We're redoing our entire school garden, and will have 16 zones + all hooked up to a wi-fi controller (Rachio Iro)... I've done several valves to replace at home; our upcoming project mimics your video w/ multiple valves + so, thanks... this video is very helpful to help visualize the steps, spacing between valve boxes, etc. Thx!
@Iscaper8 жыл бұрын
+JBinCalifornia Thanks for watching.
@farmerbob3395 жыл бұрын
Nicely done. Now I am no longer discouraged from doing systems from scratch. Only wish they had the valves with Unions on them I did my last overhaul. I ended up putting regular 1" unions inline. AND Drain Valves!! I had them all over so once pressure was lost every thing would drain. Grandpa took them all out. I have had to do some major repairs because of this. Will fix it soon.
@spelunkerd12 жыл бұрын
Thanks Kerry. When I set my multimeter to measure AC voltage I measured 25V for voltage drop both at the solenoid (while running) and at the controller -- dumb mistake for me to think it was DC. In my community a new solenoid is $14 and a new valve is $57 so I just replaced the solenoid. My old solenoid had high resistance that bounced around, suggesting a bad internal wire. The new solenoid resistance was 24 ohms, the bad solenoid was 30-90 ohms. Success! Thanks for your advice. Dave
@oceansidehigh10 жыл бұрын
We're fixing our sprinkler system too, and this video (along with your other ones) has been incredibly helpful. Thanks so much for posting!
@Iscaper10 жыл бұрын
Thanks, I appreciate the comments.
@robertstone54769 жыл бұрын
Very educational and well explained. I thought the only step missing was your checking for leaks after everything was replaced! I wish all valve had unions; that would make life a whole lot easier.
@Iscaper9 жыл бұрын
Robert Stone I did check for leaks but didn't show it in the video. Unfortunately Rain Bird discontinued the valve with unions shown in the video. Not sure why they did it but they did.
@joannalayne86886 жыл бұрын
Thanks for your video...the rubber mallet was just the trick when I was replacing my manifold....also instead of dish soap, I used hair dryer for about 60 seconds on my poly tubing and connectors slipped in very easily.
@Iscaper11 жыл бұрын
If you're referring to the fitting between the 2 pre-built manifolds, it is not a coupling it is a 1"x1"x1/2" tee (SxSxT) that has an automatic drain threaded into it.
@alextoufanpur26299 жыл бұрын
So patiently explained. Thank you friend!
@Iscaper9 жыл бұрын
Alex Toufanpur Thanks Alex for watching.
@JoseMichell9 жыл бұрын
iScaper1 Can you tell me where to purchase Dura parts to build the sprinkler manifold? I broke one of the connectors and I'm unable to find a store in Regina. Since you are wearing a Rider's hat I assume u r from Sk. Thanks.
@Iscaper9 жыл бұрын
Jose Michell You can buy them online here: www.sprinklerwarehouse.com/Standard-Valve-Manifold-Parts-s/456.htm
@crzy110009 жыл бұрын
Jose Michell You can get from consolidated turf in Saskatoon
@JoseMichell9 жыл бұрын
Thank you for the information.
@van_dutch5 ай бұрын
This is incredible work, def motivating me to take on my 4 valve system. The job in this video would be about 20 trips to Home Depot for me.
@Iscaper5 ай бұрын
Rain Bird has discontinued the union valves shown in the video. I've started using Action manifolds instead. Here's a link to a video using an Action manifold and Rain Bird 100DVF sprinkler valves: kzbin.info/www/bejne/jaHIpaWlhdymZ5I
@progers50199 жыл бұрын
Great jobs, I really enjoyed watching you work through that. What a difference. Easy to listen to.
@Iscaper9 жыл бұрын
Irvin Rogers Thanks Irvin.
@tomkane26 Жыл бұрын
All of the dirt must be put back into the hole, so there is no divot around the valve box. Those bleeder valves needed gravel around them. Before cutting wires mark which wires go to what area and mark them with masking tape, and the valves that you are changing so you don't have to reprogram your controller.
