You are a smart electrician and an even better teacher, Benjamin. Your videos have taught me more than even coworkers have. I admire your willingness to share your knowledge and again, the step by step clear way with which you do it.
@emperorfancypants25122 жыл бұрын
In my country its against code to bring 2 circuits in the same box due to safety reasons
@DriverDude1005 жыл бұрын
When my house was wired years ago, the electricians connected together the "hots" from two separate circuits in one upstairs switch box. Whenever both switches were turned on, one of the two breakers feeding the switch box would trip. The electricians couldn't figure out their mistake, so they changed one breaker location effectively powering the two breakers by the same phase in the main panel. This of course only compounded the problem since both breakers had to be turned off to de-power the combined circuits. It took me a little while to figure out where they had combined the "hots". Your work in this video is excellent.
@BenjaminSahlstrom5 жыл бұрын
That's such a bummer. Its amazing how much headache such a simple mistake can cause. That is also a good reason to keep multiple circuits out of a box. If at all possible I avoid having multiple circuits in a box but sometimes it is somewhat unavoidable. Thanks for sharing your experience! Not all electricians do work of equal quality that's for sure.
@aaron745 жыл бұрын
Great story. No electrician worth his/her salt should ever have made such an error.
@jasonhill22752 жыл бұрын
My dude you've helped me so much. I'm rebuilding my 120 yr old family farmhouse by myself. It all makes perfect sense being a builder with minimal electrical experience things are going smoothly with rough wire for me from your videos. I like that you keep closest attention to detail as you can with out overkill. Thanks again
@tattoo3294133 жыл бұрын
This video was a huge help and I can't stress it enough. I do mostly trim, tiles, doors, sheetrock, windows etc. A lady I work for couldn't figure out why the three gang box wasn't working that had three 3-ways in it. So I opened it up and nothing was hooked up. I couldn't figure out why I kept tripping the fuse and now I know why it's because there's two circuits and I kept putting all the neutrals together. Now I know what I was doing wrong because I got confused with the four 14/3 and three 12/2 and 2 separate circuits. I will definitely be watching a lot more of your videos
@karenbridenbaugh19474 жыл бұрын
One of the better teachers on KZbin. Thank you!
@GMCCanyon042 жыл бұрын
This video has enlightened me on a recent upgrade in my house. I’m a mechanically inclined DIY-er. And I just couldn’t figure out for the life of me what the previous owners did in a switch box. They didn’t label anything so a simple addition of a smart switch took me a few hours between looking up you tube videos and just sitting back staring at it trying to figure it out in my head. This video came a little late as I already figured it out. Buttt I do have a full on renovation of an addition that was added in 2000. I will be gutting it to the studs and doing all new electrical all the way to the panel. It will be done the right way as I will be having it inspected by the local inspector. This video has given me a lot of ideas as to when I do go to do this renovation. Thanks and keep up the good work!
@rojadoja5 жыл бұрын
Love the video. Only thing I would add is that when you make your loop for the terminals on the switch, let viewers know that it matters which direction the loop faces. You’ve been doing it so long you probably just take it for granted. Keep up the good work!
@BenjaminSahlstrom5 жыл бұрын
Totally! I've said it so many times in other videos that I totally spaced it here. So funny how your muscle memory takes over and you don't even think about it. Thanks for pointing that out!
@TomCee533 жыл бұрын
And you still didn’t say. The wire curl clockwise to pull it in as you tighten. If you go counter-clockwise it can actually back the wire off the screw.
@BearStar14 жыл бұрын
I'm a Licensed Journeyman Electrician with over 52 years in the trade, mainly Residential and Light Commercial, and I have never '' twisted the wires together '' with pliers prior to installing wire nuts or wingtips wire connectors and never had any problems or complaints from any of my customers or clients ! I've been doing it the way as I was taught in the State Vocational 4 yr. Apprenticeship Trade School !
@travispfeifer19794 жыл бұрын
Let the wire nut do what it was designed to do. 😉
@graken224 жыл бұрын
? Explain why not to wire twist before the nutz???
@BearStar14 жыл бұрын
@@graken22 ; not required as the Wingtip Wire Splice connector will do that if the ends of the wires being spliced are even. The inner metal screw shell inside the Wingtip Wire connector will grab and twist the wires for you !
@sowrong16114 жыл бұрын
Cool story boomer
@anthonyesposito72 жыл бұрын
@@graken22 Have you not ever put a wire nut on wires without pre twisting them? Try it and then unscrew the wire nut carefully and you will see that the connection is identical to a pre twisted one. Usually I only pre twist if I have more then 3 wires because in that case you have to give them a little taper to fit in the nut and twisting helps with that.
