In This HVAC Video, I go over How to Know What Refrigerant Freon is in the Air Conditioner, Heat Pump, or Refrigerator. I explain the difference in Pressure and Saturated Temp Readings when the System is Off and Equalized. I explain the difference in readings of the Gauge Set between R-22, R-410A, M099, R-407C, NU22B as well as when Noncondensables are mixed in the system. I also explain what a severe leak looks like. Supervision is needed by a licensed HVACR Tech while doing this as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video
Fieldpiece ST4 Dual Temp Meter- amzn.to/2wc1ME3
Yellow Jacket Refrigerant Manifold Gauge Set amzn.to/2aenwTq
Refrigerant hoses with valves amzn.to/2aBumVI
Blue Vapor Yellow Jacket Gauge amzn.to/2Ju7pan
Red Liquid Yellow Jacket Gauge amzn.to/2sSFmGH
Quick Coupler for the Gauges amzn.to/2sTk8Ze
Refrigerant hoses with valves amzn.to/2aBumVI
Yellow Jacket Manifold Gauge Set amzn.to/2vLVkV9
Compact Ball Valve Attachment for the end of the Refrigerant Hose- amzn.to/2KUisW8
Quick Disconnect 90 degree attachment amzn.to/2MMtVcg
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos/Articles
• R-22 and R-410A Operat...
• R-410A AC Unit, Checki...
• Checking the Refrigera...
• Checking the Charge of...
• HVAC Training Basics f...
• Finding Target Superhe...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicet...
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicet...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtoo...
Refrigerant Charging Book and E-Book: www.acservicet...
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicet...
Our Newest Articles: www.acservicet...
Try our HVAC/R Quizzes! www.acservicet...
Our Other Resources: www.acservicet...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicet...
Our Tool List on Amazon: www.amazon.com...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtoo...
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.c...
Apple Podcasts: podcasts.apple...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #manifold #digitalmanifold #buyer #purchase #manifoldgauge #gaugeset #hvactips #hvactools #refrigerant #r22
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 65
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is the Link for the FieldPiece ST4 Dual Temp Meter- amzn.to/2AhR6ph Here is the Link for Yellow Jacket Refrigerant Manifold Gauge Set amzn.to/2aenwTq Here is a link to Refrigerant hoses with valves used in the videos- amzn.to/2aBumVI Here is the link to the Blue Vapor Yellow Jacket Gauge- amzn.to/2Ju7pan Here is the link to the Red Liquid Yellow Jacket Gauge- amzn.to/2sSFmGH Here is the Quick Coupler for the Gauges- amzn.to/2sTk8Ze Here is the JB Quick Connect Test Gauge High Side- amzn.to/2ruQb0l Here is the JB Quick Connect Test Gauge Low Side- amzn.to/2qR0utM Here is a link for RectorSeal Bubble Gas Leak Detector amzn.to/2ckWACn Here is a link to the JB 6 CFM Vacuum Pump amzn.to/2nqbvo8 Here is the link to the Appion Valve Core Removal Tool- amzn.to/2uYr8WL Here is the link to the CPS Vacuum Micron Gauge- amzn.to/2v1nM3O Here is the Link to the Appion Blue 3/8" to 1/4" Vacuum Hose- amzn.to/2uYlVyc Here is the Link to the Appion Red 3/8" to 1/4" Vacuum Hose- amzn.to/2uYg6Ro Here is the link to the Yellow Jacket 1/4" by 1/4" heavy duty hose straight- amzn.to/2umtcod Here is the link to the pack of 25 C&D valve cores- amzn.to/2J1lurm Here is the link for the C&D Valve Core Wrench, Container, and 3 valve cores- amzn.to/2EVGkps Here is the Link for the newer UEI DL479 Multimeter with temp sensor- amzn.to/2jtsUbJ Other tool links can be found in the video description section. Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech All of the ACSERVICETECH Playlists- kzbin.info/door/OZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
@luislujan8715
@luislujan8715 Жыл бұрын
You are going to the HVAC heaven bro. Thanks for teaching us better than the local community college. The temperature is perfect there. I'm sure you'll like it.
