Пікірлер: 26
@boldford
@boldford 9 күн бұрын
A convincing argument to support individual micro-inverters.
@klmkt4339
@klmkt4339 6 күн бұрын
That's true. Even though the voltage of two panels same, if the internal resistance differs, it efficiency gets affected.
@klmkt4339
@klmkt4339 6 күн бұрын
I learnt it today bro. Thankyou
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 11 күн бұрын
Thanks COOP ...
@apanguronald
@apanguronald 5 күн бұрын
If you have two different charge controllers, can they be connected to one battery?
@sanhaoii7813
@sanhaoii7813 6 күн бұрын
Yes I install 3p 100kva already for customer it best. For use🎉🎉🎉🎉🎉
@jonlightsonnochaway
@jonlightsonnochaway 12 күн бұрын
So I have 3 mismatched panels in parallel. 1st one 18.1v, 5.50 amps, then 18v, 13.49 amps, 18.2, 16.5 amps. I had the smallest one first, then the bigger ones. At 1pm I was getting only getting 250 watts from all 3. I should have gotten over 600 watts using the lowest voltage of 18v and adding the amps. Now my question, is having the smallest panel first limiting the entire system? Say out of the 100 watt panel which was first, it’s like I was getting 80 watts x 3. Should the size and order of the panel make the difference?
@eddietee6305
@eddietee6305 11 күн бұрын
The order doesn't matter. His theory is wrong however.
@jonlightsonnochaway
@jonlightsonnochaway 11 күн бұрын
@ thanks for the clarification
@klmkt4339
@klmkt4339 6 күн бұрын
BMS function when adding up batteries
@klmkt4339
@klmkt4339 6 күн бұрын
Dc power loss vs ac power loss. My request.
@MusaJuwara-li8ir
@MusaJuwara-li8ir 9 күн бұрын
Now which one is better series and perallel
@Francesco105590
@Francesco105590 11 күн бұрын
Ciao , cosa usi per la grafica , disegno schemi
@fequiel509
@fequiel509 9 күн бұрын
🎉🎉🎉🎉🎉🎉🎉🎉🎉🎉
@dsmith6404
@dsmith6404 12 күн бұрын
😮
@eddietee6305
@eddietee6305 11 күн бұрын
Your theory on panels in parallel is wrong. The power company have different generators of different sizes connected to the grid all at the same time. The panels have reversing diodes as part of their circuitry. The effective voltage would not be the voltage of the smallest panel - it will be an average of the output voltage of the panels.
@asubhan2417
@asubhan2417 7 күн бұрын
I have tested this before and it is as it is as demonstrated in the video
@jm6604-c4d
@jm6604-c4d 6 күн бұрын
Wrong; the effective voltage will be the highest voltage panel, the diodes on the lower voltage panels will be reverse biased so there will be no current from the other panels. If you have different panels the only way to get efficient power from them all is a separate mppt controller on each.
@iorant2558
@iorant2558 5 күн бұрын
Yes but electrical company have a network that every generator entry in parallel under strongly rules and circumstances. 1) phase , 2)voltage , 3)frequency. Every generator gives to network the power that is made to give.
@eddietee6305
@eddietee6305 11 күн бұрын
Is he saying if one has a panel of say 45vdc output and another of say 24vdc output connected in parallel then the measured voltage would be the smaller of the 2? Incorrect. Not so. It would be an average of the 2.
@jonlightsonnochaway
@jonlightsonnochaway 11 күн бұрын
@@eddietee6305 so in parallel, it doesn’t use the smaller of a voltage, but an average?
@einyv
@einyv 10 күн бұрын
Not according to Rich solar:Wiring in Parallel When mixing panels with different wattages but similar voltages, the best way to wire them would be in parallel. To calculate this, you add the amperage of the two panels and multiply that number by the lowest Max Voltage between the two panels to get the total watts.
@aloeisthestuff9622
@aloeisthestuff9622 11 күн бұрын
I want to See the panel plugs tied to a Bus bar? You say it like they just plug together or something.
@Ricardofromage
@Ricardofromage 10 күн бұрын
Remove mc4, pare back sheathing, crimp bootlace ferrule, tighten busbar screwdown. Repeat until job done.🫡
@tomapetrovic6340
@tomapetrovic6340 9 күн бұрын
Wiring Mismatched Solar Panels To Get The Most Power
8:14
Everyday Solar
Рет қаралды 169 М.
Une nouvelle voiture pour Noël 🥹
00:28
Nicocapone
Рет қаралды 9 МЛН
Арыстанның айқасы, Тәуіржанның шайқасы!
25:51
QosLike / ҚосЛайк / Косылайық
Рет қаралды 700 М.
Don't Get Burned by MC4 Solar Connectors
13:41
eFIXX
Рет қаралды 292 М.
We seriously MISCALCULATED when we set up our Off Grid Solar System
16:43
Rustic Spirits Homestead (Regan & Kirsty Perry)
Рет қаралды 65 М.
How to Wire Different Sizes of Camper Solar Panels Together - Effects of Mismatched Solar Panels
12:19
EXPLORIST life Mobile Marine & Off-Grid Electrical
Рет қаралды 381 М.
How Many Solar Panels to Charge a Battery?
7:16
Cleversolarpower by Nick
Рет қаралды 202 М.
How Many 12V Batteries for 3000W Inverter
15:26
Cleversolarpower by Nick
Рет қаралды 523 М.
Bifacial Solar Panels are CHANGING the Game! Vertical Results Part 2
17:38
Projects With Everyday Dave
Рет қаралды 937 М.
How to Charge Batteries in Parallel With Different Capacity
8:22
Cleversolarpower by Nick
Рет қаралды 137 М.
Solar String Voltage Made Easy! How many solar panels can you safely connect?
14:11
DIY Solar Power with Will Prowse
Рет қаралды 262 М.
How and why to wire solar panels in parallel
13:18
EnergyUME
Рет қаралды 154 М.