Central Air Conditioning A/C System is DEAD! Only the thermostat goes CLICK when you turn it on! How to Troubleshoot and Diagnose a bad contactor which burnt out the primary/secondary 24 volt transformer. Step by Step.
Let's Make The Trades Great Again & While Giving Back To The Community:
/ channel
www.pipes4free.org
Our mission is to provide free or low cost plumbing, heating & cooling services to those in our community who can't afford to hire a professional. Mikey Pipes Philanthropy, Inc. is a IRS registered 501(c)(3c) public charity incorporated in the State of New York.
Donate on Paypal: www.paypal.com...
What’s in your Veto? Here is mine:
Veto TP-XXL amzn.to/3zX10vg
Malco 5/16" & 1/4" 6" Driver tinyurl.com/Ma...
Milwaukee M12 Fuel 1/4" Impact Driver amzn.to/3I9yLfI
Milwaukee PVC cutter: amzn.to/3sbrdUc
Mini Waterproof Storage bin: amzn.to/3yfgsEv
Wiha Allen Keys: amzn.to/33ipGmb
HIKMICRO B20 amzn.to/33iGklx
Furnace Switch amzn.to/31X89PT
Milwaukee Light amzn.to/3I38Lmh
Wagos amzn.to/34QoiaU
Milwaukee Set amzn.to/33vnQOz
Torpedo Level amzn.to/3no1oOk
Crescent set amzn.to/3GtZeV8
Wiha 7 piece set amzn.to/3rkISaK
Milwaukee step bit amzn.to/3I395Bv
Flare wrench amzn.to/3noJZ8s
Ridgid 10” wrench amzn.to/3GvRnqa
Fluke non-contact tester amzn.to/31VQgAQ
Klein drivers amzn.to/3qoe21W
Knipex Wrenches amzn.to/3trzFjS
Klein 11-1 amzn.to/3tpsPLD
12” crescent amzn.to/3A0CZ6S
Gerber Gear Pocket Knife amzn.to/3foaW7I
Yellow Jacket Hand Ratchet amzn.to/3nrDgup
Need a website for your contracting business? Check out Footbridge Media for their amazing special on not only a website but SEO services for only $249/month! www.footbridge...
Tired of HouseCall Pro? Don't wanna be ripped off with ServiceTitan? Try ServicePal for free for 30 days! app.servicepal...
Check out my Uncensored channel: / mikeypipesuncensored
Oval raised silver stickers are from:
Armored Decal Company Inc.
35 Victoria St. E, Unit 9
Alliston, Ontario L9R 1T3
(p) 705-435-6665
(e) ken@armoreddecal.com
(Tell them Mikey Pipes sent you)
Please support this channel and Mikey Pipes and consider the following…
UPDATED: May 15, 2023
PIPE DOCTOR FLEX FIT HATS only $40 each shipped USPS! Or 2 for $70
Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
Donations Accepted:
PayPal: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Zelle: office@pipedoc.net
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes
C/O Pipe Doctor Home Services, Inc.
80 E Hawthorne Ave
Valley Stream, NY 11580

Пікірлер: 39
@scottvolage1752
@scottvolage1752 Жыл бұрын
Testing not guessing. Another fine job Mike. Make the trades great again.
@Theoldchum
@Theoldchum Жыл бұрын
Shunt, not stunt!
@Theoldchum
@Theoldchum Жыл бұрын
@@PipeDoctor No charge, LOL
@videoforgeeks
@videoforgeeks Жыл бұрын
I think "radio" killed the transformer side...radio killed the transformer side...lol
@videoforgeeks
@videoforgeeks Жыл бұрын
@@PipeDoctor kzbin.info/www/bejne/jWnVXqeOh7GUsNU
@videoforgeeks
@videoforgeeks Жыл бұрын
The "first" video ever played on MTV back in the day...I thought of it when you said what killed the transformer....Have a good one! 🙂
@eddiew.6485
@eddiew.6485 Жыл бұрын
The true meaning of “Diagnosis and Repair”!
@louisviciedo
@louisviciedo 2 ай бұрын
I just moved into a new home and want to instal an ecobee. I went to the transformer and only have 1 segmenet of 24v through the RED secondary, the GREEN secondary is grounded and doesnt have constant 24v. The GREEN wire is connected to my BLUE C wire. the result is that Im not getting constant power to my thermostat C wire. Is this a wiring problem?
@tckr4883
@tckr4883 Жыл бұрын
If that low voltage terminal block was dangling I’d say that was the issue….ten seconds later I was wrong. Nice job. Did a nice Bosch yesterday…BOVA-60…when you coming to Florida? I make my maintenance tech watch your videos for homework.
@Samlol23_drrich
@Samlol23_drrich Жыл бұрын
Good job. Fyi, a Shunt goes across without interruption. A stunt is what Evil Kinevil used to do. Not being a dick. I would want someone to tell me
@christopherchance4860
@christopherchance4860 Жыл бұрын
Bud Lights VP of marketing killed the transformer
@pitt1108
@pitt1108 Жыл бұрын
When did wago fix the fatal fault in their design. (Contact only on 2 points of wire)
@ijmj87beasmodemartin24
@ijmj87beasmodemartin24 3 ай бұрын
Thank you sr you save me $ time. I'm a home owner in New jersey here everything cost so much this guy came to my house saying yes to fix your problem we taking about 1,200$ I was like nope thank you 7/2/24
@caflatt7436
@caflatt7436 Жыл бұрын
I take it that the system had no fuse to protect transformer why not add one. Professional touch. For next guy, maybe you
@javajetson257
@javajetson257 2 ай бұрын
Ok. This dude is cool.
