HVAC 090 TXV a deeper view of the Thermostatic Expansion Valve TEX TXV

  Рет қаралды 45,764

Love2HVAC with Ty Branaman

Love2HVAC with Ty Branaman

Күн бұрын

Пікірлер: 61
@jmead6121
@jmead6121 Жыл бұрын
27+ - years in & learned an Lot as always ......Thanks Ty
@Abdulrahman_Hi
@Abdulrahman_Hi 2 жыл бұрын
How are you able to explain so fluently and effectively?!!! Blows my mind many times!
@bluebeastgamer3005
@bluebeastgamer3005 11 ай бұрын
Obviously you are much better than my hvac teacher
@Raphael_NYC
@Raphael_NYC Жыл бұрын
It doe get better than Ty. His ability to diagnosis is exceptional. His delivery is kind, thoughtful, and chock full of experience. raphael nyc
@love2hvac
@love2hvac 8 ай бұрын
Thanks Raphael! I have some really good friends in NYC, I can't wait to return and visit!
@yonasweldekidan2077
@yonasweldekidan2077 3 жыл бұрын
Ty, you are one of the best hvac teachers on the internet. Thank u for the effort you are putting on to make this awesome videos.
@love2hvac
@love2hvac 3 жыл бұрын
Thank you. There are many better than I bit I do appreciate your complement.
@Vsmechanical_llc
@Vsmechanical_llc Жыл бұрын
Man,this is the greatest video explanation for txv,thanks for sharing you knowledge.
@dporrasxtremeLS3
@dporrasxtremeLS3 4 ай бұрын
Yes Ty, this was Fantastic! Thank you.
@luisbenitez3428
@luisbenitez3428 2 жыл бұрын
I concur. with the last comment before mine, this guy is a badass... Best TXV valve explanation bar none, thanks a lot keep the videos coming.
@nebraskaman8247
@nebraskaman8247 2 жыл бұрын
I’ve always called that stuff mastic, and I agree it’s a mess. Especially in the summer lol. Great video!
@rajuraghavan1779
@rajuraghavan1779 Жыл бұрын
Very good...👌👌Thanks🙏🏼❤️💜❣️
@lesliedaisley7846
@lesliedaisley7846 2 жыл бұрын
Bro I am knew to your channel your videos are very short well explained and not boring thanks for the information hope you keep up the good work, I really appreciate your videos being a junior tech its really hard to get the finance to take those expensive courses when you work pay check to pay check
@realestateservicessaleshea99
@realestateservicessaleshea99 3 жыл бұрын
Braze ! Braze ! Braze ! I know people get away with soft solder but the way I was taught, "Braze" Speed kills. Wait until the o-ring boys crap starts to fail ! I really appreciate the time and effort you put in to your videos! 🍇😎👍🏻 🥃🥃🍺🍺🍺🍿🏌🏻‍♀️ Stay safe. Retired (werk'n)keyboard super tech. Wear your safety glasses.
@hubercats
@hubercats 3 жыл бұрын
Great video, Ty! I wouldn’t have thought about the dissimilar metal issue but it makes perfect sense. Another thing that I find puzzling is why manufacturers even use copper brazing as opposed to using flare fittings. I can imagine brazed connections being somewhat more reliable but if flare connections aren’t reliable then why are they used at all? In a similar vein, it would seem sensible for valve manufacturers to increase the length of the piping to where brazed connections are made to help protect against the valve being damaged by overheating. Anyway, thanks for another highly informative video. - Best - Jim
@love2hvac
@love2hvac 3 жыл бұрын
You bring up great points. I think it comes down to cost. It cost more for the brass flared fittings and more manufacturing requirements to make those in the factory. Shorter tubes for the same reason. .10 over 100,000 units is nice bonus for someone. Thays my opinion anyway.
@jkbrown5496
@jkbrown5496 3 жыл бұрын
The equalization line, besides providing the valve with the saturation temp via the pressure, also bleeds off the liquid line pressurized refrigerant that will inherently leak around the valve shaft into the chamber below the powerhead.
@love2hvac
@love2hvac 3 жыл бұрын
Carrer installed some TXVs upside down and the same area below the power head would fill with oil.
@acrepairnearme
@acrepairnearme 3 жыл бұрын
Really like your explanation style.
@samersarah957
@samersarah957 3 жыл бұрын
You are wonderful teacher Ty, if the sensing bulb got leak how we know that? Thanks.
@love2hvac
@love2hvac 3 жыл бұрын
High superheat that you cannot adjust. it will give you the same symptoms as a a restriction Record Superheat, take the bulb and put it in ice water record the Superheat then heat the bulb up in your hand warning it up and record superheat. if the superheat never changed you may have a leak in the sensing bulb but a restriction clogged strainer can give you the same symptoms.