@NMranchhand
@NMranchhand 6 жыл бұрын
I’m really glad that you’re not shy about overlapping information that you have previously covered. First, because that’s the way people actually learn in apprenticeship, and you know that, and that’s why you’re such a good instructor. Second, because each time you cover it you add some additional nuance and say things a bit differently, which helps the mind re-approach the information from a fresh direction. Thanks.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Very nice explanation! You are hitting all the aspects that are important to me! Great to hear that it is coming across that way! Thanks
@jackpast
@jackpast 6 жыл бұрын
Thanks Craig. Never forgot this lesson. Can't tell you how many time P/T relationships have helped me understand what's going on with even non-HVAC systems in industry.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Jack!
@MC-mq8mh
@MC-mq8mh 6 жыл бұрын
Spending another day with my notepad watching your video. Thank you for the video.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Nice, thanks MC!
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thank you very much Bill Gringo!
@Bobster0007
@Bobster0007 6 жыл бұрын
Hello to the viewers. I dont know the OP at all. Let me say this, this guy is providing real value in these videos. The least we can do is click one of his amazon links. Even if you dont buy the product / tool that the link goes to, he will get a small commission from anything you buy on amazon for a short period of time until your cookie times out in amazon. This does not cost you any money at all even as this guy gets paid a little. His videos are excellent IMO and i have already bought several items through his affiliate link. Step up and do the right thing.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thank you very much Bob! I really appreciate your support! It means a lot!
@leoashrae4199
@leoashrae4199 6 жыл бұрын
Great video. This is good, need-to-know, information for all new techs. I would also like to add that if you've allowed sufficient time for the gas to equilibrate and reach saturation temperature, and you find that none of your numbers seem to make any sense, you may have a system with mixed refrigerants in it. This is why I always ask the customer if someone else has looked at the job before me. I've had more than enough trouble with home owners buying "freon" from auto-zone, and jury-rigging a "hose" to get it into their condensing unit. If someone has put R134a automotive refrigerant (especially the junk with "leak-proofing and "tracking dye" in it) into an R410a or R22 system, there is nothing you can do but recover everything (being sure to put it into your special recovery bottle that you keep in the truck just for "mixed refrigerants"), do a complete vacuum test, and recharge with the required factory charge of the correct refrigerant. If you have any suspicions at all about mixed refrigerants, DO NOT try to correct the problem by adding more of the proper refrigerant...it won't work.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Perfect statements Leo, thanks!
@keithhoward8651
@keithhoward8651 6 жыл бұрын
I really enjoy the way you take time to describe how to check each thing. Thank you so much for that. Stay Blessed.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thank you very much Keith! I appreciate it!
@cedricdaryll
@cedricdaryll 6 жыл бұрын
Thank you for that excellent Knowledge you've shared.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thank you Truth Will Reveal!
@marshalljohnson7028
@marshalljohnson7028 Жыл бұрын
This video is a life saver. I build industrial Chiller modules so I have some knowledge on AC units, but I'm not a service tech for residential units haha. Thank you!!
@jddr.jkindle9708
@jddr.jkindle9708 6 жыл бұрын
Another Excellent described learning video.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks JD!
@1shagg420
@1shagg420 2 жыл бұрын
This is such a useful video! I have a recovery jug in almost certain has a bunch of good r22 in it but it's not labeled! Now I can check with decent certainty! Thank you for this!
@electricboogie709
@electricboogie709 6 жыл бұрын
I cried it was so good.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
HA ha nice Boris, thanks!
@padilla7019
@padilla7019 2 жыл бұрын
Another important information that will help me out to troubleshoot
@garyomglol
@garyomglol 5 жыл бұрын
Awesome video! I had a refrigeration company from craigslist took a look at my walk in refrigerator's condensing unit because it was bubbling in the site glass. 2 techs show up. By deciphering my compressor code, they both concluded that it was an R12 compressor. Here is the funny part. Both techs were arguing about which refrigerant to use. There were no indentifying labels anywhere. One tech wants to use r134a while the other said he's going to use "hot-shot" as an upgrade, adding $150 to my bill. They don't have a refrigerant identifying tool. I asked them what's the cheapest way they can do it. They said they can top off with hydrocarbon12a/152a. Really? They said hydrocarbon is a bigger molecule and will stay in the system longer versus the 134a, but there's a catch. They wont write me a receipt if I chose the latter. My question is: which would you use (hydrocarbon or r134a) to top off just to have the machine work for another month or 2, so that I have more time saving up for a new system. Ofcourse no one is supposed to mix refrigerant, that I totally understand. But installing r134a to top off a system when you don't know if r12 was initially in the system kind of defeat this. Thanks in advance for your answer.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
The best thing to do is to recover the existing charge, vacuum and weigh in a new R-12 retrofit refrigerant. We don't mix refrigerants. If they want to use R-134A then they would need to cut out the compressor to drain the oil and replace it with POE, otherwise the compressor may burn out because R-134A won't carry the mineral oil well, thanks!