@andrewallen87643 жыл бұрын
Look aIm not the only person who said you're a good teacher Jaja. I too appreciate your willingness to share your knowledge and teach in a step-by-step approach.... Most Respectfully Andrew Allen
@tompeters42345 жыл бұрын
Good video. When you twisted the wire to be attached to the strip, I did not hear you mention to twist them in the direction the screw turns when tightening them so the wire gets 'pulled' in under the screw rather than backwards and pushing the wire out. They way you showed in the video was correct. It makes life easier if you have not done them before.
@BenjaminSahlstrom5 жыл бұрын
You're absolutely right! I totally forgot to point that out specifically. I'll definitely have to point that out better next time.
@luckyhiker34342 жыл бұрын
Real good instructional video. I would love if you would demonstrate a box fill calculation for this particular box so we can see how full it actually is! Super job!
@tonychan45264 жыл бұрын
I've never seen such conscientious labelling in a box! so good
@seephor5 жыл бұрын
Try that box with 12Awg and you will build muscles in places you thought muscles couldn't be built.
@BenjaminSahlstrom5 жыл бұрын
Haha for sure! My fingers start to hurt in short order when twisting wire nuts on 12awg wire. Wagos help reduce that of course.
@aaron745 жыл бұрын
@@BenjaminSahlstrom I sometimes use Channellocks to wirenut a bunch of 12s!
@mr.3phase2285 жыл бұрын
Ha ha child's play, try working on an old house with 20a circuits... 10 gauge aluminum wire + pigtails for cu only divices and noalox
@aaron745 жыл бұрын
@@mr.3phase228 Aw yuck, I've never seen aluminum wiring in homes. My 1890 house even has copper (knob & tube). That stuff is kind of obnoxious.
@BearStar15 жыл бұрын
@@aaron74 ' I rewired a older single wide Mobil Home back in '85 that had all AL Wiring . Tore out all of the AL wiring , installed a new 200 Amp Main on a New Service Pole and then installd the service feeder underground in Schedule 80 PVC to the new Main Panel which I relocated to the the Hallway between the Liv area and the Master Bedroom and Rewired with all CU !
@bigdaddya7353 жыл бұрын
I just wanted to say thanks for your videos....because of them I am going to get a raise alot sooner.....lol 😆 👍
@johnhickman15343 жыл бұрын
Well done. Very informative and to the point. Video recording was great. So many vids have way too much unnecessary dialog (often personal) and shakey video. I will use your channel for references. Good job!
@Trainman04014 жыл бұрын
Just curious if you sized the box for the amount of conductors and devices? It appears the volume of the box is inadequate from what I can see. Thanks.
@Eddy635 жыл бұрын
Your right about the Wago lever nuts and the Ideal pushins ... It makes life a lot easier ... Good vid Benji ...
@BenjaminSahlstrom5 жыл бұрын
I hadn't use Wagos until recently and man are they nice! I have a video coming up very soon comparing the two. I think that "wire nuts" have a very limited future in the work I'll be doing!
@aaron745 жыл бұрын
@@BenjaminSahlstrom Wago splice devices are very cool, they've been used in European countries for decades (on their standard 230V circuits no less). Wago is a German brand and actually pronounced "vah-go", but everyone in English-speaking countries say way-go. In the most extreme technical sense, they are a higher-resistance splice than a well-twisted wirenut splice just due to the bridged metal-to-metal spring contact, but there is probably only micro-ohms of difference so it doesn't matter--it's more of an academic rather than practical debate. If you get them, be sure they're the Wago brand and not a Chinese knock-off that you can get on like aliexpress or whatever. They must be UL listed, which Wago is. They are absolutely amazing for doing splices of LOTS of wires together!
@VegasBonBon4 жыл бұрын
You are great , Thank you so much for the great videos I learned a lot from this. I know nothing about electric wiring and I was able to wired Broan 9093wh which is complicated for me. Took me hours trying figured it out how to wires but after watching your video making me understand more about electric wiring and it took me 5 min to get it done. Thanks again🙏🏼🙏🏼🙏🏼. By the way what city do you live in I am living in Las Vegas 😀
@la5150hi-lophoto4 жыл бұрын
My father was an electrician but a terrible teacher and one time I shorted a wire....thanks for explaining so I can understand.
@heroknaderi3 жыл бұрын
This video was very helpful I appreciate your time and enjoyed watching.😁😎👍 and I’m curious are you going to put drywall around it
@travispfeifer19794 жыл бұрын
Ideal wire twisting drill attachment helps on large groups of 12-2!
