Ty for the video... however if you were also considering critical defects (according your conclusion slide), why a sample size of 1250 (arrow bellow on 0.01) was not considered?
@hoannguyenquoc23413 жыл бұрын
I have question, If you control with AQL 1.5 and check Code L with 200 pcs and find out 8 pcs NG (8/200NG) , after that you continually check until 315 pcs totally and not find out any part NG more (8/315NG), how to judge for this case? Acceptable or Reject?
@avinashdongare54172 жыл бұрын
Very good, Awesome
@lionchen19843 жыл бұрын
great, very useful, thanks a lot
@sajjadabouei67212 жыл бұрын
thanks a lot. saved me
@pangshiekhui23792 жыл бұрын
If I had a lot size of 8, GII inspection level, customer wants AQL=1.0%. Under ISO2859-1, single sampling plan, sample size shall be 13, but my lot size is only 8. Shall I do 100% inspection, or I can still follow under GII inspection level which is sample size = 2?
@RobertWoodman2 ай бұрын
You do a 100% inspection if the test is non-destructive.