@chenchris7576
@chenchris7576 6 жыл бұрын
Thanks another useful video
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Chen Chris!
@whitesheatingairappliancer7101
@whitesheatingairappliancer7101 6 жыл бұрын
Great video thank you.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Ron!
@SoLowKaspar
@SoLowKaspar Жыл бұрын
my only question is how can you tell what refrigerant the system runs on when it is "low" on refrigerant. After taking HVACR classes. They never mentioned this, nor did I ever ask because I didn't think I would come across this problem. But this problem is extremely common where I work. Our senior who works here with his EPA universal also doesn't know how to tell other than him using his memory (he's been here for 14 years). This is an apartment complex we work at. If neither of us can tell what the system uses. We usually end up replacing the whole system. We also understand that is usually the best case since the system shouldn't be going low anyways and 99% of these that we replace with this issue are more than 10 years old. Some 15+ years even. So while low on refrigerant or completely empty from a faulty/worn valve core which we replace, how can you know what refrigerant they use without any labeling? All labeling has withered away and has been erased by the sun. All condensers are on the flat roof of our buildings.
@4littlechicken
@4littlechicken Жыл бұрын
Thank You
@acservicedaytona386portora3
@acservicedaytona386portora3 6 жыл бұрын
👏 Bravo brotha... Always a great video.....
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks AC!
@thanpan1276
@thanpan1276 3 жыл бұрын
YOU ARE A BLESSING TO WORLD
@geojor
@geojor 6 жыл бұрын
valuable information, thank you ...
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks
@user-fn1dw8pu4y
@user-fn1dw8pu4y 6 жыл бұрын
Here’s where I get my Sunday education
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Mason, I appreciate the comment!
@acrepairnearme
@acrepairnearme 6 жыл бұрын
Cool tips! Very helpful! And how to determine if system charged with mixed refrigerants? What I have to see to determine it? What it can cause? Thank you so much!)
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks Tapch! Leo put a great comment out on that in the comment section. The sat temp when off may be higher or lower than the refrigerant that is supposed to be in there depending upon the refrigerant that they added. You will notice roughly the same thing as when the system has noncondensables in it most of the time unless there is 134a added. You may think that the system is very low on refrigerant in that case because the sat temp is low when off but when you are running it, and adding refrigerant, the mix does not act like it normally does with superheat decreasing and subcooling increasing. You would just stop there and recover into your mixed refrigerants recovery tank. Thanks Tapch MC!
@acrepairnearme
@acrepairnearme 6 жыл бұрын
Thank you for the detailed explanation. Thank you Leo.
@wnnwilliamsniinortey7742
@wnnwilliamsniinortey7742 9 ай бұрын
My outlet does not have any paper on the,so can't know if R22 or R 410A
@toddbehrends1373
@toddbehrends1373 6 жыл бұрын
Could you check the units in the fall, to determine the refrigerant in the system? I am sure that all the units on my rental houses are 410A, but just to make sure. All the systems are running well, now. But just to check.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
You could check what type of refrigerant it is in any temp. To check the charge, you would wait until a 70 degree day though, thanks Todd!
@bobalbert2828
@bobalbert2828 6 жыл бұрын
Awesome video! I have a question though. How about if there is no indication on the unit that let's you know how many pounds of R-22 to put in. Is there any way to tell how little is too little or how much is too much?