@Dutch2go Жыл бұрын
Great video. Question for you Benjamin - how can you determine if wires coming into a box all belong to one circuit or to two circuits? I’m trying to determine if a gangbox in my bathroom has wiring belonging to one or two circuits. Aside from the wiring for the bathroom there is a cable going from the box to a first hallway switch which in turn has a cable going to a second switch in that hallway at the entrance to the kitchen. Is that cable part of one bathroom circuit or part of a different circuit? I need to know if I can connect the neutral and hot wires of that cable with the neutrals/hots of the bathroom wiring.
@sylvesterstewart8684 жыл бұрын
How I was taught: Use the razor on the last few inches of the romex. Skin it up into the box. Use diagonal cutters to cleanly cut sheathing leaving a 1/2 inch. A sound mechanical connection is a sound electrical connection. Wire twisting (Linesman pliers) creates a mechanical connection, wire nuts insulate those connections. Create a tight braid of the grounds. (Not so tight you pull on the other wires.) In "short" USE YOUR KLEINS MAN!
@dhillman75223 жыл бұрын
Excellent help, I have to wire a four gang with three circuts tomorrow.
@Horsecare64310 ай бұрын
Benjamin, the can you explain , you mentioned tge power is coming in , and going out where is it going to after that ?
@jordansmith8914 жыл бұрын
3:34. I really appreciate your videos so far, they've been very helpful. Just wondering why you have 7 sets of wires going into this box and also why you had to pigtail the ground wires.
@sirnordeng4303 жыл бұрын
The Tan wire nuts he is using technically only accommodate 5 wires,
@jon_craftingo.o46863 жыл бұрын
All the grounds need to be connected to each other, but their are limitations to how many grounds can go in a wire nut (5 in his case) and how many grounds can go into a switch (which is only 1). Pig tails make all of this possible.
@focused00023 жыл бұрын
Always impressed and left more knowledgeable...thank you
@candicejames38005 жыл бұрын
I find this video to be really helpful. You are a great teacher. Thank you
@poolsdoc91784 жыл бұрын
I don’t like to put more than 6 #14/2 in those shallows 3gang boxes, good video
@aaron745 жыл бұрын
I generally prefer steel boxes in general for their quality and strength, and the #6-32 tapped holes for the mounting screws of devices. But where steel boxes REALLY shine is with multi-gang installations. NEC permits you to use self-grounding devices with steel boxes if the box is grounded. Many of the low cost (often called residential-grade) devices are not marketed as self-grounding ONLY because there is little piece of plastic that prevents the mounting screw of the device to fall out of its yoke. BUT if you remove this piece of plastic and make sure the device makes solid metal-to-metal surface contact when you tighten it in place, then the device will be grounded if the steel box is grounded, and it won't need another pigtail ground to its ground screw. This is a huge benefit with 3-gang or more boxes, it really cuts down on wire fill congestion.
@youvegottoseethis56155 жыл бұрын
@ Aaron Kassel Thanks for the input. As we speak I am making a decision about plastic vs. steel 3 gangs I'm installing. Going steel.
@aaron745 жыл бұрын
@@youvegottoseethis5615 Glad to help. A three gang welded steel box can be hard to find, so you may need to purchase three single gang device boxes and assemble them. If I were a welder, I'd weld them together so there is no chance they can come apart.
@Nick-bh1fy5 жыл бұрын
Ugadda Seedis not sure where you live but in Canada the CEC doesn’t require switches to be grounded. If that has any effect on you in anyway
@aaron745 жыл бұрын
@@Nick-bh1fy Canadian CSA-listed boxes require grounding, whether steel or plastic. Plastic boxes have a metal strap jumping the ground screws in the back of the box to the mounting screws in the front of the box. By virtue of that, all devices marketed as "self-grounding" are grounded anyway, whether a pigtail was made to a device's ground screw or not.
@Nick-bh1fy5 жыл бұрын
Aaron Kaase yea I get u, I meant the switches themselves don’t need a bonding jumper directly to the box but yes the box it self needs to be grounded
@toddiman87395 жыл бұрын
Hey Ben! 1-Please get a pair of Klein lineman pliers and twist your joints first. I prefer ideal strippers with nm sheathing cutters also has 6/32&8/32 machine screw cutters. 2- i prefer ideal red wirenuts with wings for everything and ideal orange wirenuts for stranded fixture wires.
@BenjaminSahlstrom5 жыл бұрын
Thanks for the advice! There seems to be some debate as to if pretwisting is required. Someone recently said that it is required by code now? Where would I find that requirement? If you go by the manufacturer's instructions for the connector many times they state that pretwisting is not required. I realize that it does hurt to pretwist but I just want to understand the pros and cons. Wagos or push connectors seem like they are the way of the future since they don't damage the wires as much as pretwisting does. What do you think of them? Thanks for sharing your expertise!
