No video

How To Add Refrigerant / Freon To Your Window Air Conditioner R22 & 410a

  Рет қаралды 65,932

The DIY HVAC Guy

The DIY HVAC Guy

Күн бұрын

1/2" 5/8" Saddle Valve: amzn.to/3WjFttv
1/4" 5/16" 3/8" Saddle Valve: amzn.to/4cylZam
#1 Source for HVAC equipment: hvacdirect.com
Use my discount code 1MJTDLG4GM70 for an extra 3% off!
All my favorite HVAC tools: www.amazon.com...
Do you own a service business and need a customer management software?
Housecall Pro is the BEST CRM for small businesses and can save you so much time with scheduling, onboarding new customers, sending estimates etc.
Use my link to get 50% off the first 2 months: housecallpro.p...
Join our channel membership to gain access to exclusive HVAC training videos AND x10 entries for our monthly giveaways!! NO PURCHASE NEEDED. Prizes are valued anywhere between $500-$2000!
Join here: / @diyhvacguy
IF YOU ARE IN NEED OF ONE ON ONE GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a low price of $400, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: / diy_hvac_guy
Tiktok: www.tiktok.com...
Facebook: / selfmadehvac
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.

Пікірлер: 129
@7x779
@7x779 Ай бұрын
I have used those A1 and A2 to screw saddle valves for decades, and occasionally gone back even years later to follow up on them and I don't recall one of them ever leaking. However, local suppliers here shifted to another brand with three screws and defeating coming off at it add an angle, the name is called bullet in an orange box I forgot the brand but I have had those leaked and in some installations they won't fit well. The one shown in this video are the best ones to get I would avoid others
@billiamc1969
@billiamc1969 Ай бұрын
This is the BEST ac channel on KZbin...I have learned how to service all my units at home saving 1000s
@lindabullard1596
@lindabullard1596 Ай бұрын
Yes, I have had such bad experiences from the AC company I bought my complete system from. Now I check with your videos and take care of my system myself. Thank you!!
@Harry1s
@Harry1s Ай бұрын
I've been an AC tech for 35 years - I've never seen a bullet valve that did not leak. I highly recommend to never leave them installed. If you think the circuit is low I recommend: 1) remove the remaining freon. 2) find and repair the leak. 3) leak test. 4) add factory recommended charge. 5) test operations. One other thing I've found a lot of people that work on window units don't know is that a lot of them have condenser water slingers = a plastic scoop on the cond fan that slings the water from the evaporator on to the cond coil. This helps keep the cond/high pressure down. If this is not operating properly the unit will not cool properly.
@synowiecj
@synowiecj Ай бұрын
You are completely correct. Bullet valves are temporary. And refrigerant in these units is measured in ounces, over charged is good either way
@BradBennet-md4tv
@BradBennet-md4tv Ай бұрын
Your right. But all that your saying is not worth doing on a window unit. A cheap charge is a good go to before tossing it
@Red-Raider
@Red-Raider 23 күн бұрын
First off a new a/c unit is $200-$300. For a homeowner to do this will cost the charging adapter, the freon and the valve. Your close to $200 right there. What have you saved? You still need to uninstall, and reinstall. You could save time, effort and headache (if the valve fails over time) by just replacing it! If you already have all the equipment, then try it, otherwise not worth it imho
@JetSettingBotanist
@JetSettingBotanist 13 күн бұрын
So I got a fairly new (2019) GE window unit for free on the curb. I don’t have brazing skills, so I was thinking about adding a bullet valve to add refrigerant, and UV dye so I can find a leak. What are your thoughts on repairing a leak with something like JB Weld? I wouldn’t be selling the AC so I’m ok with a little bit of risk, remember, the unit was free
@jalixvarietytv7849
@jalixvarietytv7849 11 күн бұрын
I agree with you. I also do the same as a technician.
@illiniwood
@illiniwood Ай бұрын
I think I'm going to learn to braze. I'm starting to believe it's a skill that's worth its weight in gold.
@mikafoxx2717
@mikafoxx2717 Ай бұрын
Silver, actually.
