How to test Daikin PCB for Communication Faults.

  Рет қаралды 5,498

Mitch Attwood

Mitch Attwood

Күн бұрын

Пікірлер: 30
@brewaz
@brewaz Ай бұрын
You are an inspiration, so many people will not share this type of information!
@maracservices
@maracservices Ай бұрын
@@brewaz thank you, I hope it helps!
@MitchellMIller-db7gk
@MitchellMIller-db7gk Ай бұрын
Hey Mitch, enjoying your video. Clearly explained and easy to understand with real world tests. Keep them up, well done.
@maracservices
@maracservices Ай бұрын
@@MitchellMIller-db7gk thanks 🙏🏻
@robalexander7348
@robalexander7348 7 ай бұрын
Explained well Mitch, so handy for the boys entering into the A/C game 👍
@HHK1090
@HHK1090 7 ай бұрын
Really liked this video! Very informative. Thank you Mitch!
@maracservices
@maracservices 7 ай бұрын
My pleasure!
@せとやん-d9l
@せとやん-d9l 7 ай бұрын
It's a very easy-to-understand explanation. There are so many types of multimeters. If there is a particularly recommended multimeter, I would like to see that video someday.
@craigladewig3158
@craigladewig3158 7 ай бұрын
Cant go wrong with a Fluke - Costly but well worth it, you could be risking your life using a cheap tester
@maracservices
@maracservices 7 ай бұрын
I recommend the fluke kit that’s designed for hvac. It comes with the multimeter you see in this video and another one that can measure amps. Cheers mate
@boldizsarnovak9037
@boldizsarnovak9037 7 ай бұрын
Really informative video! Thank you and keep up the good work!
@maracservices
@maracservices 7 ай бұрын
Glad you liked it!
@juanantoniog5875
@juanantoniog5875 7 ай бұрын
Gracias por compartir sus conocimientos
@mazayamazayanadira6862
@mazayamazayanadira6862 7 ай бұрын
Im 🙏from indonesia teknical mate, Good job mate❤😊
@maracservices
@maracservices 7 ай бұрын
Thanks mate
@jixia676
@jixia676 7 ай бұрын
Thanks Mitch, Do you know how to confirm if its the ourdoor PCB problen or indoor PCB problem?
@WorkOrderMania
@WorkOrderMania 4 ай бұрын
Hey Mitch, new subscriber here.⭐️🌟⭐️
@michaelburns5680
@michaelburns5680 7 ай бұрын
Not sure if you have one but the most valuable piece of hardware you can have for checking Daikin residential equipment is the Daikin Transmission Checker (I don’t even know if they sell it anymore). It hooks up to 1,2,3 terminals and it tells you all the indoor data such as sensors and requested capacity sent to the outdoor. On the outdoor side it tells you sensors, outdoor fan data, compressor hz etc. If it doesn’t pick up the indoor or outdoor on the transmission checker it generally sends you in the right direction to go checking.
@maracservices
@maracservices 7 ай бұрын
Interesting, I can’t say I’ve seen one of those. Sounds pretty handy!
@Optuss
@Optuss 7 ай бұрын
Thanks Mitch. What would you expect to see for the low/high readings with bad boards?
@mattgansky2179
@mattgansky2179 Ай бұрын
If the DC volts are not in the range, does that mean bad board or is there a fix ?
@maracservices
@maracservices Ай бұрын
@@mattgansky2179 that means bad board mate
@45KevinG45
@45KevinG45 27 күн бұрын
Hey, so if the dc voltage is above or below the 10-50vdc. What does that indicate?
@aus_aircon_ref_mech6671
@aus_aircon_ref_mech6671 6 ай бұрын
Hello Mitch Excellent video! I never knew the min-max function on my multimeter! Great information here. Does this mean that if you get zero for the high voltage then the outdoor board is bad? If you get zero for the lower voltage then the indoor PCB is bad? Or would you just change both?
@eliaskoch5604
@eliaskoch5604 7 ай бұрын
if there is 45 dc and 0dc then is it the indoor bord faulty and if it 10dc then 0dc is it the outdoor bord faulty ????
@boulmo9167
@boulmo9167 7 ай бұрын
It depend If that happen then you probably have to check indoor and outdoor board check the fuses it could be both board that’s bad but usually outdoor bad board are the common one
@ThomasMarchant-c1y
@ThomasMarchant-c1y 5 ай бұрын
Normally if the indoor fan runs on fan only mode. Usually the outdoor board is the bad one
@KINGDADDYBOB
@KINGDADDYBOB 5 ай бұрын
If you hold orange meter button while rotating center knob to on, the meter will not time off/out.
@aldoo5985
@aldoo5985 7 ай бұрын
Cognitive inf. Tnks
Daikin Air Conditioner NOT HEATING!
30:11
Mitch Attwood
Рет қаралды 5 М.
GIANT Gummy Worm #shorts
0:42
Mr DegrEE
Рет қаралды 152 МЛН
Who is More Stupid? #tiktok #sigmagirl #funny
0:27
CRAZY GREAPA
Рет қаралды 10 МЛН
Daikin / High-wall Split System Won’t Turn On
11:46
HVACR AUS
Рет қаралды 2,7 М.
Diagnosing Daikin E5 Error
15:50
Mitch Attwood
Рет қаралды 11 М.
The 3 Pillars of Daikin Service Checker Analysis
20:55
Roman Baugh
Рет қаралды 11 М.
How To Check ECM Motors - HVAC Training
11:07
HVAC Pioneer Controls
Рет қаралды 28 М.
Daikin U4 Troubleshooting
24:37
Christopher Brown
Рет қаралды 2,5 М.
Top 5 Things AC Companies Don't Want You To Know How To Do!
12:40
How To Home
Рет қаралды 2,4 МЛН
I CAN'T BELIEVE that this has happened AGAIN!
29:46
Mitch Attwood
Рет қаралды 7 М.
GIANT Gummy Worm #shorts
0:42
Mr DegrEE
Рет қаралды 152 МЛН