@aaron745 жыл бұрын
@@BenjaminSahlstrom Nah, I think they are full of bull. The instructions for splicing lie with the manufacturer of the splicing device. If the manufacturer says to pre-twist, then you must do it in order for them to warranty their product and to meet the specifications of their UL listing. Workmanship is largely out the NEC's purview.
@toddiman87395 жыл бұрын
Benjamin Sahlstrom It’s not code but a good practice. Push on are expensive and you can’t beat a good joint.
@aaron745 жыл бұрын
@@toddiman8739 Agreed, I would use the push-ons or Wago lever nuts when I'm joining 5 or more conductors. I pretty much stop at the red wirenut. I don't want to use the big blue or gray ones, it just gets too messy and looks bad too.
@frankgorgone48795 жыл бұрын
Aaron Kaase sometimes you just have to have them big gray or blue guys though
@frankgorgone48795 жыл бұрын
Buchanan crimps for your ground wires works great and you can leave your wires long and use them as your pig tails for your devices
@TonyWadkins5 жыл бұрын
I was just thinking about that and started searching comments to see if anyone does that. I don't think it's against code, makes for a less congested box and makes all kind of sense !
@frankgorgone48795 жыл бұрын
It’s not against code at all. Actually inspectors like seeing it because it is a way better connection. 👍🏻
@wizard3z8685 жыл бұрын
Also great for connections that you don't want pple to mess with snap on a plastic cap almost as good as a weld been using em for 25yrs with the proper crimp tool
@frankgorgone48795 жыл бұрын
Yes I love crimp and caps are great
@wizard3z8685 жыл бұрын
@@frankgorgone4879 i will say though he did a great job getting it done with what he had. im sure you have been there when you need to get the job done and only have limited resources may not be ideal but its done safe and reasonable quality.
@rjwiderman3 жыл бұрын
I love your label idea. Surly beats using white tape to label, etc
@mikejustice11962 ай бұрын
What you prefer and what the NEC code requires is synonymous?
@chaecoco22 жыл бұрын
I noted that all the devices (switches) that you were using were standard switches. The head scratcher for me is trying to wire-in smart wifi switches which are wider and much deeper. All the wiring that you have stuffed in the back of the boxes makes getting those smart switches difficult to get into the box and screwed down. I am just curious how an electrician solves this problem. Thanks.
@ghostwriter310 Жыл бұрын
Ben, Thanks for a great channel. I have a question about multiple 3 way switches in the same J-Box. So, when you enter my Tiny House and on the left is a wall switch, with 4 different 3 way switches. Each 3-way switch controls a different operation. One does ceiling lights, the other does Front porch lights, the third 3-way controls the deck lights and the Fourth 3 way switch controls an outlet at ceiling level for a rope light (LED). I know I can run 14/2 from the panel to the J-box and get power to the switches. Here is where I'm a bit unsure! I need to run 14/3 to the other J-Box that has Four 3 way switches that operates the same as the front door J-box. Do I have to run 4 different 14/3 runs? is there a way to combine those runs onto just one run? and if so how might that work? Thanks for your help!
@mdvener5 жыл бұрын
Always twist the ends before installing wire nuts, red or blue wire nuts make more room in box, and alwys curl wire when attaching to device in same direction of screw, then tighten with FLATHEAD screw driver. Wago's only make a small contact point. Just like the stab loc on devices. Never use them n never will. After 40 years as a journeyman, have seen my fair share of burnt up devices or screws on devices loose from a phillips head drill or screw driver. Tinhgs need to be tight. Even newer devices with tab under the screw, i still curl the wire around the screw in proper direction. Doing service, way to many times pulling out devices, n the wire came off. Tight is right. I found that a no1 robertson bit works the best, even in a driver drill with clutch turned down, then test with flat head till you find the correct torque setting on your drill. No impact drivers. Nice job, just things i would have done a little different.
@turtleturtle49094 жыл бұрын
When two circuits are run into on box, is there anything special that needs to be done in the panel? For example, what happens if someone else come in later and thinks they have turned off one breaker but not the other?
@Nick-bh1fy4 жыл бұрын
You should always test to make sure power is completely off, don’t rely on believing the breaker shut off power entirely. Also keeping a clear panel schedule is very helpful as well
@wim01044 жыл бұрын
yep, you potentially (both meanings...) have 240V in that oulet box. always use your voltage tester or meter.
@sash93k3 жыл бұрын
For this reason, it is forbidden in Germany to install two circuits in one junction box.