@roberts.95998 жыл бұрын
Just a suggestion, but you may try Oetiker clamps vs. screw clamps. Also, I tend to refrain from using automatic drains aka King drains. I've found that root intrusion and the amount of water they waste isn't worth the benefits.
@spelunkerd12 жыл бұрын
Yes, I've heard the same thing from others, who describe the whole valve costing just a little more than the solenoid. But up here in Canada there are strange differences, partly related to duty and additional transportation fees. The valve is an irritrol 2711 APR but the solenoid is made in Mexico so it should be duty free. Mail order is often a problem here because of additional customs and shipping fees. Overall I'm glad it is fixed, and it's fun to understand how it all works. Thanks again.
@SDRWeddingsEvents-hh5ld6 ай бұрын
You have given me the confidence to attempt this. Thank you
@Iscaper6 ай бұрын
Good luck!
@josephperrone19797 жыл бұрын
The Bob Ross of irrigation. Good job
@Iscaper11 жыл бұрын
Very kind, thanks for taking the time to leave a comment.
@Iscaper11 жыл бұрын
I bought them from my Rain Bird distributor. Unfortunately Rain Bird discontinued the valve. It was my favorite valve. You can still get the DVF without the unions.
@Iscaper12 жыл бұрын
Start by turning the stop & waste valve on, make sure it is completely on. Then look in the stand pipe that covers the valve. Notice if there is water filling the pipe. You could have a leak on the downstream side of the stop & waste valve. If you don't notice anything there then check all of your sprinkler valves for leaks. If the flow dial is spinning slowly, it can be difficult to isolate the leak. The most likely culprits are the sprinkler valves or your stop & waste valve.
@cspill992 жыл бұрын
Can you help me with installation? old copper system with pvb in the basement. how can I rerun this? I have pictures.
@Iscaper11 жыл бұрын
Where I live the backflow preventer has to be installed before the first set of sprinkler valves. You are correct, these aren't anti-siphon valves.
@heroknaderi3 жыл бұрын
I enjoyed the video. I also have 9 zones at my home and still working ok the only thing I am curious about is how to find hidden valves because I could never find them my system was installed in the 1980s and I believe the installer directly buried the valves and didn’t use valve boxes. I always like to know where they are for future maintenance. Very helpful video.😁👍
@Iscaper3 жыл бұрын
You may have to rent a line locator to find the valves.
@CostaMesaPhotography9 жыл бұрын
Very nicely done...if you're not already teaching, you should consider it--you're good.
@Iscaper9 жыл бұрын
CostaMesaPhotography Thanks, I appreciate the feedback.
@Iscaper12 жыл бұрын
The valves are Rain Bird 100DVFUU union valves. Of my suppliers who carry Rain Bird, only 2 of them carry this particular valve. I'm not sure if you'll have better luck with Rain Bird suppliers in your area.
@Iscaper12 жыл бұрын
I'll say. We ate some great sea food in Victoria. The lady at the hotel we stayed at said there is a running joke in Victoria that you had to be newly wed or nearly dead to live in Victoria, and that the city was trying to change that image. I didn't notice any of that when we were there.
@toekneemoment3 жыл бұрын
This video is so well done. Thank you for taking your time to put this up on youtube!
@Iscaper3 жыл бұрын
Thanks, I appreciate the feedback.
@DazedNConfuzed5810 жыл бұрын
I am having problems with my system & this video was very helpful. Thank you! In fact my valves are the same ones here.
@Iscaper10 жыл бұрын
Thanks Paully.
@JoseRivera-hl6ve9 жыл бұрын
Keep making those video! Thank you for your time and effort in making this project so easy to do.
@Iscaper9 жыл бұрын
Thanks Jose, I appreciate the feedback.
@Iscaper11 жыл бұрын
Depends on what your system piping is. If your supply line piping to the valves is 1.25" or 1.5" I would install 1.5" valves. If your supply line is 1" you would be ok installing 1" valves. You don't want to reduce the available flow in gpm (gallons per minute) through the valves to the sprinkler system.