@davidfloyd6084
@davidfloyd6084 8 ай бұрын
no in all my years. ive changed quite a few. but maybe only a handful were truly bad. others were damaged due to poor service, burnouts, trash in system, screens clogged. they really dont go bad that often unless service incorrectly. i love staybrite 8 and love it. use it myself but there are people out there that use too much solder or flux or both
@YB-eg3rj
@YB-eg3rj 3 жыл бұрын
Wow. Who uses soft solder!! 🤦🏻‍♂️🤦🏻‍♂️ Good video 🔥
@love2hvac
@love2hvac 3 жыл бұрын
I see it all the time. Ugh
@kyawthuhan4092
@kyawthuhan4092 Жыл бұрын
Really nice video. Thank you very much.
@cincinnatusaurelius8371
@cincinnatusaurelius8371 Жыл бұрын
I believe pin was installed upside down. Refrigerant couldn't flow the way it was in there during description.
@mtbbiker6401
@mtbbiker6401 Жыл бұрын
Wow, what an awesome video and channel. I wish I could hire you to service my heat pump in AZ! In order to test TXV using superheat method, must the system be properly filled? I had a tech tell me my lack of cooling is most likely due to TXV but can't be certain. Now I'm researching how to diagnose faulty TXV. The subcooling was only 1 degree when it should be 10 degrees on my heat pump. The tech supposedly added 2lbs of R410A. That only gained another 1 degree of subcooling so now has 2 degrees. He didn't feel comfortable adding additional refrigerant. I'm worried that not enough liquid is getting to the TXV if my charge is super low. I cleaned my condenser coil the best I could, silly trane spines. Other than low refrigerant, what other things should I look for that causes low subcooling? When the system initially runs after a period of rest, the suction vapor line is nice and cold, "beer can cold" at the evaporator, then it becomes closer to ambient temp after 5-10 seconds. Could that be a sign of restriction or low charge?
@kriscook3737
@kriscook3737 Жыл бұрын
do you need to recover the refrigerant to replace the power head?
@love2hvac
@love2hvac Жыл бұрын
Yes
@Vsmechanical_llc
@Vsmechanical_llc Жыл бұрын
Question: is that an easier way to check the txv without checking the charge? for example: if I just check the temperature before and after the txv can I tell if it's bad?
@love2hvac
@love2hvac Жыл бұрын
Measuring superheat is the only way to check aTXV since it's trying to control superheat. Measurquick app has a method to check the charge of a system without using gauges, called non invasive testing. You will need the full probe set but search Measurequick non invasive testing and you will find an article on that. Non of the methods uses temperature drop across the TXV
@moonlightacmaintenance3232
@moonlightacmaintenance3232 2 жыл бұрын
Food for thought: if the sensing bulb is subjective to temperature from outside sources hints the need to wrap it with insulation tape is the capillary tube between the bulb and power head equally influenced ?
@love2hvac
@love2hvac 2 жыл бұрын
Great question. I do have a friend that sprays insulation on that tube but I find it unnecessary. The liquid vapor mixture is inside the bulb itself also factored the volume of the bulb. The size of the capillary tube is small, very low volume. So yes it possibly could play a factor but I overall such a small amount it's not worth the worry. Airflow, ductwork, filters, home air sealing, refrigerant lines and bends play a bigger part. All TXV have a swing as well. They won't maintain a precise superheat. When that becomes a factor an EEV is the go to because it will keep the superheat on point and precise. I love that your thinking about it!
@moonlightacmaintenance3232
@moonlightacmaintenance3232 2 жыл бұрын
I’ve seen some units where the txv is in the air handler and the bulb is on the suction line on the outside of the air handler (wrapped) I just wondered about the influence of the air temp between point A and B. Thanks for the response.
@love2hvac
@love2hvac 2 жыл бұрын
@@moonlightacmaintenance3232 Yep. That's the best way! Next time I get to talk to an engineer or a lab test person I will certainly ask and get you a better answer. Im always impressed where those conversations lead. Thank you for bringing it up.
@moonlightacmaintenance3232
@moonlightacmaintenance3232 2 жыл бұрын
Here’s another odd question, if I have a leak on my vapor side in a 410a system should you A) pump down the system and repair and top off charge after or B) recover and repair and recharge with virgin refrigerant? The reason I ask is fractionation a issue because it’s leaked out as a vapor opposed to a liquid ?
