Surge Protection Device / Surge Arrester / SPD working principle / Best Explanation Ever..!😍💪

  Рет қаралды 200,035

Electro Academy

Electro Academy

Күн бұрын

Пікірлер: 100
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Hi everyone, Please Please Please.. Subscribe to the channel..! Its only a fingertip away from you..!😍💪❤🏆 Don't be selfish..😜 Just think about the effort I put into producing this video.🤔😎 Its totally free...! ❤❤ Also, Just a kind request to the viewers and professionals who can afford to sponsor or fund this channel, mainly for the benefit of the viewers all over the world.🌎🗺✈ It will also definitely be a motivation for me, to continue this channel with good explanatory educational videos for all of you. You can contribute by being a Sponsor of this channel using the following link, patreon.com/ElectroAcademy I made this request few months ago, and now one Patron has come forward to help this channel.💪💪 I love it from the bottom of my heart.❤❤❤ I know, many have become patrons of entertainment channels mainly, but look forward to see some more supporters who understand the value of an educational channel like this. Your kind gesture will be most welcome..!❤👍 Thank you and Best regards. Sudarshan, Creator of Electro Academy
@nobiechiks824
@nobiechiks824 4 ай бұрын
I have benefited, thanks. I also like the you explaining, clear and to the point
@ElectroAcademyEA
@ElectroAcademyEA 4 ай бұрын
Thank you
@kenstone8229
@kenstone8229 2 жыл бұрын
Great work. Very much appreciated especially your lecture in English language. It gains global coverage and more subscribers.
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you
@radhialiue1974
@radhialiue1974 2 жыл бұрын
Thanks to your hard work on This lecture it is very important to protective device
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you.
@sumanjana3862
@sumanjana3862 2 жыл бұрын
This is called exact tutorial video... It should get more likes. If there is option to give more than 1 like then I will surely do that.
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you very much.!👍❤
@kannankrishnan7740
@kannankrishnan7740 Жыл бұрын
Very good tutorial
@Tselectricals
@Tselectricals Жыл бұрын
Excellent presentation sir ❤❤❤❤, like it
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@tdauthantic
@tdauthantic 2 жыл бұрын
perfect explanation with all required details , many thanks for such a helpful information .
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you.
@sorinpetre6141
@sorinpetre6141 7 ай бұрын
Mulțumim pentru video
@ElectroAcademyEA
@ElectroAcademyEA 15 күн бұрын
Thank you
@ses5208
@ses5208 3 ай бұрын
Thanks for the informative video. What size fuses (normal or air?) do you recommend to place before the SPD? I have 16A 4P 230V coming in from the grid and 63A 2P 230V from local solar inverter.
@ElectroAcademyEA
@ElectroAcademyEA 3 ай бұрын
80 Amp fuses are recommended.
@govindandevadasan3252
@govindandevadasan3252 2 жыл бұрын
Very well explained. Recently I installed a 100kA surge protector from Dehn in my three phase connection in my home.
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you. 👍
@mohdiskandar6812
@mohdiskandar6812 6 ай бұрын
How to maintenance SPD to know is in good conditions from time to time?
@ElectroAcademyEA
@ElectroAcademyEA 6 ай бұрын
If the indicator stays green, SPD is in good condition.
@lee_brooks
@lee_brooks Жыл бұрын
Just what I was looking for, thank you : )
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@paanovlog3296
@paanovlog3296 Жыл бұрын
Can I ask sir ,if I have 70A main CB what should I put SPD type is can put 20KA?
@ntnblr
@ntnblr Жыл бұрын
One question for you . Where to install Voltage protector (like MCB) I have 2 meters: Grid and Solar
@aadedeelectric
@aadedeelectric 2 жыл бұрын
Good job brather..Thank you for sharing about spd
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you.
@thisismyhappydays
@thisismyhappydays Жыл бұрын
If I don't replace a failed SPD with a new one, would it make the RCCB (or RCBO) to trip (circuit break) more easily?
