also try to make the turbo factor minimum as you can i prefer put 2 in T1 FS well help to improve flow artifact & thank you for amazing knowledge you separated 🙏
@badrlinux67864 жыл бұрын
nice job, good tips like always, FC i use it in knee for the popliteal artery flow reduction, in sometime it work great, sometime not, for ankel olso FC remove folding. thank you for the tips 👍
@chirathsulalith67714 ай бұрын
Can u explain what are techniques use for good c spine sag to see cord without csf flow artifacts
@ping7004 жыл бұрын
im so mindblowned by your ideas 👍🏻
@Help.for.Radiology.Tech8367 Жыл бұрын
Love from Pakistan ❤
@KRIEGInc4 жыл бұрын
Thanks for sharing. It's my favourite channel.
@Nguyen_MRI4 жыл бұрын
Thanks for kindly words and following. Very much appreciated.
@dayaasezar92754 жыл бұрын
Good work
@bernardomartins19644 жыл бұрын
Fantastic!
@FthinoAL3 жыл бұрын
Good job !!
@23232Bing4 жыл бұрын
Keep up the good job!
@SuperMusammil4 жыл бұрын
Really helpful.. Thanks
@abrabr67204 жыл бұрын
Well done bro
@JPearL954 жыл бұрын
Thank you so much for your tips. I love your channel
@mitsaurabh59614 жыл бұрын
To know all about MRCP please see the video kzbin.info/www/bejne/oWati6CudtKFpaM Please do subscribe my channel if you like my video.
@vishaldeshmukh99464 жыл бұрын
Very Nice sir👌👌
@dvalled184 жыл бұрын
Thanks for the video! Just a question: do you usually use a TR around 2000 in your dp fs msk sequences? Better than higher TR (4000, 5000)? Also in 3T?
@Nguyen_MRI4 жыл бұрын
Thanks for the question. Yes tr 2000 should be ok IF using restore pulse. Same on 3T.
@Renjithpaloor Жыл бұрын
For the neck, did you use the sat w/pat 2 and 2 average? Did you use flow comp since in the neck?
@Nguyen_MRI Жыл бұрын
Correct + flow comp slice.
@hieupham97842 жыл бұрын
Anh cho e hỏi cách này mình có áp dụng được với khớp gối không ạ? Can you tell me this way could be apply to knee scan? Thanks
@Nguyen_MRI2 жыл бұрын
Yes. Same principle. Try it for sure 👍
@hieupham97842 жыл бұрын
Thank you so much
@Nguyen_MRI2 жыл бұрын
@@hieupham9784 you’re welcome.
@Li01rad Жыл бұрын
If I’m doing a hip small fov fs axial, I can’t drop the oversampling to 0%, if I increase the average to 2, it’s gonna be too long, what’s the fix for that? If I have comp on and sat HF, and still flow artefact, what do I do .
@Nguyen_MRI Жыл бұрын
Can try to pat higher, rf pulse fast and go lower or tr if possible. Higher bw and lower on tr if possible. Gradient strong and lower on tr if possible. Or lower matrix but pitfalls lower resolution.
@mrmimu4 жыл бұрын
Thanks mate for these serials, and yes we used to use FC but it doesn’t work
@SanalksSanalshaji2 жыл бұрын
Pls give the wrist MRI resolution of all the sequences in dedicated wrist coil 16 channel
@andrewnguyen48274 жыл бұрын
Damn I love it !
@jim84397 ай бұрын
I have found that increasing PE steps to 100% also reduces ghosting artefact quite well.
@Nguyen_MRI7 ай бұрын
That's nice.
@aijusudhakaran52744 жыл бұрын
Thanks bro 💝😘
@Mike-c9g6iАй бұрын
New MRI Tech here - I don't get how changing the averages helps with Flow?
@radtech90173 жыл бұрын
How many sequence do in whole Body Mri and how to do sir
@Nguyen_MRI3 жыл бұрын
kzbin.info/www/bejne/jWG9ZoCNmruAack Depends on sites. But we usually do t2 dixon coronal and coronal dwi
@sheikhatif9022 Жыл бұрын
what flow comp. do? what are the benefits of flow comp. ?
@Nguyen_MRI Жыл бұрын
mriquestions.com/flow-compensation.html
@mohamadhassan77584 жыл бұрын
👍👍👍
@9cobil2992 жыл бұрын
Would this work for an axial PDFS on a thumb aswell? Love your vids!
@Nguyen_MRI2 жыл бұрын
Yes it should. Please try out. Worth it
@9cobil2992 жыл бұрын
@@Nguyen_MRI Thanks alot, will let you know how it went!
@9cobil2992 жыл бұрын
@@Nguyen_MRI It turned out great, cut scan time down a minute, increased the matrix and eliminated alot of pulse artefacts. Thank you, Bac!
@Nguyen_MRI2 жыл бұрын
very nice. Happy to hear that 👍👍👍👍
@vitthaltambade410 Жыл бұрын
Can u tell me what is use of PAT
@Nguyen_MRI Жыл бұрын
mriquestions.com/what-is-pi.html
@josepc42323 жыл бұрын
Hi Bac, what’s PAT2 means?
@Nguyen_MRI3 жыл бұрын
Hi. It means you accelerated by 2. Check this link: www.ncbi.nlm.nih.gov/pmc/articles/PMC4459721/
@suhaimiss73224 жыл бұрын
How about to reduce flow artifacts in brain scan especially post contrast scan? Tqvm... 😂
@Nguyen_MRI4 жыл бұрын
Several approaches can be done here. 3D / 2D with black blood. Mprage GRE. Etc.
@suhaimiss73224 жыл бұрын
Used to T1 TFE or BRAVO, but it’s have prep IR, but most my Radiologist are old timers 😀😀, so add the in plane T1 with MTC or T1FS ...