@abrahamvaro7755 жыл бұрын
You make the best videos allways
@adisharr6 ай бұрын
Very good video - had a question about tying the neutrals together from two separate circuits and I'm glad I checked. Also curious to see how you handled all the grounds - I have a total of 10 in my 3 gang but I handled it in a similar way. Thanks!
@BonzaiMotionPictures5 жыл бұрын
Hi Ben, love your videos! I was wondering if you could do a video on wire nut sizes in depth. The biggest ones available to me are the gb ultra wingard 14-6 blue. It says min. 3 #12 and Max 5 #10. On the back it says 3-6 #12 and 5/6 #14. This confuses me a little. Does that mean a max of 6 14 gauge wires? I appreciate any info you can provide. Thanks
@BenjaminSahlstrom5 жыл бұрын
I'll get that added to the list! Thanks for asking!
@BonzaiMotionPictures5 жыл бұрын
No problem. Thank you!
@jibmaster3 жыл бұрын
Ben, Is it OK to run a jumper on a single circuit feed at a switch box for the commons and hots? I have one feed 14/2 wire from my main panel to the box which will also have to feed another box nearby. Along with all the wires for the switches needing to be wired I suddenly am needing to wire nut like 8-9 wires together. Jumping like you did with the grounds here in this video is what I am referring to. Thanks in advance.
@nicolasbernal45735 жыл бұрын
Happy new year! thanks for the help along the way
@drewjones3601 Жыл бұрын
If I have 12-3 wire coming in from two individual 20 amp breakers should I have a separate neutral wire ? I have a GCFI that keeps tripping but it takes like 12 hours before it does.
@matthewrinehart23674 жыл бұрын
I was taught to grab the bare ground with my linesman pliers and use it to split the sheathing.
@duanecarpentier15293 жыл бұрын
I have not found any good videos on adding a separate switch for ceiling fan when the power comes into the light. Would be great for you to do a video on adding another wire and switch for separate light and fan operation when power comes into the light. Lots of videos on how to do this when you have power coming into the switch first.
@allenstautz95063 жыл бұрын
Have a problem Ben with lighting circuit to bathroom. Installed 2 new outlets, 1 light switch to bathroom vanity. 1 outlet as normal. 1 outlet near sink a GFI. Above the GFI, a light switch for above sink light bar. PROBLEM- When light swich is OFF, lights have a dim glow. GFI tests/works fine. What can i check?
@LavaLiveLava24 жыл бұрын
always hook up the ground first, always remove the ground last. extra insurance in case of knicked wires.
@aurvaroy66703 жыл бұрын
That's what I do whenever I replace or install a switch or outlet.
@globalereps26033 жыл бұрын
I wired a similar switch box only with three switches and one separate circuit feeding a GFI Receptacle. I may have wired all the neutrals together consequently I have 60 volts at the light fixtures when the switches are off. Is this a back feed problem. Suggestions?
@jobaecker97524 жыл бұрын
Not an expert - but is there any problem when you tie grounds together from two different panels? Even if one is a sub-panel?
@claytonsprague73164 жыл бұрын
All grounds should be....ground potential so yes technically it does matter, they shouldnt be at different potentials from one another or have the possibility to be, ...please connect them.
@aurvaroy66703 жыл бұрын
As long as there's a main panel feeding a subpanel (or multiple subpanels), then there's no issue tying grounds together. In fact, they must be all connected to create a return path to the transformer. Now if it's two main panels, then there's a problem.
@robertmorgan81042 жыл бұрын
That cleared that up…thanks.
@Landesign584 жыл бұрын
Great video! I think Wagos would work better in this application, just my 2 cents....
@Vieweroffreedom3 жыл бұрын
What do you do if you're working after someone else, and you find separate mutuals in the same box that were tied together, but there's only hot power in? I can't seem just figure out neutrals on different circuits in the same box, but only one power in black wire.
@lockpickingvlad3 жыл бұрын
I like to leave grounds a little longer, twist them couple of times, then crimp. 😎
@venividivici42533 жыл бұрын
I think you could have used a red wirenut for simplicity for the grounds ;).
@TomCee533 жыл бұрын
Or a green with integrated pigtail
@venividivici4253 Жыл бұрын
@@TomCee53late comment but I did see those greenies before but was taught the old school way
@Akqayum3 жыл бұрын
Very helpful . Thanks
@simeonkaiwee91803 жыл бұрын
Thank you, I am benefiting from your's channel, I will like to know more from u. Am I allow ask? Thankyou so much.
@Dominic-jb1uf4 жыл бұрын
Nice work! Very informative.