@love2hvac
@love2hvac 2 жыл бұрын
@@moonlightacmaintenance3232 Fracination is not an issue with 410A. The 2 refregerants are so close together. Many tests have been done with this. A friend worked in a testing lab and they found even charging 410a as a vapor was not an issue. I will still recover and charge all new refregerant, because I don't know the practice of the last person that serviced it. Did they pull a proper vacuum? Did they mix refregerants? Did they properly purge their noses each time it was serviced? All these unknowns is why new refrigerant is cheaper.
@stroodles42
@stroodles42 3 жыл бұрын
Great stuff. I think for those cutaway moments with diagrams and such, it would be a much nicer video if you added some soft jazz music or elevator music. Some kind of sound would make it much more pleasant
@love2hvac
@love2hvac 3 жыл бұрын
I will see what I can do for next time. thank you for the suggestion.
@111000100101001
@111000100101001 2 жыл бұрын
Any experience with AC Renew? I’ve heard it’s a product that helps with older systems and can weaken trace acids.
@love2hvac
@love2hvac 2 жыл бұрын
A compressor manufacturer a while back had an issue with a rust inhibitor that reacted with POE oil and it gummed up TXV's and AC renew was the only thing that seemed to help that. As far as acid goes, I'm not a chemist but the one I talked to had a lang explanation that essentially said what ever gets rid of acid either is a base and must me chemically balanced in quantity ot it will turn back to water that will turn back to an acid. I do not have anything in writing to back that up so do your own research. I had 2 commercial systems that had noisy compressors but where running good. I added ac renew and they were still noisy and died 6 months later. I don't think the AC renew caused the failure but it certainly did not help with anything. Manufacturers spend so much money marketing their products it makes it impossible to find the truth. Long story short I would use it for the specific issue of oil additives where the manufacture suggested it but I would not spend the money behind that.
@idontwantachannelimjustcom7745
@idontwantachannelimjustcom7745 3 жыл бұрын
In electronics soldering, they sometimes use a non-corrosive flux. I think kester makes a pen. Would that work for soldering pipe to prevent corrosion failure maybe?
@love2hvac
@love2hvac 3 жыл бұрын
I do not know. I have yet to see any manufacture of residential or commercial equipment use soft solder from the factory as they are always braze (silversoldered) . The manufactures spend a lot of time testing a variety of methods. I think, if soft solder was a viable option at least 1 manufacture would be using it. I think instead of improving a inferior method to make it slightly better we could just braze it properly with an inert gas and never have to worry about it again. I would rather see the fast push on connection as they would at least be easier to fix. Fixing soft solder connection is one of the things I despise doing.
@idontwantachannelimjustcom7745
@idontwantachannelimjustcom7745 3 жыл бұрын
@@love2hvac sorry. I like to solve problems with things. Also youtubers in general have trained viewers that comments feed the algorithm. "Here algorithm have a cookie" isn't a very well thought out comment, so I try to pose interesting questions. Also I believe there was an hvac youtuber that to paraphrase, mentioned we should always be exploring, learning new things, and new techniques. Otherwise we would still be charging systems by feeling the pipes.
@love2hvac
@love2hvac 3 жыл бұрын
Oh I love your thought process. I apologize I should have worded that better. Soft solder has just left a sour taste in my mouth over the years. I've also received a good bit of email from the loyal soft solder members trying to recruit me to the dark side. I apologize for comming across harsh. A company called solder weld would be a great reasorce for they diffrent types of Rossen core (non corrosive). Looking at new methods and solutions is great. Dont let anyone stop you from exploring ideas. I was contacted by Parker/Sporlan today. They have a new products the want me to look at a new product called the zoomlock max and now a zoom lock push for connections. Hopefully I can check them out soon. I don't know about the algorithms I dont even consider myself a youtuber. I just want to be able to help some people. I still have a lot to learn about HVAC and I'm a complete noob at the KZbin thing! Thanks for your patients and never stop learning.