@ElectroAcademyEA
@ElectroAcademyEA 6 күн бұрын
If the SPD is short circuited internally, Over Current Protection Devices will operate. Also the RCD will operate and you won't be able to switch on the circuit until you disconnect the faulty SPD. However it all depends on the severity of the damage inside of the SPD.
@alimansoor78
@alimansoor78 Жыл бұрын
Do we need a dedicated earth bar, or we can connect the SPD to the existing common earth bar.
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
If the earth wire size from present earth bar to the ground rod is 10 mm2 or more, same earth bar can be used for SPD connection. If it is less, you need a separate earth wire with 10 mm2 or more, from SPD to the ground rod.
@joelgobeh7343
@joelgobeh7343 3 жыл бұрын
Can you please do a video on SPD sizing and advantages of the different types
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Ok. Will do.
@robertingersoll3039
@robertingersoll3039 2 жыл бұрын
Excellent video, beautifully explained.
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you.
@paanovlog3296
@paanovlog3296 8 ай бұрын
Can i direct connection of SPD in linr side no on the load side of Main breaker?
@bassamsalam4938
@bassamsalam4938 2 жыл бұрын
Thank you for these valuable information
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you
@iskandarzulqarnain4521
@iskandarzulqarnain4521 Жыл бұрын
Do we get electric shock when we touch any metal appliance which conected to the earth cable when the spd release the lightning volt trough the ground cable?
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Always better to avoid touching metal parts unnecessarily, since we don't know the magnitude of the current going to flow, when lightning occurs.
@alimansoor78
@alimansoor78 Жыл бұрын
So I think it's better to keep a separate dedicated earthpole for the spd to avoid any kind of risk
@shaunchetty4223
@shaunchetty4223 Жыл бұрын
Great video.. In a surge scenario, the SPD will ground the excess voltage but WILL it also trip the MCB??
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Even a high performing MCB will take more than 2 milliseconds to operate. Sudden transient voltages appear and dissapear within few microseconds. 1 microsecond is 1 millionth of a second. A good SPD will operate within few nano seconds. 1 microsecond is 1000 nanoseconds. It shows how fast SPDs act. MCBs are not capable enough to detect those transient voltages.
@shaunchetty4223
@shaunchetty4223 Жыл бұрын
@@ElectroAcademyEA so the breaker won't trip... Thank you for replying
@johnlennon6790
@johnlennon6790 Жыл бұрын
@@shaunchetty4223 yep and now we also know why. That's what good teachers do.
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you
@scottmoore-centralpeelss2571
@scottmoore-centralpeelss2571 2 жыл бұрын
If a 3 pole surge protector ( Siemens bolt shield) is installed in a home with 120/240 v, no 3 phases capability, will the surge protector still protect ?
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Standard 3phase SPD should work as long as you select matching voltage for single phase. For a 230 volt single phase supply, V RMS is 230V. V max is 325 volts. When you select with 10-15 % extra voltage, SPD should have 375-385 Volts value. Any two poles on SPD can be connected for single phase lines, keeping the extra pole empty. How ever, ask the manufacture first, since some sophisticated units may not work with one pole is without a phase line connected to it.
@davidclarke2513
@davidclarke2513 Жыл бұрын
What if I have a 230v supply feeding a split board with 2 rcds in the consumer unit
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
You can install Type1 SPD at main incoming line after the main switch. (Before splitting the circuit.) If two sub-distribution boards are available with equipment need to be protected, two SPDs (Type2) need to be installed in two DBs before the RCD.