@bcunitedsecretary29882 жыл бұрын
I am struggling with you tying the grounds together. This will make a ground loop at this box. How come this is legal ? Especially, when many circuits have to have GFI / Arc fault on them now this might interfere with that.
@NathanHarrison710 ай бұрын
Great video. Subscribed.
@PvPKingLP3 жыл бұрын
every german electrican be like there is bare copper in this fucking box
@opietwoep12474 жыл бұрын
I only worked with metal boxes and plaster rings some 30 years ago and nothing is worse than spending all that time wiring a box full of wires and when you have a device screw the shorted the wire out. I can still hear the breaker tripping and seeing and smelling the smoke from the square to round coming out of the ceiling fixture. I thought of that see the plastic box and the device screws are not exposed.
@johnmyers16723 жыл бұрын
Sometimes I catch a little bit of the wire insulation under the screw when installing a switch or outlet. Is that a big deal?
@TomCee533 жыл бұрын
Usually not, but it may make it loosen if the insulation degrades.
@chiefkookums93974 жыл бұрын
I'm a little confused by one thing. If there are two separate circuits coming into the box, why are the grounds from each circuit tied together as if it were all one circuit? Would the grounds from each circuit be spliced to their respective circuits ONLY?
@travispfeifer19794 жыл бұрын
Ground is ground.
@cengeb2 жыл бұрын
ground has to be all one ckt.
@aurvaroy6670 Жыл бұрын
Because grounds aren't current carrying conductors.; they only carry current momentarily when clearing a ground fault. For that reason, grounds are always tied together regardless of which circuit they're from. But yes, when bonding those wires, you can make separate joints for each circuit and tie them together to further indicate they're different circuits inside a box.
@zac3ne2nr5 жыл бұрын
Hey Benjamin, can you tie the neutrals in a 14/3 run together? Technically they're on separate circuits.
@ricker76er3 жыл бұрын
Separate circuits should NOT share neutrals.
@natedawe48944 жыл бұрын
Why would bonding the neutrals together cause a short circuit? Isn’t this what a shared neutral in a multiwire branch circuit does?
@jordansmith8914 жыл бұрын
8:21 I'm a bit confused as why you are pigtailing the hot wires here and where exactly they are going. Is the one black pigtail going to a separate box?
@jon_craftingo.o46863 жыл бұрын
The construction job he is working on is still in the middle phase. He said he is not fully installing the switches until after the drywall is up. By pig tailing the blacks together it is essentially the same as having a switch that is always on. Doing this allows the rest of the circuit after the switch (or in this case the pigtail) to be tested even if the switch is not yet installed. HTHs
@danielhernandez57023 жыл бұрын
Good job ,thank You
@pmheart64 жыл бұрын
Doesn't matter which side is up? Technically, but many homeowners prefer up = on and down = off plus the writing on the outlet says off right side up when down
@lordperezident3 жыл бұрын
True. It says no upside down lol
@rjwiderman3 жыл бұрын
When using a wire nut, use your nose wire strippers to grip the nut barrel! Works great in the field…all day.
@dogofcity4 жыл бұрын
0:56 min. i dont agree how youuse the knife.. you can cut your finger.
@kenairockband4 жыл бұрын
Learning a lot from your vids. Muchas gracias!
@danak9633 жыл бұрын
So could you have just twisted all 7 ground wires together tightly without using a nut, then cut off 4 of the unneeded grounds, and push them to the back of the box, leaving 3 of the grounds long enough to be used on the 3 switches? Or would that be against the code? Seems like a lot of extra steps to make 3 ground pigtails when you already have 7 ground wires to begin with
@aurvaroy66702 жыл бұрын
Cutting 4 off and leaving three for the switches would only be against code if those 4 short wires stick out less than 3 in from the outside of the box. Otherwise, there's nothing wrong with doing that, as long as you put a crimp sleeve (steel or copper) where those 4 wires end. In fact, this is how my house is wired and it saves space.
@MrTooTechnical5 жыл бұрын
Great vid. I am against the grain here, but when I wire circuits I ONLY put one feed per multigang box. I hate different neutrals and power feeds. This is just my preference. When time to kill the breaker, I ONLY ever have to find One. Lates.
@BenjaminSahlstrom5 жыл бұрын
I totally agree that that is the way to go if at all possible. It is so much cleaner and worth while to do it the way you suggest. Unfortunately not everyone does it that way so it is still beneficial for people to know what they may encounter from time to time. Thanks for sharing!
@aaron745 жыл бұрын
Ideally, yeah, one circuit per box keeps things far less complicated. Sometimes it's just unavoidable with how circuits land in the construction process, as I'm sure what happened in this case. It's usually not a deliberate design, just more circumstantial.