@grundyb
@grundyb Ай бұрын
Neat! I have the exact same gauge set as you. I don’t do HVAC work every day so this year I needed a little Freon and it worked perfectly. My condenser coil was so dirty that maybe 1/3 of the air could pass over the coils. I added Freon until I was about 38 degrees F. I added a tap years ago and added Freon to my mother in law’s refrigerator but the compressor was just not able to keep up and we needed to replace it. Refrigerators are easy to know when they aren’t working properly when the ice cubes can’t be made.
@TheRealRenn
@TheRealRenn Ай бұрын
You find the coolest products. Thank you for sharing.
@jameswest3890
@jameswest3890 Ай бұрын
Always great information Thank you. So many HVAC guys think there brain surgeons. I got a 608 just to work on my own equipment. Any half wit can pass the 608 test.
@Notdave29
@Notdave29 Ай бұрын
lol just don’t forget that the 608 test has nothing to do with being an HVAC tech.
@stevendevilliers471
@stevendevilliers471 Ай бұрын
Thank you. All your explanations are brilliant
@AverageJoesracingteam
@AverageJoesracingteam Ай бұрын
I have learned so much from this channel. Thanks for sharing your knowledge
@jamesszalla4274
@jamesszalla4274 6 күн бұрын
I’m a retired HVAC technician. You don’t change to above 32 on the temperature scale. You use superheat or subcool to change. The way you’re doing it, you can end up being overcharged or undercharged.
@7x779
@7x779 Ай бұрын
Have you ever checked your infrared thermometer against a real physical thermometer? I have three different ones and I pretty much gave up on using them professionally because they're so inaccurate and inconsistent. And when you're on a job with multiple people waiting, some of them in emergency situations, you don't have time for screw-ups and errors and confusion when you point the thing at something and it reads one thing and then you point it again and it reads differently. You need accurate readings. I get it though, all of us are lazy and would much rather point something in a register then get up and sometimes need a ladder to stick an actual thermometer in there but at least you know you're getting accurate reading Also a lot of people don't even understand that the infrared does not read the pinpoint that the laser is pointing to, but rather it's an ever-expanding funnel shape that measures a bigger and bigger Circle the farther the object is a way that you're measuring That should be taught to your viewers as well
@7x779
@7x779 Ай бұрын
Also, a very important piece of information missing, was that the temperature of the intake air to the evaporator coil was not measured in either before or after. I get it, it did get colder after adding freon of course But for the sake of accuracy, the most important thing is how much the temperature drop or split changed, since we don't know if the intake air temperature changed during this comparison. I just charged very expensive portable Runway air conditioner that keeps an emergency helicopter cool when sitting outside in 118° and blazing sun I had to charge it in actual operating conditions, so I brought it outside the hanger hooked everything up put my thermometers everywhere and started charging, and one of the staff members just opened a regular door several feet away from where I was working and I noticed it through all the readings off. I wondered why my ambient dropped 10°, if I went by my emotions and subjective feeling, it still felt hot outside and I could have ignored it which would have made me ignorant of the facts and what was happening. Just buy the guy opening the door it let enough cool air out of the hanger into the outdoors where I was working, that some of it was getting sucked into the condenser, so I would not have been charging it in actual conditions. Then I could have left and they bring it out to the helicopter and it goes off on high head. I understand this is not a concern when you're making casual videos for KZbin, but when you're actually out there on the line in the most extreme conditions and circumstances were people absolutely depend on you, you can't afford to be as casual and lackadaisical with your instruments and measuring methods
@frankdeleon9293
@frankdeleon9293 6 күн бұрын
Pretty good and informative. Most techs I have asked about it say to replace the unit.
@thatguy3468
@thatguy3468 Ай бұрын
Can use some help advice. My house has 3 4 ton central systems. All except one put out about 54 degree air, the one I’ve been concerned about only puts out at best 68 degree air. The condenser is clean, the refrigerant pressure is where it needs to be. The refrigerant I believe is 410a. The system in question cannot keep up when outside temperatures go above 95. Needless to say it’s been costing a fortune to keep the rooms on that system cool.
@qinlingzhou8815
@qinlingzhou8815 17 күн бұрын
R410A is very expensive. This method can be used to fix dehumidifier too if using R130A. :)
@Bowhunters6go8xz6x
@Bowhunters6go8xz6x Ай бұрын
Awesome video for servicing window AC units, you could see the frost was gone from the tubing after you got done. Also its a good idea to wear safety glasses when doing this or any work around freon, I know a guy that is blinded in one eye today as he serviced his own AC many years ago and some freon under pressure sprayed into his face and hit him in one eye.