@mikafoxx2717
@mikafoxx2717 3 ай бұрын
That's what confused me with plumbing - acid solder. Coming from electronics work, practically zero solder uses anything but rosin except for the kind used for oven soldering boards that get washed after. Rosin is simply pine resin and isn't horrible to breathe either. It's probably less effective but you need clean connections anyways. Perhaps rosin has it's own issues if it mixed with oil or dissolved in any refrigerants.. I don't know. I agree that fancy new press fit designs are fascinating in their own right, I would hope to see more fancy silicone rubber gaskets used which shouldn't degrade as much over time or with heat.@@love2hvac
@felixfernandez442
@felixfernandez442 5 ай бұрын
👍exelent
@jollyscaria1922
@jollyscaria1922 Жыл бұрын
Welcome shering good testing and adjusting thermostatic expansion valve. To test adjusta new tx vor valve wich is out of adjustment follwing tools and materials are required a srevice cyinder of refrigent 1 R12 . R22 to supply 70 psig pressure. A highpressure gaugeto indicate valve in let pessure anda lowpressure gauge compoumd )to indicate valve out let pressure samll quantity of crushed ice in a n insulated container proced as follws to adust valve .. the oen the sreice cyinder build 70 psg warom the cylinder if required on thehigh pressure age conected in the line the vlve inlet the expashion vlve ca now be adjusted the pressurethe our letshold be equal to the pressureof the refrigentto be chargedinthe systomattemperature 22°f if 10°f super heating is rquired the temperature ofthermal bulb is 32 °fthe superheatingis to be 10°fthen the temperature of refrigerant will be 22°f and pressure mustbe adjusted to much this 22°fthe pressure on the out let gauge should bs differnt for various refrigerants astap bodey of the valve lehtly oder ti determine if the valve is in soothe operation the poiter of low pressure guge shold not jump more lode adjist jest drmi spring adustinv only lord and slowly exp gas r22 22psig r22 ..45 psg is ..ok gues opershoion welcome...
@matthosseini4194
@matthosseini4194 6 ай бұрын
👏👏👏👏🙏🙏
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 жыл бұрын
Cork Tape is horrible. It is extremely messy. I definitely like foam tape over cork tape
@syedbasheer8210
@syedbasheer8210 3 жыл бұрын
👏👏👏👏✅
@CooperArmstrong-y4m
@CooperArmstrong-y4m 2 ай бұрын
Jackson Elizabeth Gonzalez Sarah Thompson Angela
@jollyscaria1922
@jollyscaria1922 Жыл бұрын
Vrey nic full and reding bacical bai organnl cs ok
@coldfinger459sub0
@coldfinger459sub0 3 жыл бұрын
I learned something new today about the position of the two tube sticking out of the Sensing bulb either I forgot I learned long ago and faded out a memory or didn’t pay attention closely enough to the readings or instructions for my father as a child. Doesn’t matter how many decades you’ve done something if you haven’t learned something new every day you’re not doing something right. Got a love those guys who swear by StayBright 8. And because they’ve been doing something for decades usually ( that makes it right) find that there are stubborn as a log and deny they caused any harm. Even if you show them. Deeply ingrained cult religion following.
@hhenrynice6843
@hhenrynice6843 Жыл бұрын
Some ppl can use it correctly and not have problems. So those ppl are not wrong. It's if you did not learn how to make it work is when there is a problem. So it appears depending on situation you and them are right. When done right they are right.
@coldfinger459sub0
@coldfinger459sub0 Жыл бұрын
@@hhenrynice6843 you are correct 👍. I did come across one Job were 8 spit systems installed with StayBright 8 . I was the nicest install system I have ever seen on the Brazing job , none leaked. But 4 out of 8 leaked at the flair fittings. That was the first time I ever gave a StayBright 8 job a thumbs up 👍 in one of my videos on a R410 system.
@wasimedoo7994
@wasimedoo7994 Жыл бұрын
One question bro how do you know the in and the out of the TXV and if you put it wrong what going to happen thanks
HVAC 092 Automatic Expansion Valve AXV AEV and  evaporator pressure should be
23:55
Love2HVAC with Ty Branaman
Рет қаралды 13 М.
СКОЛЬКО ПАЛЬЦЕВ ТУТ?
00:16
Masomka
Рет қаралды 2,9 МЛН
这是自救的好办法 #路飞#海贼王
00:43
路飞与唐舞桐
Рет қаралды 138 МЛН
What's inside a Thermal Expansion Valve TXV - how it works hvac
7:51
The Engineering Mindset
Рет қаралды 945 М.
HOW TO ADJUST A TXV ON A WALK IN FREEZER LIKE A PRO
8:56
Dnoorian
Рет қаралды 169 М.
(TXV) Thermostatic Expansion Valve Operation with Pressures! 3 HVAC Scenarios!
6:45
HVAC 087 A. Connections part 1 Brazing,  introductory only
16:27
Love2HVAC with Ty Branaman
Рет қаралды 4,8 М.
HVAC 129 Faster Recovery
15:29
Love2HVAC with Ty Branaman
Рет қаралды 97 М.
Why and How to Adjust a TXV / TEV
19:15
HVAC School
Рет қаралды 446 М.
СКОЛЬКО ПАЛЬЦЕВ ТУТ?
00:16
Masomka
Рет қаралды 2,9 МЛН