@travispfeifer19794 жыл бұрын
I’ve done boxes with three circuits hahaha
@jayparikh16642 жыл бұрын
Extremely helpful. You impressed me. I learnt a lot. I would like to talk to you personally. What is your email to contact you? Also, I need your guidance. I am trying to install Moes -Two gang 3way switch in the current two circuits switches. I can see power coming in the switch. But the lights are not getting turned on. This switch requires Line, Neutral and L1 and L2 Out.
@davcot36755 жыл бұрын
Great job. Only comment comes from industrial world. The line always feed on top. The Load always on bottom.
@BenjaminSahlstrom5 жыл бұрын
Thanks for sharing that. Is that a code mandated thing or just a best practice? You're referring to the connection on the switches correct?
@aaron745 жыл бұрын
@@BenjaminSahlstrom It makes absolutely no difference. If the switch required it, it would be marked on the switch.
@fatherelijah17633 жыл бұрын
its best practice
@PeterJamesPhotographyGallery4 жыл бұрын
Great video bud!!
@ReggaeRedeemer3 жыл бұрын
Its all about that roll
@bryanwight7655 жыл бұрын
As always, nice job Ben! Thank you
@BenjaminSahlstrom5 жыл бұрын
Thanks for being a subscriber! Out of curiosity, do you think I should start doing electrical videos exclusively on this channel? It seems that my non electrical videos don't do very well and some people even unsubscribe when I post them. Thanks for watching!
@bryanwight7655 жыл бұрын
Hell Ben, my primary interest is on the electrical instruction but I do enjoy a side topic now and then.
@darrenmoreno77235 жыл бұрын
Why not use any crimps for the grounds?
@BenjaminSahlstrom5 жыл бұрын
To be totally honest I don't have any experience using crimped grounds. What are the benefits of crimping versus using standard connectors? Maybe I'll have to research and make a video about crimping the grounding conductors. Thanks for asking!
@aaron745 жыл бұрын
I have heard those crimp sleeves are requires in some jurisdictions. Not here in MN. Just standard wire connectors are good here. Those crimps sleeves are super good, though.
@frankgorgone48795 жыл бұрын
Benjamin Sahlstrom I just left a comment on one of the benefits of crimps. Way less connections and takes up less room, also you can leave the wires long and use them as your pig tails for your devices. And the crimp is tight and way better then a wire nut.
@wizard3z8685 жыл бұрын
@@BenjaminSahlstrom Ben if you haven't yet see a cple of videos on them if you use the proper tool they hold as well as a weld and you can place a plastic cap over them very hard to get apart unless you know how just need to squeeze twice with lineman's and they pull off most noobs just cut them off lol been using em almost 25 yrs there almost a good tamper seal too many a job we went to and home owner cut them off and we nailed em with a service call instead of a warranty call back
@WeatherNut275 жыл бұрын
Hey Ben, can you do a video on floating neutral generator and bonded neutral generator? Differences and potential hazards and whys. Thanks!
@BenjaminSahlstrom5 жыл бұрын
I would love to! I've read some about the topic but am by no means an expert on it as of yet. I'll have to do some more learning before that one will be ready. Thanks for asking!
@WeatherNut275 жыл бұрын
@@BenjaminSahlstrom I had a customer wanting to put a cord on a furnace so she can plug into extension cord with generator when power went out. Told her it has to stay hardwired but found a cool product called EzGenerator Transfer Switch box which will be perfect. ezgeneratorswitch.com/generator-switch-installation/
@N-hunter5 жыл бұрын
Would love to see that
@davidschmoll55834 жыл бұрын
Great video! And yes, you're smart!
@robertochavez81964 жыл бұрын
Great job! Thanks for sharing!!!!!
@YOURJOURNEY3 жыл бұрын
I always connect the power at the top of the switch, so to turn on I switch up and to switch off I switch up..
@Automationacademytv5 жыл бұрын
Thanks
@anonymousperson43633 жыл бұрын
I thought all the LINES in an outlet had to be from the same panel. Also, maybe connected together in that panel.
@gamingandvloging11175 жыл бұрын
Good video but I would say it matters which way you twist the wire
@danniehughes95395 жыл бұрын
nice job
@MichaelMantion5 жыл бұрын
You should do a video about changing a 4 way light circuit to a 3 way. 4 way smart switches are much more expensive and don't have the same features as smart 3 way switches.
@BenjaminSahlstrom5 жыл бұрын
I have never seen a 4 way light switch. I believe that you really wouldn't need a 4 way smart switch as you could just use one smart 3 way switch on the first box where the power comes in. Then in effect you have control of all of the 3 or 4 way switches involved. Comment with the manufacturer and model of the smart 4 way switch you are talking about if you have it as that sounds very interesting to learn more about!