@katisugarbaker7349
@katisugarbaker7349 Ай бұрын
To figure out the size of the line tap valve, you could also use that math you said you never needed in adulthood and just measure the line circumference. Then divide by pi. Some calcs have a pi button, so you can get a more accurate number or you can just use 3:141592. I’m not a handyman, though, so I’d consider the thickness of the pipe itself, too. Hopefully the AC unit specs would tell you. But do they differ that much from unit to unit?
@RobtTa
@RobtTa Ай бұрын
By far one of the best videos I have seen in a long time, Thanks!!
@cesarvazquez4658
@cesarvazquez4658 6 күн бұрын
Excellent video. Thank you 👍🏻
@jazzfreek54
@jazzfreek54 Ай бұрын
Perfect timing! Same operation with a dehumidifier I assume. Your info is amazing! Thank you... again!
@superspeeder
@superspeeder Ай бұрын
Could you do a deep dive video on how to read gauges? I’m sure many would appreciate it!!!
@TechnoAlliance1
@TechnoAlliance1 Ай бұрын
Curved brim finally 👍 Just playing. Love the channel man.
@brandog1734
@brandog1734 27 күн бұрын
I prefer to braze them on.
@scoobtoober2975
@scoobtoober2975 Ай бұрын
We'd love your thoughts on the newer heatpump window units. Midea who makes the aciq stuff. $400 for heating and cooling. heat that is way more efficient than electric space heater. tech ingredients here on youtube did a demo. but that was with an old unit. He said he's going to provide some improvements too, soon. Love you both. my aciq 2 ton inverter is sweet, even with colorado 100 deg day right now
@MrAcacio
@MrAcacio Ай бұрын
This is a great video. Thank you so much for teaching. I would like to suggest making a video on how to soldering Cooper ac pipes. May God bless you. 1000 Thanks
@MrHVACguy71
@MrHVACguy71 Ай бұрын
Did the wall a/c come from the factory low on refrigerant or is there a leak somewhere? I know once a piercing valve is installed they can seep at that location over time
@izb1678
@izb1678 Ай бұрын
This guy doesn’t seem to totally understand the consequences of some of the things he does
@jkmarshall3553
@jkmarshall3553 Ай бұрын
Then just add a bit more in two years...otherwise you need to trash that unit and buy another.
@borshardsd
@borshardsd Ай бұрын
Oh yeah lol piercing valves are for temporary use. Hilarious. I remember one of our guys videos [mostly this guy is 100%] where he had the general public vacuum out there condensate lines but never told them to prime the trap after, negating the point of the trap. But what do I know =D
@D2O2
@D2O2 Ай бұрын
Yes, everytime I have used a piercing valve it because the definite leak point, if not immediately, it did begin to leak shortly. I belive the vibration of the lines causes them to loosen and leak.
@skasev
@skasev Ай бұрын
Stop asking questions and top her up dude
@23x31
@23x31 Ай бұрын
These piercing valves do work although are hit and miss with leaking. They're used quite often on refrigerators that are low on gas.
@ChavezDIY
@ChavezDIY 18 күн бұрын
That was awesome. I didn't know this was possible. Would adding some nylog to the saddle valve help it seal better?
@terrillfloyd
@terrillfloyd 14 күн бұрын
Very good video I have about 8 window units that aren't cooling.I just took them out and buy another one now i'm not confix them
@1951Roy
@1951Roy Ай бұрын
Can you make a video on what an A/C company does when they come out to the house for yearly maintenance check. Thanks for sharing.
@kylelaw7210
@kylelaw7210 Ай бұрын
What gauges are vacuum pump would you recommend for a DIY person that wants to be able to install car (134a) and home AC (410A)? I don’t want the cheapest junk possible but also wouldn’t need top of the line equipment.
