't remember exactly, may be every 4 to 6 years. However I have now found out the device (piston type) can be repaired, here is how: 1. After removing, drill a small hole. in the center of the end. (#21 drill for a #10 sheet metal screw) 2. Insert a thin rod through the whole and push the piston all the way back. (The piston has bottomed out, that is why it's not working anymore.) 3. I sealed the hole with # 10 sheet metal screw and a rubber and metal washer. It has been working fine for some time now. (Or you can try to seal the hole with two-part epoxy, let epoxy fully cure. If epoxy fails the piston will prevent water from leaking out!) 4. Reinstall.
@jfdesignsinc.innovationsid1583
@jfdesignsinc.innovationsid1583 8 жыл бұрын
Our rental had a long like an airplane taking off sound buzz or humm... Mostly when the toilet was still filling back up and someone used the sink real quick....was very loud and annoying. Thru whole house
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
Put a new fill valve in the toilet
@zachreyhelmberger894
@zachreyhelmberger894 9 жыл бұрын
Well this is all fine and dandy. But what the heck is the product make and model? I am desperately trying to stop my water pump from cycling on and off 3 times a second every time the frigging washing machine valve slaps shut!! HELP!!!!!!!!
@cowlumbus
@cowlumbus 9 жыл бұрын
+Zachrey Helmberger He told you what they are freak'n google them or look an Home Depot!
@kornpop4887
@kornpop4887 7 жыл бұрын
Water Hammer Arrestor, 1/2 In NPT, 150 psi on Amazon
@anon31415
@anon31415 7 жыл бұрын
Search "1/2 in. Brass Water Hammer Arrester Kit for Washing Machine Valves" at home depot. is that what you need?
@ZZZRSC
@ZZZRSC 6 жыл бұрын
Watts LF150A
@mreneo
@mreneo 2 жыл бұрын
Access panel? How convenient.
@lteht6919
@lteht6919 7 жыл бұрын
"As it should be" Richard needs to get tshirts made, new catchphrase
@EDHBlvd
@EDHBlvd 6 жыл бұрын
Satisfying.
@eianflanagan7767
@eianflanagan7767 7 жыл бұрын
Why didn't they do anything about it 23 years ago
@CTimmerman
@CTimmerman 6 жыл бұрын
Maybe they didn't know how cheap a fix would be and thought they'd get used to it.
@CTimmerman
@CTimmerman 6 жыл бұрын
I see the same in some companies with old managers.
@brandonhorn2007
@brandonhorn2007 5 жыл бұрын
They thought it was just the daughter's headboard
@floatingbonesjournal
@floatingbonesjournal 5 жыл бұрын
As a rule, society is ignorant about phase-dependent frequency-dependent mechanical phenomena. If parents understood the clear and present danger of frequency-dependent phenomena at trampoline parks, the would never ever bring their small children to those parks. Look at what people say here: some suggest the problem can be "fixed" simply by securing the pipes. Wrong!
@kevinroberts8441
@kevinroberts8441 5 жыл бұрын
There was no camera's around
@vicentlu7919
@vicentlu7919 5 жыл бұрын
i have water hammer problem in my house. Anyone in Los Angeles can help to fix the problem for me?
@jacobgarcia48
@jacobgarcia48 5 жыл бұрын
If it is only when you're using the washing machine, then put water hammer arrestors on the valve for the washer. These I'm talking about are easy to install because you don't have to cut the pipe, just screw it on the valve, and then you connect the water hose to the arrestor. There are like 10 dollars at homedepot.
@jacobgarcia48
@jacobgarcia48 2 жыл бұрын
@@dorothymartin8557 yes, it gotta be on both
@darkwaters1010
@darkwaters1010 7 жыл бұрын
Shouldn't those be installed pointing up so the water drains back into the pipe, rather than have water sit inside the thing below the level of the fitting leading into it?
@stevesrt8
@stevesrt8 6 жыл бұрын
Lol
@darrenr1194
@darrenr1194 6 жыл бұрын
drain back into the pipe?? lol its pressurized water line how can it ever "drain" back in unless the main valve is off
@EdwinChenLoo
@EdwinChenLoo 2 жыл бұрын
@@darrenr1194 because of the pressure differencial. The water pressure first increases then decreases back to normal.
