HVAC REFRIGERATION: Walk In Cooler running warm, Headmaster surprise!

  Рет қаралды 36,763

Rookie Refrigeration

Rookie Refrigeration

Күн бұрын

This WIC was running warm and found multiple issues. Compressor contractor, condenser fan motor capacitor and a major headmaster issue. Flashing sight glass, high head pressure, and hissing TXV.

Пікірлер: 266
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Guys, plenty of y’all have stated that “I could have pinched off the discharge line”. Yes I know that. But I will not do anything without an approval. This customer always finds away to not pay the bill so I will not do anything that will put the company at risk or I will not do anything without an actual approval. That’s the reason why I left it as it was. It’s been like that for who knows how long. So???🤷‍♂️
@anthillmobstars
@anthillmobstars 4 жыл бұрын
Rules are rules. Plain and simple. You do what you have to. Not what you want to. It's hard to understand sometimes, but you're doing what you need to.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
👍👍
4 жыл бұрын
You know what I do with customers who bitch about and pick apart bills when they issue a NTE that barely gets diagnostic time much less any repairs? Tell em the phone book is full of other guys. Call them, and lose my number please. If I wanted to do volunteer work I’d join the peace corps.
@48retrop
@48retrop 4 жыл бұрын
@ Nice attitude dude. I'll bet you have more business than you can handle.
4 жыл бұрын
And I’ll bet you will take anything and everything that comes along including shit which I take none of. My customers respect me and request me because I treat them fairly like adults. You obviously have no experience with brokers or national account customers otherwise you would know they are assholes who think they are doing you a favor by allowing you to work on their shit. A NTE that is eat up with travel time by the time you arrive, check in lines, check out lines, take and email photos of this, submit that, then wait around to see if we approve what you say the problem is. I’m not the one with the attitude son, they are. I don’t jump through hoops for anyone. Almost 30 years in the field bud. More than likely Ive forgotten more than you currently know.
@wh1zkidd
@wh1zkidd 4 жыл бұрын
Your videos are awesome! Please show even the beginner stuff, don't assume your viewers know everything, in fact quite the opposite. More of your subscribers are trying to learn and are not expert techs bored on a Sunday that wanna watch videos for fun. We're trying to learn the business from someone like yourself to better ourselves and make more money. Thanks and keep up the good work! You are very good at what you do and it is appreciated by business owners and us subscribers!
@thetman2301
@thetman2301 4 жыл бұрын
j kelz the problem is that you can’t show all of the basics all of the time in every video. I get your point but there is plenty of videos on other channels as well that show that. He’s pretty much going through the troubleshooting of his work. If you know the basics of refrigeration you can see his process better and understand it. After you watch a video just look up the part that you don’t understand. That’s how I do it and it’s getting easier to do on my own out in the field.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yeah man, my videos are already 13+ minutes, which I think is long. If I had to go through alot more basics, id have extremely long videos. But I'll try to get some better beginner info. Thanks for bringing it up.
@jayxiao3
@jayxiao3 4 жыл бұрын
Best headmaster removal of the year.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
You’re not kidding. Lmao
@brandonprice3927
@brandonprice3927 4 жыл бұрын
After finding the headmaster missing, it was time to walk away. They don’t want to pay. But I agree that you were right in doing what you did.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Thank you so much. Finally someone who agrees. 💪🏼💪🏼
@isaacmartinez3222
@isaacmartinez3222 4 жыл бұрын
@@rookierefrigeration4357 there would be a couple weeks of work at every location we service if we didn't need authorization. You can't charge someone for something that wasn't authorized. Where im at we're now getting signatures before we touch anything, , use to not be that way but people will look for a way to get out of paying.
@yomomma9070
@yomomma9070 3 жыл бұрын
@@rookierefrigeration4357 I agree too. I've done work for many gas station owners before. And none of them like to pay. If you would've touched that piping you would've been held accountable had something went wrong after you left.
@OcRefrig
@OcRefrig 4 жыл бұрын
We All know if That Cooler is at temp , No Repairs will be authorized by anybody. it would be a Christmas Miracle !