@MichaelMantion5 жыл бұрын
@@BenjaminSahlstrom Well I just changed out a 4 way to a 3 way and removed one of the switches. I am just saying a lot of people would like to see a video about it.
@aaron745 жыл бұрын
@@BenjaminSahlstrom Traditional 4-way switches simply reverse the travelers in-between the two 3-way switches. You can wire as many 4-way switches between the two 3-way switches as you want, because all that happens with both 3- and 4-way switches is they switch which traveler is getting current, and any other switch changes it back. Smart switches are a whole different and new thing. They are just electronic relays that switch 120V and use RF communications with remote switches. The "hub" switch is a single-pole relay and all the other switches are just remotes that mount in box and look like switches but are really just buttons that transmit RF to the hub to turn on the light.
@JoShUa_J782 жыл бұрын
Why would it trip right away?
@mr.3phase2285 жыл бұрын
I'd throw some tape around the switch, especially with them bare ground wires. Great vid Ben
@tompeters42345 жыл бұрын
Yea, I have started doing that by habit. Many moons ago I didn't with the older/smaller remodel boxes that were metal. Good Times back then.
@aaron745 жыл бұрын
You know, I did that for years and stopped doing so about 10 years ago. The main reason being is I found over time, the adhesive of the tape breaks down, and the tape sort of unravels itself and leaves residue on the device if you ever have to deal with it later. It's just not necessary... a bare ground should never come into contact with it if it's pushed to the back neatly as Ben did. Plus you may want to put a test probe on one of the screws while the device is mounted, and you can't do it with the tape in the way. It's definitely a good intention, to be sure, but I've determined it unnecessary and impractical in my experience.
@mr.3phase2285 жыл бұрын
@@aaron74 Ideal is coming out with those armour band insulators early next year, seems like a better option.
@aaron745 жыл бұрын
@@mr.3phase228 Armour band insulators? What's that? It goes around a device to cover its screws? I could see a fat rubber band could be a nice accessory. Thing is, there are a lot of electrical accessories and tools and that are nice, but not necessary...
@mr.3phase2285 жыл бұрын
@@aaron74 Check out Bill from Sparky Channel, the video is called Ideal Armourband insulating wraps coming soon!
@BearStar15 жыл бұрын
When one twists on the Wirenuts or Wingtip Connectors, they twist the conductors together as one screws them on !!!!!
@Justheory11b4 жыл бұрын
Sometimes.
@matylda48945 жыл бұрын
Video showing how to not contact a cable in XXl,
@matylda48945 жыл бұрын
Connecting""
@corbettknowles99425 жыл бұрын
If u liook at light switch it says on and off the switch wiring she be oriented for switch to work in that direction
@hreyn058 ай бұрын
why not strip the wires before you put them in the box?
@garryverniest58934 жыл бұрын
Where I live I do not believe we are allowed to run two different circuits into the same box.
@lordperezident3 жыл бұрын
Where do you live and how come?
@garryverniest58933 жыл бұрын
@@lordperezident I live in Manitoba Canada. It is a safety issue. When someone goes to work in the box they shut off a breaker figuring everything is deenergized in the box when it may not be.
@karlsmith88723 жыл бұрын
Wrapping the ground wire around the hot wire by itself creates a transformer inducing current into ground wire.
@williamstanton67105 жыл бұрын
All of those feeds going into box must be stapled/secured within 12 inches of the box per NEC Inspector will make you fix that
@BenjaminSahlstrom5 жыл бұрын
You didn't watch till the end of the video! Check again! ;)
@williamstanton67105 жыл бұрын
OMG Your right I skipped last 20 seconds Good Work
@BenjaminSahlstrom5 жыл бұрын
@@williamstanton6710 Haha I knew I would catch someone on that! It was way at the end so I don't blame you. Really appreciate the comment and thank you so much for watching!
@aaron745 жыл бұрын
@@BenjaminSahlstrom That was a very tidy job... lining up all the cables like that across that block.
@ricker76er3 жыл бұрын
If there are two circuits, why do you need three feed lines?
@TomCee533 жыл бұрын
The third wire feeds to another outlet or switch on the same breaker.
@BearStar14 жыл бұрын
They have these devices now that one puts into the chuck of a variable speed drill and it slips over the outer plastic shell of the wing tip or wire nut connector and it aids on putting them on and it makes it a lot easier than by doing it with your fingertips ! Amazon sells them ! www.amazon.com/gp/product/B0087TBPS2/ref=ppx_yo_dt_b_asin_title_o05_s00?ie=UTF8&psc=1