@MrCamohoj
@MrCamohoj 6 жыл бұрын
Good job but should have shown how to solder when near to very dry timber with a blow lamp using a heat may and having a fire extinguisher on hand.
@tmittelstaed
@tmittelstaed 5 жыл бұрын
Use a spray bottle and give the timbers around the pipe a good soaking before you start soldering.
@TNtoolman
@TNtoolman 10 жыл бұрын
The original plumber could have avoided any hammer noise when the house was built by extending the feed pipe to the faucets about 6" higher than the "T' feeding the hot and cold and capping the pipe. We have done that for 30 years and never had a noise problem like this.
@johnpacella9519
@johnpacella9519 7 жыл бұрын
Great reply. Sounds like knowledge that has been lost. Surprised TOH is unaware.
@ThePlumber4511
@ThePlumber4511 6 жыл бұрын
I agree. I do that alot.
@kurtvonfricken6829
@kurtvonfricken6829 4 жыл бұрын
Don't they eventually fill up with water?
@TNtoolman
@TNtoolman 4 жыл бұрын
@@kurtvonfricken6829 The capped pipes need to be vertical and the combination of gravity and the capping (no way for the air to escape) prevents the air from escaping. Some plumbers call them "shock absorbers"...
@jimk5307
@jimk5307 2 жыл бұрын
Right, those need to be vertical (air rises) and every once in a while you need to drain the pipes since water will slowly absorb the air and the cylinder will be filled with water. So all in all the manufactured once probably work better for most folks. Also, the ones he installed here look like they are rechargeable via the valve in the “top”. That way you can both add charge to match the water pressure and recharge it if it loses a little air. Same principle as the expansion tank on the water heater.
@chasburns3303
@chasburns3303 6 жыл бұрын
an old plummet taught me to never touch the area of the pipe that will be soldered
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
Yeah, you could melt your hands
@blueribb99
@blueribb99 8 жыл бұрын
I think securing the pipe would have fixed the problem without the arrestors
@pollepost
@pollepost 8 жыл бұрын
Not really because you still got the inertia of waterflow inside the pipe, which causes the "hammer"
@Engineer9736
@Engineer9736 7 жыл бұрын
Then every house in the world would have arrestors. So that's bullshit. Just fixing the pipes would do the trick.
@johnpacella9519
@johnpacella9519 7 жыл бұрын
The REAL solution to this problem is described by Porche924Tim, below. The original piping installation was faulty.
@Mo-rm5um
@Mo-rm5um 7 жыл бұрын
Glenn Watkins You are wrong sir! My caculations can prove it! Therefore, you must go to a mirror and scream "douche bag!" as loud as you can!
@Mo-rm5um
@Mo-rm5um 7 жыл бұрын
pollepost yes really!
@oscarmuffin4322
@oscarmuffin4322 6 жыл бұрын
Why is everybody screaming about water hammer as if it's some sort of big deal. Hammer in a domestic supply isn't going to break any pipes for as long as you live. Large commercial supplies are a different matter but you ain't gonna find any valves that close as fast as a tap in a non-emergency situation in a commercial supply.
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
Whether it's a big deal or not, pipes should be secured with proper hangers and grommets for the ultimate protection and quality plumbing installation.
@jeanm7508
@jeanm7508 3 жыл бұрын
It can damage your pipes
@sarveshpavale3930
@sarveshpavale3930 8 жыл бұрын
does this act just like PRV?
@EvertGuzman
@EvertGuzman 5 жыл бұрын
No
@jimk5307
@jimk5307 2 жыл бұрын
No, a PRV (Pressure Reducing Valve) is to control the water pressure at a reasonable level for the home. Water pressure from the utility can be 100+ PSI which is too high for residential fixtures and hoses. So, a PRV will bring the pressure down to a reasonable level. The anti-hammer chamber reduces the shock from quickly turning off the water, like and electrically controlled valve in a washing machine.