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
OcRefrigeration , Hvac & Electrical Video's. Lmao. I know. Everyone is saying “you could’ve pinched that line off”. Or do this. Lol. Nope. Not without an authorization
@isettech
@isettech 4 жыл бұрын
Pro tip. To save time, prevent incorrect wiring, with the power off, only one of the two terminals need disconnected to test a cap to isolate it from the motor. Then the wires can be returned to the empty terminal without risk of swapping a wire.
@josemartinez-jt6tw
@josemartinez-jt6tw Жыл бұрын
Power wores coming in?
@anthillmobstars
@anthillmobstars 4 жыл бұрын
That's probably a case of: "The unit isn't working. I don't know what this thing is it must be the problem. I'll just cut it out." People tend to blame the thing they understand the least. If you don't know how it works you can't be the one to condemn it.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Exactly. Well said
@Master-ls2op
@Master-ls2op 4 жыл бұрын
or it was not working. and they had the cant go over $800.00 so they did a job that would just pass it over to the next person.
@snipeguru1
@snipeguru1 4 жыл бұрын
Except.... the could have cut out the Headmaster and capped off the bypass. It would’ve actually worked, at least in the summer, and would’ve been easier and faster to do. They worked extra hard at fucking up.
@FireandFrostHVAC
@FireandFrostHVAC 4 жыл бұрын
Unreal. Given your time constraint NTE I felt your pain, no time or budget to repair it properly. I’m speechless too. Unreal.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. Several guys have suggested that. My response is, “not without an approval”. Because in 3 or 6 months that compressor takes a shit and it’s my fault. Lol. 😂😂
@jhp110
@jhp110 4 жыл бұрын
Good job I would suggest when you see a bad contactor to always check your low voltage to your coil on contactor I’ve seen the low voltage transformer putting out 24 volts then dropping to 14 volts burns the contacts if you don’t catch it you will eat up the new contactor good video
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Will.do. Thanks
@proc7867
@proc7867 4 жыл бұрын
You can’t fix stupid. Companies want their stuff working right, but don’t want to pay for it. Why can’t I go into their stores and take some drinks so I can stay hydrated and not pay for it? I would be arrested. They basically steal our services. However, I’m trying to learn more about the supermarket refrigeration systems, so these videos really help. Thank you!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Thank you. Yeah, this chain of gas stations are really strict on the money. So that’s why we leave it as is until it’s approved
@proc7867
@proc7867 4 жыл бұрын
Rookie Refrigeration that’s the only way to handle the company. If that’s what they want, that’s what they get. You have to get approval for everything big or small in order to cover yourself.
@grindstone5368
@grindstone5368 4 жыл бұрын
Is it the general manager placing the call and you gotta wait for them to get approval? I can see a customer doing that just because GM's are not exactly in mensa. Have a feeling it's to prevent stupid service calls from lower management.🤷‍♂️
@cranium33333
@cranium33333 4 жыл бұрын
I can’t stand 3rd party calls. But it’s the way our world is going so we have to adapt.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yes sir. Exactly
@Georges3DPrinters
@Georges3DPrinters 2 жыл бұрын
14:00 would be a quick thing to just pinch off by bypass tee's and brake the ends, at least it would work for time till pressure/ temp dropped.
@Georges3DPrinters
@Georges3DPrinters 2 жыл бұрын
But I would want to install headmaster if possible.
@rookierefrigeration4357
@rookierefrigeration4357 2 жыл бұрын
Agreed. But it was not work approved. So I couldn’t do anything.
@HermesVintage
@HermesVintage 4 жыл бұрын
Bro please keep us updated lol, this is too funny
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. Will do
@HVACRVIDEOS
@HVACRVIDEOS 4 жыл бұрын
Holy shit, that is epic
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lmao. I was in awe when I saw it.
@chap3845
@chap3845 4 жыл бұрын
My guess is it was the dead of winter and they found the "little mushroom thingy" dumping hot gas into the receiver and instead of adding the winter charge, they replaced them with copper... Probably ran ok when it was really cold out. Thing is he was probably really proud when he was done that he fixed it 🤣. Of course they never changed the driers either 🙄.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
That’s a very probable scenario. I could agree that happened. But damn. 😂😂
@chap3845
@chap3845 4 жыл бұрын
@@rookierefrigeration4357 yeah that was one of the funniest things I've seen on KZbin for refrigeration. I literally laughed out loud... I am currently doing a call on 15 doors of frozen food and it has the 7.5hp version of that unit, and it's low on gas with a warmish liquid line. I had to stick my head in there and make sure the head master bandit wasn't he too and just replaced it with copper. 😂
@jphvac5725
@jphvac5725 4 жыл бұрын
Wow. Whomever did that headmaster crap should be fined!! Gotta love fixing other people’s screwups!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. Yup.