@kevinjohnson976110 жыл бұрын
Very nice video, I love the dish soap tip. thanks for sharing
@Iscaper10 жыл бұрын
Thanks Kevin for the feedback.
@Iscaper12 жыл бұрын
Hi Dave. I've done the multi-tester on the wrong setting also. I'm surprised there was that much difference in the solenoid and valve cost. Usually it's only a few dollars. What kind of valves do you have? Glad you solved your problem. 95% of valve trouble I run into is the solenoid. KT
@omutakaeddie10 жыл бұрын
Every body should learn how to use this type of irrigation.
@Iscaper12 жыл бұрын
I went to Rain Bird's site & looked up their specs on solenoids. They are 24VAC 50/60Hz solenoids. Inrush current is .30A (7.2VA) at 60Hz. Holding current is .19A (4.6VA) at 60Hz. Coil resistance is 42-55 ohms. Even though the solenoids are 24VAC, most timers I've encountered put out around 28-29VAC. The lowest voltage I've seen on a timer & still have it open a valve solenoid is 18VAC. continued
@Sholay483 жыл бұрын
Thank you. Its very comprehensive. Could I ask you whether we can build the manifold and valves over ground on a wall and then box it so that they do not get muddy and at the same time easier to get access to and maintain? Thank you.
@Iscaper3 жыл бұрын
You could but I wouldn't. Sprinkler manifolds are generally designed to be installed underground. For me the reason is aesthetics. It would be hard to build a manifold above ground and have it look good. If you're using PVC pipe to build the manifold the PVC doesn't do well in sunlight. Also bumping a manifold under pressure with something like a lawnmower or other lawn equipment risks damage to the manifold.
@Iscaper11 жыл бұрын
Drains are King auto drains. They are much more reliable than drains from years past which were ball and spring types and would tend to get debris in the drain and leak. These drains have a rubber diaphragm with filter cloth over the drain. I've had very little trouble with them. When the zone pressure hits the drain (7psi) they shut off and when the zone shuts down they open and begin draining (slowly). Rocks-gravel around drain are only necessary if you have heavy clay soil.
@Iscaper11 жыл бұрын
I got the shoes at REI. They are Vasque Gore-Tex. Awesome shoes.
@ragerdl6 жыл бұрын
Long but seemingly complete. Nice job :)
@mythril49 жыл бұрын
I build my manifolds out of close coupled 2" PVC (I use 2" smooth to 1" thread tee's), then I pipe in the city water usually with 1&1/4 inch poly pipe from a double check valve. To clarify however, the reason I use 2" PVC is for smoother valve operation and primarily for pump/city water combinations. The pumps I use can run around 4 zones at the same time in many cases, but this is only possible with the 2" manifolds. My personal pump will run 25 3.0GPM rotors at the same time if I want it to. The city water requires one zone at a time. Let me tell ya, close coupled 2" PVC manifolds connecting via brass nipples to the valves and then to the poly pipe. While they not only look sexy (chuckles) but they are very easy to work on as everything stays in perfect alignment and is rigid. I normally use DVF valves from Rainbird. It's usually not necessary to remove a valve entirely, you simply replace it's guts if it fails. On 1" poly fittings or smaller I use 2 pinch claps per fitting, and anything over 1&1/4" poly I use 3 pinch clamps per fitting. No leaks and no service failures until you are much much older (provided you blow the system out for winter).
@MixinGreen-uk6id5 ай бұрын
nice job, i noticed u didnt use tephlon tape. But Ive seen other guys use it. Im assuming its not required . Anybody have suggestions?
@Iscaper5 ай бұрын
Rain Bird discontinued valves used in video. They were union valves that had an internal o-ring so teflon tape wasn't required. I've been using Action manifolds and Rain Bird 100DVF sprinkler valves since. Here's a link to a video replacing the manifold with affiliate links for the parts. kzbin.info/www/bejne/jaHIpaWlhdymZ5I
@johnvandyk25923 жыл бұрын
Pretty sharp the way you duct taped your primer and glue together. That's a tip I'll remember.