@eastcoast186
@eastcoast186 Жыл бұрын
WTF does:) this mean in English
@EugeneAtViaTyping
@EugeneAtViaTyping Ай бұрын
Nice episode, thank you!
@PipeDoctor
@PipeDoctor Ай бұрын
Thank you too!
@dburks1273
@dburks1273 Жыл бұрын
Bad contactor or shorted low voltage wire
@billycarr7446
@billycarr7446 4 ай бұрын
I am mechanically inclined and love to DIY everything. That said I am not HVAC savvy, til a few days ago when I turned on the AC for the 1st time of the seasom when it smoked something within a minute. Much research and a parts cannon later I have a much better grasp of a low voltage circuit. appx $200 in parts from Amazon later I am sitting in a cool dry house and I did it! These vids are awesome for us neophytes. My ex wife just spent $800 with a service tech getting hers back up. :-) Yeah, I know, I still have some anger issues. I won by $600. The problem ended up being son #1 was weed eating around the house a few days prior. He snagged a skinny lil wire at the condenser unit and it looked OK. 3 feet back under the wood box guard the 2 wires were deteriorated and touching each other. I ohmed across these 2 wires up at the contactor coil (wires not connected) and got an open so thought the wires were fine. Always visually inspect everything! Would have saved me the $200 but now I have some spare parts for next time and I got some not quite instant gratification. Service techs gotta make a living too but my nature is DIY and spend that money on toys.
@davidlampe4153
@davidlampe4153 Жыл бұрын
Nice video thank you but I’m not understanding how it works. I’m not understanding what the sequence is but I’m going to watch it a few times and maybe it will be clear.
@xlostf8x348
@xlostf8x348 Жыл бұрын
A 50Va Transformer? I honestly expected a 75Va out of a master plumber. Zone heads baby lol
@kat2641
@kat2641 Жыл бұрын
Lol you got to love them cheep disconnect boxes 😂😂😂 I was honestly thinking short in T stat wire or a dead short on the contractor to ground…. Great troubleshooting.!!! I always figured a great troubleshooter was worth more to me than a great installer.
@zeljkoprezimee4439
@zeljkoprezimee4439 Жыл бұрын
I would put breaker in 24v line to protect transformer if it isnt there..
@mantorras7752
@mantorras7752 Жыл бұрын
Mikey... how do you feel about the Bryant brand?
@mikehouser5430
@mikehouser5430 Жыл бұрын
1st
@flastname560
@flastname560 Жыл бұрын
How do you like those Wagu connectors
@tedlahm5740
@tedlahm5740 Жыл бұрын
Very enjoyable. Very informative.
@zacharypalczynski8450
@zacharypalczynski8450 Жыл бұрын
My guy , Mikey fuxkn pipes !!
@gordonkaufert5013
@gordonkaufert5013 Жыл бұрын
Fine job Mike 👍
@chuckquinn8026
@chuckquinn8026 Жыл бұрын
Love my new Wago butt connectors! What is the advantage of single pole contactor vs double pole?
@chuckquinn8026
@chuckquinn8026 Жыл бұрын
@@PipeDoctor is there a reason you would want/need that?
@chuckquinn8026
@chuckquinn8026 Жыл бұрын
@@PipeDoctor thanks Mikey. Just never heard it explained before
@Knoxxy91
@Knoxxy91 Жыл бұрын
Awesome video!
@scottmaz4063
@scottmaz4063 Жыл бұрын
Good repair
@danielrandolph9170
@danielrandolph9170 Жыл бұрын
Cool ! 👍
@cobrajoe2001
@cobrajoe2001 7 ай бұрын
Thank you so much the info
@PipeDoctor
@PipeDoctor 7 ай бұрын
You are so welcome!
AC Won't Start - How To Troubleshoot & Replace a Contactor - 1 Pole vs 2 Pole
15:46
The Joker wanted to stand at the front, but unexpectedly was beaten up by Officer Rabbit
00:12
SHAPALAQ 6 серия / 3 часть #aminkavitaminka #aminak #aminokka #расулшоу
00:59
Аминка Витаминка
Рет қаралды 1,9 МЛН
JFK Airport Hotel Not Cooling from Daikin Ducted Mini Split System
12:16
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 13 М.
AC Contactor Troubleshooting and Replacement
6:50
Apartment Maintenance Pro
Рет қаралды 39 М.
Is the relay REALLY bad? | Understanding HVAC Electrical Concepts
24:59
How to find a low voltage short HVAC Basics @EngineeringMindset
9:12
AC Not Working... Contactor Not Getting VOLTAGE
10:02
Sam
Рет қаралды 305 М.
How to Complete a Successful Central AC with Furnace Preventative Maintenance Service Call
14:55
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 11 М.
Será que o vidro elétrico vai cortar a língua ?!😱 #shorts #challenge 
0:18
Was the little angel trafficked?#Short #Officer Rabbit #angel
0:50
兔子警官
Рет қаралды 6 МЛН
헤어지면 세금 100배인 여친 화장 💗 #makeuptutorial #길화장 #길화걸
1:00
مين بيعمل أكل اطيب  ماما 🧕 أو بابا🧔#shorts #hasanandnour
0:27
NourSan Family | جودي و كايا
Рет қаралды 5 МЛН