@treverkirk8110
@treverkirk8110 4 жыл бұрын
That's crazy man. You probably could've pinched that line bypassing discharge gas into the receiver inlet as a temp solution.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. I “could have”. But this account is so unpredictable there’s no telling what will happen. So we don’t do anything without approval. That’s the way they want to play the game unfortunately
@timzeez525
@timzeez525 4 жыл бұрын
Lol ! I can’t believe someone thought that would work....
@mychoclabwinston
@mychoclabwinston 4 жыл бұрын
Why even go on a call like this? Total waste of time. I’ve had one before where they said I had to call if over 250, from a electronics store “chain brand” called them up and said sorry, call the next fool. This setup, lol, you need to remove the roof, to stop the hot air from circulating.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. I guess it just is that way 🤷‍♂️
@oliverbranson5565
@oliverbranson5565 4 жыл бұрын
Explains the burnt out contactors probably constantly slamming off on hpco. Good videos!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
That and possibly the fact that is extremely oversize it may be cycling wait too much too often
@chrissipple1018
@chrissipple1018 Жыл бұрын
Never worry about problems like that your hands are tied. Cheap ass company that gives you a cost limit like that. They can't spend the money because they have a house payment on Maui. Tell your boss to get rid of this customer.
@grindstone5368
@grindstone5368 4 жыл бұрын
Speechless. pretty much sums it up...
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup.
@kcomfortsystemshvac7060
@kcomfortsystemshvac7060 4 жыл бұрын
Good video,,,,discharge going strait,,,,into the receiver,, that the reason you have to high pressure,,
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. Very bad hacks out there
@j.r.1223
@j.r.1223 4 жыл бұрын
Yeah, but it works so good in the dead of winter!!!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. True
@miguelrojas3394
@miguelrojas3394 Жыл бұрын
They may be head master don't work,ohh no problem you don't need that shit.😂😂
@hvacrnortheastern2110
@hvacrnortheastern2110 4 жыл бұрын
In my area probably labor will eat into the $800 right now labor is $94 up to $145 per hour plus parts .You couldn't do the proper job for $800 plus parts .This is what happens when you have customers have a low ball contractor not doing proper job .
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. Exactly where were at!
@theduffster2581
@theduffster2581 4 жыл бұрын
I would of definitely pinched those lines off to at least to stop feeding hot gas Thru the receiver 👍🏻
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Agreed. But no. Not until this gets approved.
@theduffster2581
@theduffster2581 4 жыл бұрын
Don’t need approval to be proactive would of taken one minute 👍🏻 but I’m old school
@Luzt.
@Luzt. 4 жыл бұрын
@@rookierefrigeration4357 I agree. Technicians have no mandate of this kind or mission from God to do good. Customer runs the show. Learning takes place on both sides all the time. They will finally understand that if you want to pay below what market requires, you'll get sub-par service. Also, "you touched it you own it". If something went wrong you would be screwd. Good judgement, good rules. Thank you RR for your effort to help us learn.
@OcRefrig
@OcRefrig 4 жыл бұрын
@@Luzt. agreed. well said.
@BetoMota_
@BetoMota_ 4 жыл бұрын
Pinching the lines could have caused unforeseen issues, maybe causing units jot to temp si I agree with not doing it with a close NTE.
@superiorcomfortheatingairl3373
@superiorcomfortheatingairl3373 4 жыл бұрын
This is the first video I seen from you, I am very impressed
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Thank you I appreciate it. Give the channel a subscribe if you like the content
@MariosACandRefrigeration
@MariosACandRefrigeration 3 жыл бұрын
pinch off tool and a fan cycling switch will get you going.