@Iscaper3 жыл бұрын
Thanks John for watching.
@spelunkerd12 жыл бұрын
Hi Kerry. I'm wondering what the normal spec for a typical solenoid valve should be for voltage drop and amp draw. If the solenoid is removed, what is the (DC?) voltage diff to ground at the device? I've got what I think is a bad solenoid but it has been hard to prove since it does work with a 9V battery when under no load. I've swapped it for other solenoids, and also I swapped the wiring with a known good valve and both tests say the solenoid is bad. Connections are clean.
@bigheadmarkie2 жыл бұрын
your tutorials are awesome!
@Iscaper2 жыл бұрын
Glad you think so!
@wjackstl9 жыл бұрын
hello Kerry, I just wanted to offer a suggestion for you. when retrofitting a system from poly to pvc, I will get out my heat gun and (lightly) heat the poly, first. then I will insert any 2" to 3" (or as long as you want) off-cuts of 3/4" pvc into the 1" poly. after it's heated, it slides right in and will harden around the pvc, but I still like to add a hose clamp for good measure. I have found this to be cheaper and easier than purchasing those transition adaptors, not to mention using up scrap pvc....plus there's the added benefit of having more pipe inside the poly than the transition adaptors. just my 0.02 ¢ take care
@Iscaper9 жыл бұрын
+Wesley Jackson Good tips, thanks for posting.
@raidherrideher6 жыл бұрын
I like ideas like that, fewer transitions and a stronger connection. this works because poly is a thermoplastic meaning it's formed/molded & REMOLDED via heat just like PVC. there are heat snakes that make up to 4" pvc into rubber noodles for odd angle connections and help avoid issues of kinking from too localized of a bend via heat gun heating of the pipe (the bend happens all in 1 short section vs. a longer sweep)
@mormonsniper518310 жыл бұрын
Excellent. Very nice installation and explanation. Pro level. Thanks!
@Iscaper10 жыл бұрын
Thanks for watching.
@Iscaper11 жыл бұрын
Thanks, this installation turned into a project.
@therealandrewcano5 жыл бұрын
But I like this video alot. As an irrigator myself I really dig this video
@lorenzobatt69024 жыл бұрын
Excellent explanation and video. Thank you!
@johnmariano477 жыл бұрын
Thanks and Well done! ' Subscribed too. The 100DFVuu may be obsolete at this time as I cannot find them online. Are the unions themselves detachable? Thanks.
@owlexS11 жыл бұрын
This was an awesome video. Thank you for sharing your knowledge.
@robertglidewell94945 жыл бұрын
EXCELLENT video
@ShortFlic4 жыл бұрын
Good video. Well done, thanks
@Iscaper12 жыл бұрын
Thanks for the feedback.
@therealandrewcano5 жыл бұрын
I've never seen hose clamps used on poly , but I've also only used poly for drip (plants and trees)
@Iscaper12 жыл бұрын
Test your voltage from the timer. If you have the 28-29 volts I talked about earlier, everything is good to the valve. If the valve won't open and close properly your problem has to be the solenoid. Buy a new valve and replace the top half of the old valve with the top half of the new valve. I suggest this because solenoids often cost as much or more than a complete valve. Let me know how this works.
@curiousmelody11 жыл бұрын
What type of automatic drain do you use? I think there are different types and most irrigation professionals that I have talked with do not like to use them. We have never winterized or system and never had any problems. I do know at the end of the line which slopes down we have an automatic drain valve. Do you recognize rocks around the drain? Great site that I've subscribed too.
@Iscaper12 жыл бұрын
Interesting, I can buy a Rain Bird DV valve for $11, and if I just want the solenoid it is $10. What part of Canada do you live in? We just went to Vancouver Island and Vancouver. What a beautiful country!
@tracyr55946 жыл бұрын
yes, is cheaper to buy new valves than valve parts...
