How to wire an indoor passive infra red sensor with tamper connected to IDS X-Series alarm panel
Пікірлер: 6
@quintonhamann10753 жыл бұрын
In this 2 years I have been following you I have learned a tones of things just from your videos thanks a lot my teacher hope I will one day transfer this to the future installers.. one question do you have a video on how to wire zone partition from the beginning..
@ecologicaltime3 жыл бұрын
thank you! i dont have such a video but i do have a new video showing how to connect different sensors to zones.
@aliaouel70852 жыл бұрын
i'm new in this field and im using a PIR sensor Honeywell DT-7235T and i want to connect directly siren 12v with it, when i test the sensor without the siren is work fine anyone can help me with the wire connection to the siren
@niceguy1000003 жыл бұрын
My installer, who happens to be lazy, didn't want to install tamper detection because of alleged interference problems. Can somebody confirm this? Or could I use separate zones for tamper detection?
@ecologicaltime3 жыл бұрын
i have not met one person who actually connects the tamper...don't know anything about interference, works fine. Tamper is useful for outdoor sensors and ones in critical installations where criminals can get tot he sensors like in warehouses during the day. - bypass the sensor and no one knows so they can break in later
@niceguy1000003 жыл бұрын
@@ecologicaltime Yes, I armed, walked up to the outside beam, removed the cover and I could have bridged the terminals easily. I should add the tamper resistors soon, this is nonsense as of now.