@silktalk9104
@silktalk9104 3 жыл бұрын
Your at a Murphy’s I already know about there nte lol
@thernnhendog126
@thernnhendog126 Жыл бұрын
I like this guy and he's helping a lot with this interview I'm about to go to, but I'm sure you're not supposed to manually actuate contacts like that 🤨
@jakeholcombe4002
@jakeholcombe4002 4 жыл бұрын
😂
@akhermit5213
@akhermit5213 4 жыл бұрын
capacity control. They are using it to prevent fast pull down, thereby not stressing the walk in box or the bottles of product. Then they can sell slow cooled drinks. Customers will love it.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. Now that the cooler is running good, all the cases are working great
@terryj.macmullen9968
@terryj.macmullen9968 3 жыл бұрын
somebody didn t understand the function of a head master.unit probably under charged on start up.so the valve was bypassing,doing its job,and not being familiar with the head master thought the the bypss was a fault,and cut it out.should never have piped the unit in this fashion.compressor oil must be baked.suprised it still ran.have to leak test system with nitrogen and change oil i would think.they went to a lot of effort to to create a mess.
@terryj.macmullen9968
@terryj.macmullen9968 3 жыл бұрын
may have lost charge via relief valve.high pressure control should sht down compressor before relief valve opens.
@bryantylerservices
@bryantylerservices 4 жыл бұрын
Those coils inside look fairly new and condensing units.. Is there any warranty? Or liability on original installers you can go back to. Also, they need ( Murphy) to know on a hot day your never going to have cold product until there fixed correctly.. Unbelievable... Keep us posted.. Thx for your time brother. Bryan Tyler Refrigeration
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Only 2 years old. Probably out of warranty though
@bryantylerservices
@bryantylerservices 4 жыл бұрын
@@rookierefrigeration4357 Keep up the awesome videos bro.. Im going to subscribe.. Bryan Tyler Refrigeration
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Joseph Lopez thank you bro. I appreciate it
@jonathanschulz5841
@jonathanschulz5841 4 жыл бұрын
When in doubt, cut it out 😂
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Somebody took that motto to heart lol
@joshstevens9826
@joshstevens9826 4 жыл бұрын
I bet those compressors are screaming for mercy
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Josh Stevens they will die soon
@jimmyp5487
@jimmyp5487 4 жыл бұрын
WOW!! That’s ridiculous bro!! Someone forgot to pinch off the discharge line... pinch it off and add a fan cycle control. Ain’t no point of doing anything with extending that BS nte. Walk away and quote the shit outta them
@JCM2LA
@JCM2LA 4 жыл бұрын
Very good videos. Thanks
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Juan Carlos thank you. I appreciate you watching
@bryantylerservices
@bryantylerservices 4 жыл бұрын
By the way .. Thats the reason they are running undercharged... Best you can get out of it.. Bypassed.. Full charge to specs..will never work in current situation. So my gut ..low charge to get by.? Bryan Tyler .
@gurjeetsingh8323
@gurjeetsingh8323 4 жыл бұрын
Nice found. How you found Master board on Evap coil , Master board is you see Comp port , if this wire in , this mean this is master board.
@stormeagle28
@stormeagle28 3 жыл бұрын
Headmasters are cr*p, just stick to pressure controlled fans if you want no problems.
@rookierefrigeration4357
@rookierefrigeration4357 3 жыл бұрын
Depends on location
@gurjeetsingh8323
@gurjeetsingh8323 4 жыл бұрын
Nice found. Also you found Master board on Master board you see Comp port , if this wire in , this mean this is master board.
@joeydinner
@joeydinner 4 жыл бұрын
"That's messed up" lol
@danny337cmf
@danny337cmf 4 жыл бұрын
Fan cap is bad......but the fan is running!🤔🤔🤔🤔🤔
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
If it’s over the allowable rating, it’s bad. Not DEAD. But bad 👍🏽
@nitrofish1974
@nitrofish1974 2 жыл бұрын
Awesome video, lol 😆 looks like the butcher was there, unbelievable 😳 😆
@amadeusrocks4967
@amadeusrocks4967 4 жыл бұрын
some one was stupid on taking out a part
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup
@bjnopoli
@bjnopoli Жыл бұрын
I'm new to this but I guess a fan cycle control won't do the job if its plumbed for a headmaster? Strange that both were removed.
@RaNdUmGuY1
@RaNdUmGuY1 4 жыл бұрын
Those moonlighter’s really know how to make your day more interesting?😂
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lmao. Yup
@ares3914
@ares3914 4 жыл бұрын
Hacks at the best. "That's messed up " lmao
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol
@jeffreymurdock8366
@jeffreymurdock8366 4 жыл бұрын
They arent supposed to store inventory in the walkway of those coolers. they have a line they can't cross on the floor and usually have one on the wall they cant stack higher than.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. I wish
@Kilroy238_
@Kilroy238_ 4 жыл бұрын
"Supposed to" being the keywords there.