@kuronekosan2830
@kuronekosan2830 Жыл бұрын
I live in a country where rms voltage is 230v So basically 325peak volt as shown in the video I want to order a surge protector online Same specs as in the video In 20ka Imax 40ka But with uc 275v In the video it says uc value shouldnt be near the peak voltage So can i still use that ? Even in my country here in store They sell ones with uc lower than peak voltage Also the up is 1.2 v is that better for voltage spike ? Or 1.5v is better? Please somebody help me with this asap Really need some help here
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
UC is maximum continuous voltage and is related to the RMS voltage. Since RMS voltage is 230 volts here, this SPD with 275 V UC limit is ideal to use. When consider the UP level, 1.2 V SPD, or even a one with 900 Volts is better than the 1.5 V unit for sensitive electronic items, but it should be used as the secondary SPD unit only. That means you should have a primary SPD with a UP level of around 2.5 V at the entrance then. Since we normally go for only one SPD unit for a home, better option is to go for a SPD type 1+2.
@kuronekosan2830
@kuronekosan2830 Жыл бұрын
@@ElectroAcademyEA i am just trying to protect my electronics from voltage spikes from power outage and surges Where i live, i don't really have any issues with lighting Do i still need to buy spd type 1 ? I also have spd type 3 on a power strip So i will have both type 2 and 3
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
If your area is free from Lightning issues, type 1 SPD is optional only. So you can go with Up 1.2 V SPD, and it has better protection level than 1.5 V SPD for electronic equipment.
@kuronekosan2830
@kuronekosan2830 Жыл бұрын
@@ElectroAcademyEA thank you for your help Really cleared up the confusion And very educative video Have a good day :)
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
@@kuronekosan2830 Thank you
@arvindkumar-kj6oq
@arvindkumar-kj6oq 2 жыл бұрын
Three phase ki spd me agar two phase lagaye aur nutral na lagaye to kya spd work karega
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
If a surge appears on any line connected to the SPD, it will by pass it through the earth wire to the ground. If Neutral wire is not connected, still the phase wires connected to the SPD will work. But, any surge appears or comes in to the house from outside on the Neutral line, surely can damage the equipment connected. That is the reason for connecting all the lines from outdoor to the SPD, before entering the premises.
@SanjayPatil-wu2id
@SanjayPatil-wu2id 2 ай бұрын
Why the subtitles is shown this way .. not able to see the video peoperly
@ElectroAcademyEA
@ElectroAcademyEA 2 ай бұрын
You can easily stop subtitle appearing, by clicking "CC" tab on the video screen. Thank you.
@MohammedHafazallah
@MohammedHafazallah 5 ай бұрын
thank you
@ElectroAcademyEA
@ElectroAcademyEA 5 ай бұрын
Thank you
@kenstone8229
@kenstone8229 2 жыл бұрын
How about SPD rating? Many thanks.
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Will try to do a video on this.
@nikkarunarathne4551
@nikkarunarathne4551 2 жыл бұрын
Can I use a three phase SPD device for single phase connection wiring at home with keeping other 2L s are free. Is it working?
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Yes
@udhaydeee
@udhaydeee Жыл бұрын
Can u do a video of SPD faults and how to reset ?
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
I will upload a new video about SPDs, within next 3 days. Hope you will find it helpful.
@KaiNaoJang
@KaiNaoJang Жыл бұрын
This is indeed informative except for your voice is crucial to listen.
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Thank you 😆
@janjanboquia6738
@janjanboquia6738 3 жыл бұрын
What software did yo uses to make this demomstration of the coonnection
@ElectroAcademyEA
@ElectroAcademyEA 3 жыл бұрын
PowerPoint animations
@janjanboquia6738
@janjanboquia6738 3 жыл бұрын
@@ElectroAcademyEA do you have toturial about it
@ElectroAcademyEA
@ElectroAcademyEA 3 жыл бұрын
@@janjanboquia6738 kzbin.info/www/bejne/noXUknpqabOlaZY Powerpoint tutorials are rare in youtube. Above is one on animation, but not about wiring work. I also just started exploring powerpoint on my own and practiced it.
@alfredgabriel8075
@alfredgabriel8075 2 жыл бұрын
Thanks
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you
@GSM_X_One88
@GSM_X_One88 2 жыл бұрын
Thanks Share
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Thank you
@drvivekbiswas2455
@drvivekbiswas2455 2 жыл бұрын
Difference between electromechenical rcbo AC type rcbo and A type rcbo
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
Will do a video on RCBO later
@keerthika776
@keerthika776 2 жыл бұрын
I think you connected reverse MCB wiring
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Selecting of the supply in and out of the breaker, explained in the video.
