HVAC 142 Vacuum P9 Inside the vacuum pump

  Рет қаралды 7,166

Love2HVAC with Ty Branaman

Love2HVAC with Ty Branaman

Күн бұрын

Пікірлер: 20
@TheGibby3340
@TheGibby3340 2 жыл бұрын
Great illustration of failure to rid the pumps life blood of moisture. Thx very much 👍 If this doesn’t make the point about the importance of pump maintenance, I am not sure what would.
@Dimi3sX
@Dimi3sX 8 ай бұрын
Great job!!! explained in the proper way,thank you!
@jpadgr8
@jpadgr8 2 жыл бұрын
Thank you for this amazing video. Very educational.
@realestateservicessaleshea99
@realestateservicessaleshea99 2 жыл бұрын
That was a very good video. Thanks again!👍🏻 🥃🥃🍺🍺🍺🎯🏌🏻‍♀️
@love2hvac
@love2hvac 2 жыл бұрын
Thank you
@samersarah957
@samersarah957 2 жыл бұрын
Thankfully for great illustration Mr.Ty. If used one stage vacuum pump will do the same job as 2 stage? What about the cfm as the number is higher the vacuum will be deeper is that correct? (Of course with using core removal and large hoses). Makita has a vacuum pump 1 stage and I think 2 cfm cordless do you think that pump could do the job? Thank you.🥀
@love2hvac
@love2hvac 2 жыл бұрын
I need to run some comparisons between a 1 and 2 stage.
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 2 жыл бұрын
Lower CFM should result in a deeper vacuum (a lower ultimate pressure), time to reach ultimate vacuum will be longer though. A single stage pump could theoretically reach a deeper vacuum than a 2-stage pump due to tighter tolerances, less internal leakage, but of course will take longer. I use a single stage pump with a small motor running for 12 hours or more if the system is old and has had contamination issues, virtual leaks (outgassing) can require quite some time (beyond 12 hours) to resolve in this case. If the system is clean and dry, a 2-stage pump will pull a nice vacuum in a short time, the larger the system, the 2-stage pump is faster. I think the Makita 1-stage 2CFM pump would work fantastic for evacuating a typical residential system.
@rogergregory6512
@rogergregory6512 2 жыл бұрын
So should we be tearing down our pumps like this on a regular basis? Can you buy these parts for replacement?
@love2hvac
@love2hvac 2 жыл бұрын
No sir, keep the oil changed and it will last. You your career. However if it's been abused, or if you do a blank off test and it's not pulling down then yes.
@dporrasxtremeLS3
@dporrasxtremeLS3 8 ай бұрын
@@love2hvac Blank off Test? Very interesting?
@vvrao7006
@vvrao7006 4 ай бұрын
Niche demonstration.. vvrao, IIT Tirupati, india
@vvrao7006
@vvrao7006 4 ай бұрын
Nice not niche
@rodsbmwadventures5663
@rodsbmwadventures5663 2 жыл бұрын
Hey Ty what is a good suggestion for a beginner vac pump?
@love2hvac
@love2hvac 2 жыл бұрын
kzbin.info/www/bejne/rofPZ2Wiqryiha8
@nadirnadir1358
@nadirnadir1358 Жыл бұрын
i have question the vanes of the secend stage (small stage ) but the first stage is fine and i can't find the vanes in markert the question is can i use in normaly with only the main big stage
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 2 жыл бұрын
Doesn't seem like removing 14.7 psi of atmosphere would be a difficult task requiring careful preparation and specialized equipment, does it? After-all, it's only 14.7 psi... Yet, we can never evacuate all of it! ;)
@love2hvac
@love2hvac 2 жыл бұрын
Exactly! its so cool! only 14.7 but so evasive! The true missing piece of the puzzle is not only pressure but also lack of molecules. trying to get those last molecules out is the real challenge.
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 2 жыл бұрын
@@love2hvac Yes, the definition of vacuum is absence of molecules. These molecules of contamination (non-condensables) must not be allowed to interfere in the process of evaporation and compression of refrigerant. In order to remove these molecules of contamination, they must find their way into the vacuum pump. At 1st during the evacuation process, the molecules still remaining in the refrigerant tubing bump into each other, pushing the others into the vacuum pump but as pressure decreases, there are fewer molecules to push other molecules towards/into the vacuum pump, thus rate of pressure decay slows, and the mean free path of the molecules becomes longer.
@love2hvac
@love2hvac 2 жыл бұрын
I completely agree 💯
Vacuum pump teardown
12:08
Curious HVAC Guy
Рет қаралды 22 М.
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 48 МЛН
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 15 МЛН
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 1,8 МЛН
SLURRY TANKER VACUUM PUMP REPAIR AND MAINTENANCE
20:26
FARMER PHIL
Рет қаралды 60 М.
How To Pull A Vacuum In Less Than 10 Minutes   - The BEST Way-
8:41
The DIY HVAC Guy
Рет қаралды 77 М.
The EASIEST DIY Vacuum Chamber You Can Make
9:31
Paul's Garage (Paul's Garage)
Рет қаралды 106 М.
Vacuum Pumps Explained - Basic working principle HVAC
6:54
The Engineering Mindset
Рет қаралды 1,5 МЛН
How gas pumps know when to turn themselves off
13:56
Steve Mould
Рет қаралды 14 МЛН
Servicing The Vacuum Pump
6:58
Mitty Supply
Рет қаралды 5 М.
Don't get Hosed! Use an Engineered Solution for Vacuum!
11:37
AccuTools
Рет қаралды 11 М.
HVAC Tips to Avoid Vacuum Problems! Top 15!
17:35
AC Service Tech LLC
Рет қаралды 217 М.
HVAC 147 Vacuum p14 Example 2 single hose setup
20:23
Love2HVAC with Ty Branaman
Рет қаралды 23 М.
Robinair A/C machine vacuum pump replacement and operation
17:06
Watch Wes Work
Рет қаралды 26 М.
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 48 МЛН