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
You won't know how much refrigerant is supposed to be in the system. You are going to have to guess the weight. Just weigh in less than you think and then start the unit up and add as needed using superheat or subcooling, thanks
@whiteboyfromernul
@whiteboyfromernul 6 жыл бұрын
can't really go with a labeled txv,I came across 3 units in 2 weeks,r22 on the condenser label with r410a on the txv's and the units actually had r22 in them
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
That is not good, Those txv's would need to be changed out unless they were electronic ones. How was your subcooling, hunting, and delta T? Thanks Tipoblanco! That is a shame someone did that!
@throttlebottle5906
@throttlebottle5906 6 жыл бұрын
probably shady business practice, as in done on purpose so the compressor burns out and they end up replacing condenser soon ;)
@coolmandude1000
@coolmandude1000 6 жыл бұрын
This is how most HVAC wholesale suppliers who accept used refrigerant test recovery tanks to determine what refrigerant is in the recovery tanks.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks coolmandude1000!
@diegomagallon321
@diegomagallon321 6 жыл бұрын
There is a 4,000 thousand dollar machine that I’ve seen yellow jacket sell to identify which refrigerant you are dealing with.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Yes very expensive and not many techs carry that in their service truck. I just wanted to go over the content that is in the epa 608 test for figuring out what refrigerant is in there, thanks Diego!
@ivanestrada9646
@ivanestrada9646 6 жыл бұрын
Thank you for the video ! But wait !!! Don’t you have to shut off the service valves? Let’s Say your outdoor temp is 100 and your indoor temperature (inside the air handler) is 80. With valves opened you cannot go by just your outdoor temp because there would be a 20F difference within the same sealed system. It’s like heating up that tank to 100F on top and freezing the bottom to 32F. (I am exaggerating just for sake of argument) you would have a mixture of temperatures within one container. I wonder what was the indoor temperature in this house?. Maybe it was close enough to outdoor temp that it didn’t affect your result. But it is still important to at least me mind Full of it. What are your thoughts on this? Anyone.....
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
It was close in temp during the video but the higher temp area would still exert a higher pressure on the whole system at equalization, thanks!
@krysisn
@krysisn 4 жыл бұрын
Arfortenay
@plumbjitsu7097
@plumbjitsu7097 6 жыл бұрын
Has anyone here ever twinned some Lennox split systems
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Are you talking two systems that are the exact same size or are you taking just two different systems?
@plumbjitsu7097
@plumbjitsu7097 6 жыл бұрын
AC Service Tech LLC two systems exactly the same
@user-vb8jl6nf4k
@user-vb8jl6nf4k 5 жыл бұрын
Hey Craig I sent you an email but no answer regarding to my purchase about the book thanks
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Hamid, my email is info@acservicetech.com I don't see any email and it looks like you purchased the ebook a while ago. Please email me and I would love to answer any questions you have, thanks!
@Riomadness
@Riomadness 6 жыл бұрын
Don't say that. Retrofit help.
How to Use the Free Refrigerant Slider P/T App & R-22 Retrofit Comparisons
7:12
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
Они так быстро убрались!
01:00
Аришнев
Рет қаралды 2,9 МЛН
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 36 МЛН
How To Use AC Gauges
26:34
Benjamin Sahlstrom
Рет қаралды 1,2 МЛН
How To Add Refrigerant / Freon To Your Window Air Conditioner      R22 & 410a
12:19
Troubleshooting With Sat Temps, Superheat, & Subcooling! 5 Possible Problems!!
18:48
Charging R-22 into an Air Conditioner that is VERY LOW on Refrigerant!
25:13
AC Service Tech LLC
Рет қаралды 254 М.
HVAC Tips to Avoid Vacuum Problems! Top 15!
17:35
AC Service Tech LLC
Рет қаралды 211 М.
AC LOW on Refrigerant! How To Know!
7:16
HVAC Guide for Homeowners
Рет қаралды 81 М.
Explaining Superheat and Subcooling to Your Apprentice!
14:14
AC Service Tech LLC
Рет қаралды 602 М.
Capacitor and Hard Start Myths Busted
28:41
HVAC School
Рет қаралды 225 М.
HVAC 128 Recovery most used but slowest
10:43
Love2HVAC with Ty Branaman
Рет қаралды 77 М.
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,2 МЛН