@terrytugwood7848
@terrytugwood7848 3 жыл бұрын
That’s unbelievable!!! I don’t know how those units run!!
@kevinbarker386
@kevinbarker386 4 жыл бұрын
Could you pinch off the bypass where the headmaster valve was originally? As a temp repair to get the unit on line until the head master gets installed? Really like your videos, I run commercial service calls in south florida.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yes I could have. But I didn’t. I won’t. I’m not going to do anything that puts us in a liability whatsoever. I’ll wait until the job is approved and then fix it. I mean, it’s probably been like this for 2 years. So...
@jonathanschulz5841
@jonathanschulz5841 4 жыл бұрын
Was that sightglass green (moisture)?
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
I don’t remember. Really didn’t think about anything once I saw the damage😂
@chicoabdallah3944
@chicoabdallah3944 4 жыл бұрын
Wow I'm believable Good job finding the problem
@edwardgaddis8333
@edwardgaddis8333 4 жыл бұрын
I'm pretty sure if a company put those kind of time restraints/billing cap on my company we'd tell them to take a hike. That's messed up. The job takes the time it takes.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. All we can do is submit a quote and wait for approval. 🤷🏽‍♂️
@edwardgaddis8333
@edwardgaddis8333 4 жыл бұрын
@@rookierefrigeration4357 Any hoo respect dude. Your out there killing it.
@gas_man1565
@gas_man1565 4 жыл бұрын
I dont disagree with you but sometimes those owners were taken advantage of, whats the big deal of getting an approval to get it repaired! sometimes its best, let them know that there is something seriously wrong and the only way to fix it, is to do what is needed. when quotes get sent and no repair is done by my company quote after quote.... then i will rub them off my customer list! i think thats more fair!
@joelg9804
@joelg9804 6 ай бұрын
What you shoul have done is write it all up first. Your diagnostic was not complete because you just asumed gas was flashing and thats all it was. Now you need a head master or fan cycling control. By the time you add your service trip, parts and labor you will way over $1500 including the head master. This one is on you. Sorry but don't be the guy blaming the previous guy. He just gave you the oportunity to shine and make money.
@richhpalchoudhary3230
@richhpalchoudhary3230 4 жыл бұрын
What hvac machanic very much demand in australia in salary
@brainfood_oo6186
@brainfood_oo6186 4 жыл бұрын
That’s crazy , I hope you didn’t do that lol 😂
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. Nope.
@Isidro_0401
@Isidro_0401 2 жыл бұрын
Sorry, about my english...why one of the unit didnt has the refrigerant complete?.,,,is there any refrigerant leak?,,,or it had incomplete refrigerant from the begining?
@snpdg1
@snpdg1 4 жыл бұрын
🙈🙈🙈
@ConservTab-sv3kx
@ConservTab-sv3kx 4 жыл бұрын
I hate this kind of stuff, but you have the solution
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
I’ll try to follow up with another video
@joshstevens9826
@joshstevens9826 4 жыл бұрын
Good way to put it. " This is astounding" hahahahaha
@Android_Warrior
@Android_Warrior 3 жыл бұрын
Any follow up to this one Rookie?
@rookierefrigeration4357
@rookierefrigeration4357 3 жыл бұрын
Nope. Never approved
@LC-sr9jf
@LC-sr9jf 4 жыл бұрын
Murphy it’s Walmart lol
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
It’s a stand alone Murphy. Corner gas station.
@billingtonjr15
@billingtonjr15 3 жыл бұрын
How did it ever work right???
@rookierefrigeration4357
@rookierefrigeration4357 3 жыл бұрын
Lol
@bwcnation
@bwcnation 7 ай бұрын
That looks like a newer install I'd say call the installers back warranty their work. Your over nte in an hr just finding the shit
@abazism
@abazism Жыл бұрын
You could off install fan cycling switch temporarily til they make up their mind
@BigHuff-sq9hb
@BigHuff-sq9hb 3 жыл бұрын
The NTE is what confuses me, I have no clue when I exceed 400 dollars. Which is the NTE at the main chain we service.