@ravisravi7815
@ravisravi7815 Жыл бұрын
Good equipments not damage føre ues to saruch
@hekmatadnan3146
@hekmatadnan3146 9 ай бұрын
👍👍👍👍👍👍🙋🙋🙋
@ElectroAcademyEA
@ElectroAcademyEA 8 ай бұрын
Thank you
@lingjiang3657
@lingjiang3657 3 жыл бұрын
Manufacturing Surge protecotor Devices .OEM &ODM
@ElectroAcademyEA
@ElectroAcademyEA 14 күн бұрын
Good
@rafiullah2861
@rafiullah2861 3 ай бұрын
Good work but quality of the video is too poor.
@ElectroAcademyEA
@ElectroAcademyEA 3 ай бұрын
🙄 thank you for the comment.
@Be-Always_Informed
@Be-Always_Informed 6 күн бұрын
@@rafiullah2861 did you mean video resolution or the quality of content? For me it s well explained.
@ElectroAcademyEA
@ElectroAcademyEA 6 күн бұрын
​@Be-Always_Informed Thank you
@georges8408
@georges8408 2 жыл бұрын
This diagrama refers only for CT1 type of connection and is wrong because in TT systems RCD should be before SPD and not after. Only in TNS is after. Also who the hell uses CT1 today ? CT2 is by far beter for TT and TNS for electricians
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
CT1 type is used at main switch board and if sub-distribution boards too are available, CT2 type should come on to the sub-panel. (CT2 type is not there as a replacement for CT1 type) CT3 or type 3 SPDs are also available and should be installed separately with specific systems when protection is needed for security cameras, telephone systems, PLC operation etc. Further, RCD is nothing to do with SPD. SPD is better to be fixed even before the main switch, but since it needs to be isolated when replacing or new one being installed, SPD comes after the main switch.
@rishardahamed5038
@rishardahamed5038 2 жыл бұрын
Hey Bro someone copy your video channel name # Tech Tips
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
We have started doing thesae videos in other languages also. It is the "Sinhala" language video of this.
@devnathsahni1075
@devnathsahni1075 2 жыл бұрын
Tell me in Hindi so that I can also understand. I don't know English.
@ElectroAcademyEA
@ElectroAcademyEA 2 жыл бұрын
Please try CC on settings. Goto settings > select captions > select auto-translate > select Hindi. You can read hindi translation on the screen.
@RoneelKumar-fd9wc
@RoneelKumar-fd9wc Жыл бұрын
Ats
@ElectroAcademyEA
@ElectroAcademyEA Жыл бұрын
ATS video is there. Please go to the channel and check.
Surge Protection Devices - Part 1
24:01
John Ward (jwflame)
Рет қаралды 217 М.
Mom had to stand up for the whole family!❤️😍😁
00:39
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 26 МЛН
Friends make memories together part 2  | Trà Đặng #short #bestfriend #bff #tiktok
00:18
Which Type of SPD should you use? ⚡
5:41
Axis Electricals
Рет қаралды 8 М.
Surge Arresters ; How do they works
7:19
sourabh sharma
Рет қаралды 77 М.
COMO MONTAR CUADRO DE PROTECCIONES FOTOVOLTAICAS - INVERSORES MONOFÁSICOS
11:22
ENERGY SAVING SOLUTIONS
Рет қаралды 218 М.
How Surge Protective Devices Function
10:41
MikeHoltNEC
Рет қаралды 11 М.
Surge Protection Devices - Part 2
20:06
John Ward (jwflame)
Рет қаралды 95 М.
Single Phase Electricity Explained - wiring diagram energy meter
10:10
The Engineering Mindset
Рет қаралды 3,3 МЛН
Mom had to stand up for the whole family!❤️😍😁
00:39