@nelsonechevarria7009
@nelsonechevarria7009 4 жыл бұрын
Good video except for one very very important thing,you forgot to mention that the kind of water hammer arrestor that you installed in the video must be at five psi less than the water pressure in the house.In other words if the water pressure for the house is set at 60psi then the water hammer arrestor must have 55psi.Your video does more harm than good because most people do not bother reading instructions and in failing to read instructions set themselves up for failure.The air valve on that water hammer arrestor is there for a very important reason but most people do not think that far ahead so people tend to overlook such a thing.
@Jedward108
@Jedward108 2 жыл бұрын
Thanks for the tip. What do you do in the case of a well-water system where pressure varies from about 40 to 60 PSI depending on how much water is in the bladder tank?
@tripjet999
@tripjet999 7 жыл бұрын
How would you quiet a noisy plumber?
@kornpop4887
@kornpop4887 7 жыл бұрын
watch out for butt crack
@rodkoehler
@rodkoehler 6 жыл бұрын
I find paying them helps.
@kalijasin
@kalijasin 6 жыл бұрын
@RoadKillzine, Yeah, if he's a British plumber. LOL
@gulopac1
@gulopac1 2 жыл бұрын
When those fail, drywall has to be cut again!
@ShelliLoop
@ShelliLoop 6 жыл бұрын
you got HOT & COLD pipes mixed up. in the access door they are reversed....
@Menmyboy1230
@Menmyboy1230 6 жыл бұрын
No he didn’t ...
@kalijasin
@kalijasin 6 жыл бұрын
If true it does not matter. It's totally "moot". Both arresters will work left or right, hot or cold.
@larrymoore6640
@larrymoore6640 5 жыл бұрын
Richard said the cold water pipe was okay but the hot water pipe was loose (the pipe on the right).
@skplumber1663
@skplumber1663 5 жыл бұрын
Sir hello i m plumber from India
@BigDish101
@BigDish101 6 жыл бұрын
I heard a little thump at the end when he turned the water off...
@frank295
@frank295 3 жыл бұрын
He choose the house with access panel. Lol
@urameshulaganathan1946
@urameshulaganathan1946 7 жыл бұрын
is there posible way to avoid water hammer arester
@mdamon7031
@mdamon7031 5 жыл бұрын
or tighten the washer on the faucet thats banging
@chuckrafiki8649
@chuckrafiki8649 3 жыл бұрын
Isnt that convenient!!!?
@hiyellagal
@hiyellagal 3 жыл бұрын
I live in an apartment and sleep right next to a panel just like this in my second bedroom. The tapping is so annoying and have warned the owner about this, but he's done nothing. Glad I have renter's insurance and hope he does too.
@zachreyhelmberger894
@zachreyhelmberger894 9 жыл бұрын
Sioux Chief AA size mini-rester did absolutely nothing to stop water hammer that triggers the pumptrol pressure switch to oscillate...
@billybassman21
@billybassman21 9 жыл бұрын
***** Did you install them up right? If they are at an angle the top will fill with water and they will be worthless. I have them and they made a big difference. You may also want to make sure all your valves are wide open throughout the house.
@zachreyhelmberger894
@zachreyhelmberger894 9 жыл бұрын
billybassman21 Thanks, Billy! I FINALLY solved it! I cut off the top of the mini-rester and added an 18" long pipe with a cap! I had to bend it a little to get it to fit in the cabinet, LOL! I connected it to a hose bib that is very close to the pressure switch and pump it opened up the valve all the way and it did NOT work. So I closed the valve almost completely and it still did NOT work, but then I started opening it bit by bit and found THANK GOD! that there is a sweet spot. It is a surprisingly narrow range but it is enough to stop the oscillation. Phew!
@cowlumbus
@cowlumbus 9 жыл бұрын
+billybassman21 WRONG. The Sioux can go any direction...these are a piston type design. The old school way of doing it with just a pipe with air will eventually bleed of the air...quicker if not up and down.