@markpayne6803
@markpayne6803 3 жыл бұрын
Hey Rookie some advice R U N
@rookierefrigeration4357
@rookierefrigeration4357 3 жыл бұрын
Lol. I’m glad we did
@xraybravo7180
@xraybravo7180 4 жыл бұрын
You made the right call at the right time, dont worry about what others says. TELL EM Xray is on my side !
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
😂. I appreciate it. Thanks for watching bud.
@nakiapringley5391
@nakiapringley5391 6 ай бұрын
Great video, bro. You thought of another name or you’re gonna keep the same name.?
@jacobcolby1423
@jacobcolby1423 4 жыл бұрын
Wow that’s crazy Hahaha amazing the stuff you see sometimes. Great vids btw been watching ur channel for a couple months now.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Thank you. I appreciate you. And this was a real crazy find. Lol
@OcRefrig
@OcRefrig 4 жыл бұрын
For the New Guys Out there --- ( Ftngot ) Each of Those Moh030's Will remove about 24,000 Btu's at a Plus 20 Suction on a 90 degree day. more on a cooler day and night. That cooler looks to be only about 22 feet long. So, One of those units will Do the JOb Probably on any Day cooler than 90 degree's. i Thought i did Over Kill ( LOL ) when i size a Little Heavy This is Where u Get into Trouble When u Oversize By Double without a Plan in Mind / setup and control properly. Excessive cycling could be a major problem here at Night & it looks like it is so by the signs of those contactors. Definately Need Short cycle Protection of some kind --- Be it a 5 Minute time delay on the contactors or Keep one Condensing unit off at Night or on a Temperature control so that if the ambient drops below 70 degree's that unit stays off. ( second or third idea is Best )
@SeanMackBuffaloStyle
@SeanMackBuffaloStyle 4 жыл бұрын
With glass door each 1500 btu load and pull down on product from delivery, probably why they went so heavy on btu
@pincheburro956
@pincheburro956 4 жыл бұрын
👍🏽💪🏼💪🏼
@DK_Journey
@DK_Journey 4 жыл бұрын
Great stuff dude, keep it up!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Thanks Dustin.
@CHOMAHOMA
@CHOMAHOMA 2 жыл бұрын
Hahahahaha. Primo. I am new in the tarde and I wouldn't do that ever.
@hrdworkin7633
@hrdworkin7633 4 жыл бұрын
To quote Forest Gump....'Stupid is as stupid does.'
@kevinpoore5626
@kevinpoore5626 3 жыл бұрын
Stupid is as stupid does and that looks pretty dang stupid LOL
@yomomma9070
@yomomma9070 3 жыл бұрын
There are words for this it's called hack job.
@SombraLocs
@SombraLocs 4 жыл бұрын
Great video man! I’m always learning something from your videos!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Thank you for watching bro. I appreciate it.
@josephmorales3728
@josephmorales3728 4 жыл бұрын
Que pasa man wow no headmaster This is not good . I am in Florida
@HVACRDUDE
@HVACRDUDE 4 жыл бұрын
ALL CAPS DISCHARGE TO THE START WINDING!!!!!!
@HVACRDUDE
@HVACRDUDE 4 жыл бұрын
You lost me the second you just tried to discharge a capacitor as a REFRIGERATION TECH! 😑😑🤨
@rocker8692
@rocker8692 Жыл бұрын
$800 an hour,thats pretty good money
@eliojeda3065
@eliojeda3065 4 жыл бұрын
Lol I think the previous tech should take the name rookie.
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. Thanks. I’m only an ok tech. Lol. I take pride in reading and learning
@TonyHoanz-vc2pq
@TonyHoanz-vc2pq 6 ай бұрын
Thanks for sharing. Tony from Houston
@ft668615
@ft668615 4 жыл бұрын
Wow ! Remove the head master !!! Easy call !
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. Yup. Hopefully I can install them if the quote gets approved
@andreware7536
@andreware7536 4 жыл бұрын
Love the videos bro! Keep up the great work! ✊🏾✊🏾
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Thanks
@UltraHydrophobiccoat
@UltraHydrophobiccoat 4 жыл бұрын
What’s the copper size of the discharge line ? What’s the correct way to get rid of the headmaster? Thank you
@Mac_Kraken
@Mac_Kraken 2 жыл бұрын
Wow that brazing is awful lol
@johndeerefan725
@johndeerefan725 3 жыл бұрын
Was the caution tape to block the product glass doors for the WIC to keep the product cool?
