Dang i been programing idec for a month, and never learned about the IDE prefferences. nice
@huntxtrm6 жыл бұрын
I notice this video turned out very blurry for some reason. I will try and correct that before the next upload. Any suggestions would be appreciated. I am using OBS to make these screen recordings.
@salvadormolinarelprofe79946 жыл бұрын
I teach PLC and have been to the training workshops for IDEC. You did great for a first timer very informative, like the way you explained every thing
@damlurker4 жыл бұрын
Nice Video! hey I'm an engineer but totally green on IDEC stuff since I usually work with Siemens and Allen Bradley.. :)
@huntxtrm4 жыл бұрын
Awesome! Thanks for watching. I am not an engineer! LOL. Just an electrician. I think you will like IDEC and the simplicity of the software as compared to Siemens and AB. I have dabbled around with both, and they seem complex in comparison. And very pricey, I will add.
@jlsmed4 жыл бұрын
Have an odd application. FC5A with HG3G-AJT22MF-W HMI. Need to disable a machine function using button on main screen and when this disable is on, blank or cover over sections referring to the setup of the disabled function on 3 other screens.
@huntxtrm4 жыл бұрын
Tell me more details. I will try and help you out. Sounds like you are needing to use triggers to see a button, or not to see a button?
@jlsmed4 жыл бұрын
So, the machine has two VFD spindles and each spindle can be programmed to run for different periods of time, speed, acceleration etc. the “program looks like a spreadsheet with all the different settings in a row for a period of time then it goes down to the next row of settings etc. there are pages of these settings. They now want the option to run just one spindle and want all the pages of settings to have the RPM column of set boxes to be covered over or something to indicate that the spindle is disabled. The RPM “set boxes have drop-down boxes that a value can be entered. I’m just not sure the best way to show they’re disabled.
@huntxtrm4 жыл бұрын
@@jlsmed i think what your looking for is a trigger. I am pretty sure you can make a data input box be triggered to be visible. You would have to use the input that brings that spindle on, as your trigger. I will pull up a program this weekend, and see if I can get something similar to what you want.
@huntxtrm4 жыл бұрын
@@jlsmed Ok, I have a video up. See if that is what you are trying to do? If not let me know, we can work through it..
@notcassie125 жыл бұрын
Texas represent!
@huntxtrm4 жыл бұрын
Present! And counted for!
@fijian08114 жыл бұрын
Hey Brother nice video. I am the sales engineer for IDEC in California. I could help you out if you ever need anything! Take it easy
@huntxtrm4 жыл бұрын
Awesome! There's that great customer support I talk about. Starting a project reverse engineering an old duct folding machine from Mitsi to Idec for a new customer. I think I will make a video series on it.
@kobibuhris9114 жыл бұрын
Hey Ricky, I am the sales engineer for IDEC in Israel, pretty much green and i would love to get any help to rebuild the IDEC brand in Israel, appreciate the effort.
@huntxtrm4 жыл бұрын
@@kobibuhris911 Thats awesome. Idec is good stuff, you will be sucessful with it. Keep up the good customer support on Isreal!
@FVA-si7zi5 жыл бұрын
Can you please make a video on PLC as Modbus Master sending Data to a Modbus Slave
@huntxtrm4 жыл бұрын
I will get this on the list. It might be a little while, time is tight here lately at work. But, hang in there. I will get to it.
@huntxtrm4 жыл бұрын
Still not forgotten, just been busy. Hang in there. I will get to it.