@9to5techs
@9to5techs Ай бұрын
I am in a mobile home and was wondering if you could help. Backstory: The unit started to freeze up at 64F inside house, thermostat set for 60F, 85 outside (i like it 🥶 ❄️ at night). I was using standard 3m merv 5 pleated filters on the A-coil( but tech said the evaporator coil was getting the cardboard/filter pleats that the filters are made of wet makeing more restrictoed air and to use those metal mesh A-coil filters 16 x 25) And merv 1 on return door(20in x 30in)= merv 6 Total. Those metal mesh A-coil filters are not that good at catching dust is their any other filters I could use on the A-coil evaporator without getting the paper pleated filters wet. The company that installed the unit put a R-410A 5 ton A-coil evaporator with a 3.5 piston in A-coil then put a 3.5 ton condenser outside. The air intake is a 20 in x 30 in with blower (4 speed up to 4 ton HP/AC, 2.9 FLA, 1/3 horse power@ high speed 1460
@denniszhaunerchyk6191
@denniszhaunerchyk6191 Ай бұрын
Nice video. Thank you for the review!
@s2sailingfree
@s2sailingfree Ай бұрын
Love your content, thank you for sharing. Could you please make a video performing the same service on an RV roof top AC unit. These units are notoriously expensive and it’s almost impossible to find anyone to service or recharge them. Additionally is there a sealant that can be safely added to repair small leaks? Thank you 🙏🏼
@user-rk1bf4eh2p
@user-rk1bf4eh2p 29 күн бұрын
Arizona used swamp coolers they work great if it didn't rain, we used to get the afternoon thunderstorms in monsoon season and then the sun would come out and they're worthless than
@user-rk1bf4eh2p
@user-rk1bf4eh2p 29 күн бұрын
That's really cool no soldering, cuz I suck
@tyronehowell3909
@tyronehowell3909 21 күн бұрын
can you add a small can 134a from auto zone
@jscott5042
@jscott5042 Ай бұрын
Great video. Thanks!
@rollandjoeseph
@rollandjoeseph Ай бұрын
Great tip if you have an EPA certificate i guess?
@natersalad889
@natersalad889 Ай бұрын
Quick online test and you can have one too....
@boblevey
@boblevey 29 күн бұрын
Nice video! Thanks !!!
@albundy3696
@albundy3696 6 күн бұрын
piercing valve may install to check out if there any Gas Left in the Unit , if some you can use that valve to remove how much then when gas out you can install permanent valve , unit what I seen in video already have valve on same pipe , why install second One ?
@jkmarshall3553
@jkmarshall3553 Ай бұрын
Great stuff! Thanks!
@lunacyworks
@lunacyworks 5 күн бұрын
can you post the actual link to valve you used in the video, the listed valves on amazon listed are not the same.
@salvadorcastillo1539
@salvadorcastillo1539 Ай бұрын
Thank a lot of for the video very good and helpful information......
@MrInkotime
@MrInkotime Ай бұрын
To install the saddle valve, don't you lose the refrigerant inside. How will you recover the refrigerant before?
@GhostReaper2043
@GhostReaper2043 Ай бұрын
you wont loose the refrigerant until you screw in the cap all the way in then it will pierce the line.
@MrInkotime
@MrInkotime Ай бұрын
@@GhostReaper2043 I meant the other valve that was brazed.
@illiniwood
@illiniwood Ай бұрын
I'm no HVAC guy, but I'd first install the piercing valve, recover the refrigerant, Remove the piercing valve, then braze on the other saddle valve in its place. Like I said, I'm no HVAC guy, but that's what I'd do. Please correct me if I'm wrong. We're all here to learn.
@ChavezDIY
@ChavezDIY 18 күн бұрын
Yes, if you want to braze on the saddle valve you will need to remove the refrigerant. HVAC techs have the equipment to recover the refrigerant so it doesn't get released into the atmosphere.
@rdlockrey
@rdlockrey Ай бұрын
awesome video, thank you so much!...
@fishlanding2
@fishlanding2 Ай бұрын
what do you think about the aluminum framed reusable electrostatic filters ?
@Dicofol1
@Dicofol1 21 күн бұрын
What is your opinion of the PRO-FIT Quick Connect Fittings from Rectorseal? Looks like a Sharkbite version for HVAC, looks safer to use with R290.
@jdthewelder8308
@jdthewelder8308 Ай бұрын
Great vid but what normal person has all that gear. Is there a diy kit like there is for auto ac jobs?
