Thanks for the explanation, my MRCOOL unit control board fried and I ended up with an H6 code after replacing it. After checking resistances like you explained on the fan motor, I ended up with OL so I’m ordering a new motor now. The voltages you specified coming out of the control board were spot on. Thanks bro
@2112user14 күн бұрын
Thanks for the explanation, I wonder... is there a way to power these outside the unit? I got one where I have a intermitant vibration issue, the motors are not easily accessable, so aside from just swapping both or and moving it around, had to tell which is the issue, or even if it's motor and not a fan blade issue. Powering them up to spin would help in diagnosing mine.
@izzybell112 жыл бұрын
Interesting topic. Well presented and explained. Great job JMT.
@jollyscaria192210 ай бұрын
Vrey good welcome shering gues tjankyou my berthers dc motr restance dc fan moter series conted some unit ficing very good thankyou
@daveswoodworks26027 ай бұрын
Very well explained, This helped me alot!
@JumpermanTech7 ай бұрын
I'm glad this video helped. Thank you very much! Stay tuned for new videos every week🔧⚡️
@mattalexander89192 жыл бұрын
In heating it’s a condenser fan motor too.
@lasersbee Жыл бұрын
Very Well explained... Easy to understand. I have a question on a Mini Slit compressor Pump Motor "How to Check" ? like this Video
@Link_aura2 жыл бұрын
im just happy this vid was in English
@مرتضینیستانی-ز5و5 ай бұрын
Great education 👏
@JumpermanTech5 ай бұрын
Thank you! Stay tuned for new videos every week🔧⚡️
@fabioalves-qf8ms Жыл бұрын
Hello, 👋. I am sorry, if I received any voltage from blue ( signal rpm) ? I have voltage, but in the blue in have nothing. And my motor is not running…. But i have voltage in feedback….. and I have to 310v and 15vdc on wh…..
@sv6k0a392 жыл бұрын
Did the manufacturer provide you with info on the resistance and voltage values?
@narayanaya5519 Жыл бұрын
Hi friend could you please let me know the details about what is the purpose voltage between GND AND VCC , what is the purpose voltage GND AND VSP , and finally Fg means what could please send reply .I am ur subscriber 🙏
@notashamed7563 Жыл бұрын
Thanks!
@thesilentonevictor2 жыл бұрын
Great video tech
@nicolerennie2 жыл бұрын
very useful & helpful video, thank you for sharing! ⚡️✨
@complex_variation10 ай бұрын
Hello: I have a GE AHTR12 that I'm repairing I just noticed something odd in my case that I would like to point out, I have the following readings from the main PCB to the motor: RD Vm = 317 V BU FG= 4.9V YE Vsp= 0V WH Vcc= 14.9V BK GND The "legend" or symbols of each wire I got it from the my motor's sticker. So the odd thing here is, that I do get a voltage on BU FG, but not on Vsp. Again I measure it coming from the PCB. Anyways I'm wiring it the same way how it came from the manufacturer, so I just wanted to point it out if someone finds this useful.