@chuckweir164910 жыл бұрын
nice job; ready to take on my project now.
@Iscaper10 жыл бұрын
Thanks Chuck and good luck.
@sigguy13618 жыл бұрын
Love that easy setup. Nice work. No tef-tape for the threads?
@Iscaper8 жыл бұрын
These sprinkler valves have o-rings that keep them from leaking when the nuts are tightened. No teflon tape is needed on the male adapters.
@sigguy13618 жыл бұрын
Looks very neat and professional, especially when it's all finished and covered. Good job!
@sigguy13618 жыл бұрын
Another question for you: at what point would you consider making a move from 3/4 to 1" pvc for your runs, or is it unnecessary for residential? I guess with well placed, quality heads (like the ones you are using), 3/4 is sufficient?
@Iscaper8 жыл бұрын
Usually most homes are fed with a 3/4" water meter so even though there would be a little less friction loss running 1" pipe on the zone lines the cost increase isn't worth it and there isn't the flow from the water meter to support it. I do like to do the manifolds, supply lines to the valves in 1" because most lawn sprinkler valves for residential applications are in 1". If a home has a 1" water meter I would definitely run 1" pipe to the heads.
@sigguy13618 жыл бұрын
iScaper1 Roger that. Thanks for the help!
@johnlynch833011 жыл бұрын
Great video, the repairs I have to do seem a lot more manageable...
@josedurand113210 жыл бұрын
Great video! very professional, help me a lot. Thanks
@Iscaper10 жыл бұрын
Thanks Jose for the comments.
@josedurand113210 жыл бұрын
Why do you use two liquid?
@Iscaper10 жыл бұрын
Jose Durand Two liquids? I don't understand.
@Iscaper10 жыл бұрын
Kenneth Webster I get it, thanks Kenneth. It's primer and glue. Primer prepares the pipe and fittings so that the glue will have a good chemical bond.
@Iscaper11 жыл бұрын
Small repairs I normally do by the hour plus materials. A lot of customers what to know up front what the costs will be so then I would give them an estimate.
@brianamarie82058 жыл бұрын
ha John what do u tk of the wireless timers ( Remote Typ )
@roballison507610 жыл бұрын
Very good and very helpful for my home project. Thanks.
@Iscaper10 жыл бұрын
Thanks for watching.
@angelmarte95393 жыл бұрын
Excellent video
@Iscaper3 жыл бұрын
Thanks Angel for watching.
@29nettels12 жыл бұрын
Question for you sir and thank you for the videos. My water meter has a little spinner on it and it's slowly turning. When I shutoff the water to the sprinkler system, that little spinner stops, so I think the manifold is leaking. When I take off the cover to expose the zone valves, there is stagnant water in there. Not a high amount of water but maybe half full. This is probably a leak before the valves since I haven't used the sprinkler system in awhile?
@tracyr55946 жыл бұрын
This was a very long project. I bet you were there all day.
@spelunkerd12 жыл бұрын
Thanks for the quick response. I'll look into that. Dave
@pac1la6 жыл бұрын
Very informative video, thank you.
@gustavoriquelme1011 жыл бұрын
Gracias por compartir el conocimiento desde Argentina, Neuquén.-
@Iscaper11 жыл бұрын
Thanks Gustavo for commenting.
@manangservices9188 жыл бұрын
hilo whats that? silinoid valve? 220 volt why burried in the ground it safe? i make stab out water meter semilar to your project but 12 inch in the ground so easy to operate and less maintenence with directoy anyway tnx nice vids
@Iscaper8 жыл бұрын
+albert pagliawan Sprinkler valves are 24 volt.
@roadrunner1233 жыл бұрын
Another great video!
@Iscaper3 жыл бұрын
Thanks Road Runner!
@jambatvee3803 Жыл бұрын
This is perfection!
@Iscaper Жыл бұрын
Thanks Jamba, I appreciate the feedback.
@larrykluckoutdoors82274 жыл бұрын
Good video. Thanks
@omutakaeddie10 жыл бұрын
Thank u 4 the good idea u hv given .