@kornpop4887
@kornpop4887 7 жыл бұрын
not as good as the watts brand, the sioux are too small
@michaeljkasnter
@michaeljkasnter 5 жыл бұрын
We don’t use “clips” half strap or hanger
@edlmcnulty04
@edlmcnulty04 6 жыл бұрын
Pretty sure those are st1 expansion tanks. Not hammer arrestors
@workingshlub8861
@workingshlub8861 7 жыл бұрын
first thing he should have done is check the whole house pressure..bad PRV could cause that
@cryptocollector2967
@cryptocollector2967 5 жыл бұрын
Im wondering that about my house 🤔
@jimk5307
@jimk5307 2 жыл бұрын
Bad PRV will certain contribute. The big deal in most places are things like washing machine hoses that while better than they used to be can still sometimes have adverse reactions to both a bad PRV and a pressure surge when there’s a fast valve close. Good call on checking the PRV as part of the process.
@jimk5307
@jimk5307 2 жыл бұрын
@@dorothymartin8557 Yes, if you have water pressure gauge for the hose bib that will work. Put it on the bib (faucet) turn on the faucet for a reading. Leave it open. Open another faucet and let it run and read the gauge. Close the second faucet and record another reading at the gauge. It might take two people since you really want the pressure reading right after turning off the second faucet. That reading is what the PRV is set to hold when no water is flowing, probably should be around 55lbs max. Watch the gauge for a couple of minutes. If the pressure goes up then the PRV is failing and needs replaced or rebuilt. I hope that helps.
@ryanhurbi
@ryanhurbi 2 жыл бұрын
Bet he turned the main water off before cutting those pipes 😜
@teeduck
@teeduck Жыл бұрын
6 months later. It’s leaking
@AndrewMiguelez
@AndrewMiguelez 10 жыл бұрын
Now they're reposting the same videos...
@besikaaa1
@besikaaa1 6 жыл бұрын
Why is he saying hot on the right side pipe???
@Menmyboy1230
@Menmyboy1230 6 жыл бұрын
besika odiakdze cause if you are in the shower looking at the shower valve it’s on the left how it should be
@turbokungfu
@turbokungfu 5 жыл бұрын
I would've wrapped the pipes with a used sock
@jeffreyjohn2037
@jeffreyjohn2037 4 жыл бұрын
Pipe insulation is inexpensive and readily available
@bene6952
@bene6952 3 жыл бұрын
😂 😂😂 how convenient... do it again, okay sounds like it’s coming from this access panel right here next to where I happen to be standing! Easy as that! 😂😂😂 jokers all jokers!!
@DAS-Videos
@DAS-Videos 3 жыл бұрын
And what stopped the noise was securing the pipe, not putting on those high maintenance expansion bubbles.
@csrboltfan2643
@csrboltfan2643 3 жыл бұрын
@@DAS-Videos I think you're missing the point.
@iranutter2661
@iranutter2661 Жыл бұрын
@@DAS-Videos nah dude, it’s the water pressure that caused the hot water to shake loose. The arrestor solves shaking from future pressure change. Securing the pipe alone would cause the pipe to burst later.
@anon31415
@anon31415 7 жыл бұрын
The arrestors cost $160. Scrap metal strip to better secure the pipes...usually nothin'.
@Chuck59ish
@Chuck59ish 10 жыл бұрын
Why did they wait 23 years? It's an easy fix.
@AlphaOneDesigns
@AlphaOneDesigns 6 жыл бұрын
That pants he has on I'm surprised white ppl didnt name it the pipe cleaner Jean sitter.
@bangherlambang3226
@bangherlambang3226 4 жыл бұрын
Awas air nya belum dimatikan seru Air mancur wkwkwkwk
@davidarnsparger5585
@davidarnsparger5585 2 жыл бұрын
TWO Pressure Regulator Values... that's what causes water hammers. Remove one, problem solved.
@mitch9186
@mitch9186 4 жыл бұрын
Just shut the tap off slower
@jeanm7508
@jeanm7508 3 жыл бұрын
Doesn’t help. Google water hammer and read about it
@mitch9186
@mitch9186 3 жыл бұрын
@@jeanm7508 opening and closing valves slowly almost always eliminates water hammer
@csrboltfan2643
@csrboltfan2643 3 жыл бұрын
@@mitch9186 Only problem is not everyone knows this. This should be taught in elementary school.