@northernliving2387
@northernliving2387 14 күн бұрын
How much freon dose a window A/C unit hold
@jimhoward1655
@jimhoward1655 Ай бұрын
Did i miss the ambient air temperature??
@american_patriot6218
@american_patriot6218 16 күн бұрын
I have a 4-year-old system, and the service tech said there is a leak in the coil. He said I will have to replace the coil, and the R410A would be $700, and the labor would be almost $3000. Is this normal? Can R410A with stop leak be used instead?
@erikyoung5139
@erikyoung5139 Ай бұрын
Is it possible to use staybright with these brazed ports?
@donc461
@donc461 Ай бұрын
Not sure why you installed your own saddle valve . The one below yours looks usable .What am I missing.?
@skyscraper37
@skyscraper37 Ай бұрын
I suppose this would work for a refrigerator too
@GhostReaper2043
@GhostReaper2043 Ай бұрын
yep
@johnverdin6600
@johnverdin6600 Ай бұрын
How to fix the heater on a two year old GE window unit
@TSGEnt
@TSGEnt Ай бұрын
Great tips! Great information! Thank you! Ok, the elephant in the room is; How does one get an EPA certificate?
@colinnwn
@colinnwn Ай бұрын
You can study and take the course online. He's got other videos about how to do it.
@bluejay713
@bluejay713 Ай бұрын
Hi i used skillcat to get mine he has a video on that.
@TSGEnt
@TSGEnt Ай бұрын
@@bluejay713 Thank you.
@TSGEnt
@TSGEnt Ай бұрын
@@colinnwn Great. Thank you.
@user-rk1bf4eh2p
@user-rk1bf4eh2p 29 күн бұрын
What happens when you don't have the ports to add the stuff
@blackout7615
@blackout7615 Ай бұрын
If im getting 35 to 40 degree air exiting my mini split and air entering is 70-75. Is that cold enough?
@christhinksit
@christhinksit Ай бұрын
First Channel I have ever wanted to join and even after watching a video on it still cant find the join button.
@phoneblaster
@phoneblaster Ай бұрын
...if I can ask a question please. You turned the freon cylinder upside down. If you can explain why it will be helpful. I am new to all this. Thanks
@diyhvacguy
@diyhvacguy Ай бұрын
So that you get liquid refrigerant
@phoneblaster
@phoneblaster Ай бұрын
@@diyhvacguy ...then you would only fill the side that is 'liquid' ? Is this correct. Thanks
@donc461
@donc461 Ай бұрын
410 is a mixture of two gases, if your only take the vapor off the top of the liquid you will not get the proper ratio of the two gases.So you invert the tank to get liquid and then add it slowly to avoid slugging the compresor with liquid.
@Time-Trvlr
@Time-Trvlr Ай бұрын
Would you benefit cleaning the line before installing the saddle unit?
@GhostReaper2043
@GhostReaper2043 Ай бұрын
to get a good seal I'd would think so but I dont think it would matter though
@TheDopalgangr
@TheDopalgangr Ай бұрын
Yes you would and he fails to mention that although if you watch the video closely the line magically goes from dirty to clean when he’s installing it so I guess he forgot that step then went back and did it during an edit.
@davidyummus6259
@davidyummus6259 Ай бұрын
I have an old Chrysler Wall A/C unit, probably early 90's,... Hosed the rear coil out at the end of last summer, ran fine now will turn on but won't make cool air. What did I do wrong ? lol.
@annettesurfer
@annettesurfer Ай бұрын
Reminds me of the time I hosed out a couple A/C window units and it wasn’t long before I had to replace the fan bearings. Easy and cheap but I learned not to do that again.
@googacct
@googacct Ай бұрын
A few years ago I was given a window AC unit that had lost its charge. I tried using one of those piercing valves and instead of piercing the copper line, it crushed it. I am not sure why that happened. I did not have any time to mess with it beyond that, so the AC unit eventually ended on the curb for big trash pickup day.
@MrNorthstar50
@MrNorthstar50 Ай бұрын
I have never used a piercing valve on AC, but I have have replaced many of the piercing valves that are leaking when they were used on plumbing. The rubber seals deteriorate in time or they have crushed the copper like your has. I would never use one on an AC .