@Iscaper10 жыл бұрын
Thanks Eddie.
@musicteacherbuilder11 жыл бұрын
My old system has 1.25" valves. It seems modern Rainbird valves are now 1", 1.5", or 2". Can you replace a valve in a 1.25" system with a standard 1" valve?
@cristobalpacheco42025 жыл бұрын
Did your 12 wire timer wire reach to all the different valves or did you have to add wire extensions? Thanks
@Iscaper5 жыл бұрын
I cut short lengths of timer wire and looped them up where the valve boxes would be.
@cristobalpacheco42025 жыл бұрын
Thanks, I really enjoy this type of video
@Iscaper11 жыл бұрын
No special reason other than my sprinkler material supplier carried the hose clamps but not the pinch clamp.
@johnkosheluk104111 жыл бұрын
Good eavining kerry i allways watch your videos and learn a lot i am estimiting a spr revamp job i have a question do u est a job by the hr or give a price on the job after u look at it your in put would b gerat
@urtoodvs473010 жыл бұрын
Good stuff! Thanks for the help!
@Iscaper10 жыл бұрын
Thanks for the feedback.
@Iscaper11 жыл бұрын
Good luck. Report back on how it goes.
@Iscaper11 жыл бұрын
Thanks for the comment.
@sharpelawncare538110 жыл бұрын
I like using action brand manifolds and Hunter PGV valves.
@Iscaper10 жыл бұрын
Good tip, thanks for posting. I like Action manifolds also. I've also used Dura manifold parts.
@AdamMargie4ever9 жыл бұрын
Great job on the video very helpful!!!!
@Iscaper9 жыл бұрын
Thanks.
@danielmcdonald943310 жыл бұрын
Thank you sir! Very helpful
@Iscaper10 жыл бұрын
Thanks, I appreciate the feedback.
@Russ9388 жыл бұрын
excellent video, thanks
@Iscaper8 жыл бұрын
+Russ Krayer Thanks Russ.
@anon24146 жыл бұрын
Wow work of art
@davidh204911 жыл бұрын
Should there be some backflow prevention device installed ? These are not anti-siphon valves, right?
@d7c7d12 жыл бұрын
Excellent video. Thank you.
@jasonbranson4484 жыл бұрын
Thanks, learned a lot
@garciaslandscaping112810 жыл бұрын
What is the part number for the rain bird kit that you are using?
@Iscaper10 жыл бұрын
Rain Bird part number is: UVMS3DVFS. Problem is Rain Bird discontinued the 100DVFUU valve so I don't know if this manifold kit is still available.
@vilsan.r.98754 жыл бұрын
How many years before the hose clamp rots away?
@arturozavala86773 жыл бұрын
Thats at least a $1500.00 Dollar Job in todays money👍
@carlissimo6411 жыл бұрын
Nice tutorial. Thanks.
@None-ij7zz6 жыл бұрын
Why would you use clamps that over time rust? They leak on external garden hose and most likely worse in dirt.
@sphudson12 жыл бұрын
Can you please tell me the name/part# of those valves and where I can purchase them? I believe you said RainBird. Thanks in advance.
@jwhitaker150710 жыл бұрын
Nice Keens!
@Iscaper10 жыл бұрын
Keens?
@seanduncan61217 жыл бұрын
iScaper1 maybe the shoes?
@marinejarheade95 жыл бұрын
I was wondering how to connect the common wires together on a nine valve manifold since the valve wires are to short to reach together?
@Iscaper5 жыл бұрын
Connect the wires that will reach to a longer single wire that would connect to the common wire running to the timer.
@constantbuzz6 жыл бұрын
no leak test before back filling?
@kalamelliel4 жыл бұрын
Where do you get your fittings from generally
@Iscaper4 жыл бұрын
Rain Bird quit making the union valves a few years ago, I'm using Action Machine manifolds now. Here's a link: kzbin.info/www/bejne/jaHIpaWlhdymZ5I