@victoryfirst2878
@victoryfirst2878 Жыл бұрын
I like your method of screwing the next guy, your fellow plumbers who will have to remove the arrestor when they have to work on the larger pipes for any reason. You should of placed the hammer arrestor higher up the 1/2 inch pipe. You Sir, are most certainly NOT THINKING FOR SURE !!!!!!!!!!! Maybe this is why you are on "This Old House !"
@mixalis11111
@mixalis11111 2 жыл бұрын
Plumber's resolution is not representative to average home - how many houses have an access panel? One in a million? Plumber has practical experience but zero common sense on how others can benefit from this demo. It has been a waste of time for me.
@tlhunter
@tlhunter 6 ай бұрын
It would be a boring video of he spent the whole time cutting the wall open
@lionlinux
@lionlinux 7 жыл бұрын
It's not good he tightening it up and not holding the tube!!!!
@samuelmartin2213
@samuelmartin2213 7 жыл бұрын
FYI anyone watching, this guy is no "Expert" lol hes a paid actor doing what he's told. A true plumbing expert would know that the hammering heard is a symptom, not the issue. That being said, a "shock absorber", is more like a band-aid over a laceration that requires stitches. If you are experiencing water hammer, call an actual plumber. If he tells you its your pipes that are unsecured, or he needs to tear down your walls, call someone else.
@davy1972
@davy1972 7 жыл бұрын
Samuel Martin You should research the "actor."
@samuelmartin2213
@samuelmartin2213 7 жыл бұрын
I don't care, nor do I have to. Just throwing my two cents out there. I know it's not worth much, but I have had customer's tell me "well i watched a youtube video." and when I saw this video I was just couldn't help it. honestly, it's just more job security, however plumbing I feel like should always be done properly due to the health implications of everyone involved.
@davy1972
@davy1972 7 жыл бұрын
The point is he's not an actor. He's been in the industry for years. I watch many of these videos. Do I go out and attempt what they do expecting the same results? Of course not, but it helps to see it done correctly, and gives you an idea of whether to call a pro or not. Back to your expert analysis. This was an ongoing problem for 23 years. Why he didn't open the access panel himself all these years is beyond me. lol
@jej3451
@jej3451 7 жыл бұрын
Okay genius, what is the actual issue then? You spewed out that whole paragraph of self righteous hot air, but didn't let us in on the secret.
@stephensnell1379
@stephensnell1379 7 жыл бұрын
Richard is a professional plumber
@juanwick3569
@juanwick3569 2 жыл бұрын
- "Hey, you think I need a shutoff back there just in case of emergency? The wife hates going down baseme..." "Stop..... It's hammer time....🦹🦹🦹
@alvilla701
@alvilla701 10 жыл бұрын
I like it, how long do they last?
@kornpop4887
@kornpop4887 7 жыл бұрын
forever
Why Water Hammer Arrestors Are SO Important | GOT2LEARN
3:53
Got2Learn
Рет қаралды 2 МЛН
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН
How to Quiet Heating Pipes | This Old House
4:37
This Old House
Рет қаралды 392 М.
Installing a Water Hammer Arrestor for Washing Machine
3:51
Apartment Maintenance Pro
Рет қаралды 4,5 М.
What is Water Hammer?
7:40
Practical Engineering
Рет қаралды 6 МЛН
Plumbers Hate Me For Showing You This!
23:28
Fix This Build That
Рет қаралды 499 М.
Solved! Water Hammer (Save $100)
4:35
MAN the House
Рет қаралды 290 М.
How to Fix Water Hammer | Quick and Easy for $15
7:08
Guy of All Trades
Рет қаралды 41 М.
5 Noisy Plumbing Problems SOLVED!
8:05
Soundproof Guide
Рет қаралды 39 М.
How to Repair a Squealing Shower | Ask This Old House
8:11
This Old House
Рет қаралды 852 М.
inside an American made anti water hammer device
8:23
bigclivedotcom
Рет қаралды 324 М.
Cheerleader Transformation That Left Everyone Speechless! #shorts
00:27
Fabiosa Best Lifehacks
Рет қаралды 16 МЛН