@borshardsd
@borshardsd Ай бұрын
​@@MrNorthstar50if we use them in the field it's temporary. I agree with you fam
@MrNorthstar50
@MrNorthstar50 Ай бұрын
@@borshardsd I knew you were just doing it for a demonstration, you always try to do things the right way. I just thought some would think could be a permanent fix, I always like watching your videos.
@Dave-nm3xc
@Dave-nm3xc Ай бұрын
You are awesome.
@Kevin-mm6xm
@Kevin-mm6xm Ай бұрын
Surprisingly most of what he said was correct. The problem is finding and repairing the leak which most probably is in the condenser or evaporator coil. The unit was fixed once already as can be seen by the brazed in Schrader valve (brass cap). Those saddle valves are known to leak over time also. For a DIY with no experience in HVAC, by the time you get R410a, manifold gauge, valves etc, just to have it leak again, you are way better off just buying a new window unit then constantly charging at $100.00 or more a pop each time it leaks out.
@BillyBobDingledorf
@BillyBobDingledorf Ай бұрын
A two year old AC unit is already low on coolant? That's the real issue.
@joeearley3351
@joeearley3351 10 күн бұрын
Why does it leak? If it was made right it shouldn't leak for 40 years.
@skasev
@skasev Ай бұрын
I added 6 pounds to mine and still don’t work
@Igotstaknowit
@Igotstaknowit Ай бұрын
Amazing it is legal to buy r-22 online for about $30/lb if you are unlicensed and state you will not use it yourself and only plan on selling it to someone who is licensed. Like who is going to send the r-22 police to your house? What should be illegal is the thousands of dollars companies charge for a refill.
@bluejay713
@bluejay713 Ай бұрын
Hi only if your Epa 608 certified its not cheap 30 pound jug cost $845 from ability refrigerants they sale a recharge kit that has 2 pounds for $153 you can use skillcat to take the epa 608 test thats it thats how i got mine.
@tellittotheworld857
@tellittotheworld857 Ай бұрын
Or just throw it out and get a new one.😮
@brucey5585
@brucey5585 Ай бұрын
It's pretty useless for non certified technician. Also, if you need to add refrigerant, then it must be leaking somewhere. I have a 20 year old window a/c and never needed refrigerant. It is cheaper to just buy a new window a/c.
@seangriffon6502
@seangriffon6502 Ай бұрын
Yep, and all ac units today use a midly flamable R 32 A refrigerant. They have been using this refrigerant since 2016 so this unit this guy is servicing has to be way older thsn 2 yrs old.
@xSuperManW3x
@xSuperManW3x Ай бұрын
This is all completely pointless LOL.... These units are DESIGNED TO FAIL after the 1st season/year When you buy a new a/c if it does not have a drain, drill a couple drain holes........ These aircons are made to pool water and then spray that on the coil, well it certainly increases the efficiency rating so they can sell them for a higher $$$.... but in reality this increased efficiently is almost meaningless in reality........ All this does is spray outside air and gunk and clog up the outside coil to the point that the ac fails because the outside coil is so clogged that air can no longer pass through it .......... well saving 25$ in a year sounds good..... until you realize that after a year you have to pay 500$ to replace you broken A/C......... BUT IN REALITY this a/c design builds up pools of stagnant water and gunk which it then sprays on the coil which then clogs up the outside coil and essentially makes the aircon blow up after a single years use... certainly having a few drains slightly decrease efficiently, but the gains outweigh the detriments...... With a few drains the water never builds up and becomes gunky, and this dirty sticky water is not sprayed onto the outside coil just to clog it up and make the a/c fail after a single season........................ I am honestly surprised soo many ppl defend the anti hole drillers here... LOL
@nonyaanon6801
@nonyaanon6801 Ай бұрын
Know it all video, damaging trade value type.
@kitchenenterprise3787
@kitchenenterprise3787 18 күн бұрын
👏👏👏👏🇺🇸😎
@Notdave29
@Notdave29 Ай бұрын
We just throw them away and buy a new one. If I have to work on it for an hour and buy a part then it’s cheaper to just replace it. Same for refrigerators. I only work on laboratory/medical or large commercial refrigerators. Anything smaller is almost never worth the time and money.
@worlddemize
@worlddemize Ай бұрын
what a dork .