@redeye2629
@redeye2629 4 жыл бұрын
That’s not the first time I’ve seen this lmao
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Chuck Urgitus that’s pretty sad. Lol
@redeye2629
@redeye2629 4 жыл бұрын
Rookie Refrigeration I know tell me about it. Although I’ve never came across two in a row like you did. That’s one on me lol
@sivalley
@sivalley 4 жыл бұрын
Those missing HPRs explain why the contactors were pitted to hell. That's some Unqualified Personnel special there. (Edit for grammar)
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. That’s what I’m thinking. Too many cycles. And I wonder how the compressor have handled it.
@hvactechpr7872
@hvactechpr7872 4 жыл бұрын
Prolly another maintenance guy messing with reefer that's a no no
@sivalley
@sivalley 4 жыл бұрын
@@rookierefrigeration4357 $20 says the start relays are cooked and that you have organic acids in the system from hot windings on the poor compressors.
@karizmatic5
@karizmatic5 8 ай бұрын
That's messed up.
@SeanMackBuffaloStyle
@SeanMackBuffaloStyle 4 жыл бұрын
Normal day. Haha Those electronic txv are rated up to 6 tons, so every drop of liquid is probably getting into each coil. I bet each valv is maxed out at 249 steps. If it was a mechanical txv, no way it would be pulling down. Hilarious, their stupid not to exceed probably fucked them. Nobody can do a full checkout and repair for 500 or even 800 on two units. Nice job
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
👍🏽👍🏽👍🏽yup.
@josephmorales3728
@josephmorales3728 4 жыл бұрын
Not to install tow headmaster for 800 end the contactor end the capacitor .
@ConservTab-sv3kx
@ConservTab-sv3kx 4 жыл бұрын
Time for a QUOTE
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Yup. Quoted it away.
@chriscordasco5449
@chriscordasco5449 4 жыл бұрын
pinch it off ! LOL
@redneckways1617
@redneckways1617 7 ай бұрын
Wow…the could have at least straight piped it then added fan cycle switches
@mranonymous2082
@mranonymous2082 3 жыл бұрын
The old guys I work with cut out headmasters all the time
@chasemeshell4114
@chasemeshell4114 2 жыл бұрын
how do you not have contactors and 404a on your truck. lol
@rookierefrigeration4357
@rookierefrigeration4357 2 жыл бұрын
It happens when you are very busy.
@picklerix6162
@picklerix6162 4 жыл бұрын
Never seen that before. LOL!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
Lol. That makes 2 of us!!!
HVAC Refrigeration:  Walk In Cooler down and wired incorrectly.
19:14
Rookie Refrigeration
Рет қаралды 31 М.
HVAC REFRIGERATION:  Dual Temp Case running warm, Rack Refrigeration.
15:59
Rookie Refrigeration
Рет қаралды 15 М.
iPhone or Chocolate??
00:16
Hungry FAM
Рет қаралды 46 МЛН
An Unknown Ending💪
00:49
ISSEI / いっせい
Рет қаралды 57 МЛН
Walk-In Cooler Warm and Compressor Is HOT
12:26
HVACR Survival
Рет қаралды 15 М.
Walk in cooler not cooling
13:23
Curious HVAC Guy
Рет қаралды 23 М.
Another Callback! | Intelligen by Heatcraft Troubleshooting | HVACR
26:16
Why is the walk-in cooler icing up
44:47
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 22 М.
Walk in cooler not cooling
13:21
Curious HVAC Guy
Рет қаралды 19 М.
Walk In Freezer Running Warm:  Why headmasters are cool.
11:24
Rookie Refrigeration
Рет қаралды 10 М.
WALK IN FREEZER DEFROST ISSUE
34:29
HVACR VIDEOS
Рет қаралды 105 М.
Walk in Cooler is not Cooling. Rebuilding a TXV.
17:16
REFRIGERATION KITCHEN TECH
Рет қаралды 15 М.
Refrigeration: Low Pressure Control As Temp Control
25:22
Christopher Molnar
Рет қаралды 95 М.
iPhone or Chocolate??
00:16
Hungry FAM
Рет қаралды 46 МЛН