@GeorgeWashingtonLaserMusket
@GeorgeWashingtonLaserMusket Ай бұрын
Uh I'm deeply concerned about this video. You're seriously advising people to use a tap that isn't soldered on there? That's going to cause more leaks... HVAC isn't something where pressure fit is viable, every connection should be soldered/welded. This is disappointing, that tap would be legitimate for once time use to extract gas if you then seal/cut and replace the damaged pipe that'd be fine. Is that even rated for use in the free world? It looks like something that wouldn't even be legal in China or India, remember just because you can buy it doesn't make it legal. Also in the USA you have to be licensed to do this. I didn't hear you say that as a legal disclaimer/warning.
@GhostReaper2043
@GhostReaper2043 Ай бұрын
Anyone could do this as long as you know what your doing and are using proper equipment. Plus if you read the video description notes you would find his disclaimer/warning next time read the video notes not that hard to find. Yes, he is a licened HVAC Contractor in the state of Utah. Copied from the video notes he stated.... "⚠ Disclaimer: This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information."
@skasev
@skasev Ай бұрын
Qualified maybe but not to teach
@silat13
@silat13 Ай бұрын
Are you saying he's wrong and what he said? If so could you write the correction in your reply?
@Watchyn_Yarwood
@Watchyn_Yarwood Ай бұрын
@@silat13 Better yet, document your certifications and experience to make such a statement. Everyone has a keyboard and can type anything they wish. Actions speak much louder than words.
@user-rk1bf4eh2p
@user-rk1bf4eh2p 29 күн бұрын
Dirt and dust
@therealdheel8177
@therealdheel8177 26 күн бұрын
Go ahead and put gauges on a unit without that EPA 608. Take pictures and send them to me. So, i can turn you in and make that money. An piercing valves are garbage. It is going to leak again in the future. Get a schrade valve with a copper stem. Burn a hole in the copper, and braze on the schrader valve
@izb1678
@izb1678 Ай бұрын
Why would you add another one just another point to leak from
@jkmarshall3553
@jkmarshall3553 Ай бұрын
Dude!
@mikemike4415
@mikemike4415 Ай бұрын
Because that's probably the only demo unit he had on hand. He stated someone else installed the 1st one. Had to install the saddle one to make the video.
@diyhvacguy
@diyhvacguy Ай бұрын
For demonstration purposes
@brandog1734
@brandog1734 27 күн бұрын
I prefer to braze them on.
How To Add Refrigerant To Air Conditioner
22:08
Word of Advice TV
Рет қаралды 1,8 МЛН
Clean Window AC the LAZY (but still effective) way!
7:48
Handyman Hertz
Рет қаралды 1,7 МЛН
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 27 МЛН
Вы чего бл….🤣🤣🙏🏽🙏🏽🙏🏽
00:18
а ты любишь париться?
00:41
KATYA KLON LIFE
Рет қаралды 3,4 МЛН
HVAC Contractors Hate Me For Sharing This Secret
10:21
The DIY HVAC Guy
Рет қаралды 899 М.
Soldering An HVAC Line Set Using Staybrite 8.  STRONGER THAN BRAZING!
29:04
How to add refrigerant to a refrigerator
10:02
Gabriel Handy Man Projects
Рет қаралды 25 М.
Can This Device Actually Lower Your Electric Bill By 30%??
11:37
The DIY HVAC Guy
Рет қаралды 2,4 МЛН
4 Air Conditioner SECRETS That HVAC Companies Don't Want You To Know About
12:20
3 PROVEN Methods To Getting Colder Air From HVAC Vents.
10:45
The DIY HVAC Guy
Рет қаралды 638 М.
Window Air Conditioner Not Cooling And The Most Common Fix
14:55
Word of Advice TV
Рет қаралды 1,9 МЛН
How To Add Refrigerant To Your Air Conditioner R410A & R22
10:15
The DIY HVAC Guy
Рет қаралды 743 М.
Charging R-410A Refrigerant Into An Air Conditioner Using Wireless Probes!
33:46
Are more STAGES on an air conditioner worth it??
10:28
Atlas AC
Рет қаралды 348 М.
This Dumbbell Is Impossible To Lift!
01:00
Stokes Twins
Рет қаралды 27 МЛН