HVAC VFD Commissioning & Configurations

  Рет қаралды 8,458

HVACTIME

HVACTIME

Күн бұрын

Пікірлер: 10
@LuisRamos-rw5yu
@LuisRamos-rw5yu 2 жыл бұрын
You the man thanks for taking time to do vid
@spikester
@spikester 2 жыл бұрын
Large industrial sized LED drivers capable of dimming also work with a 0-10V line for the dimming control input, also its an isolated input. That makes much sense that the principles are similar.
@lee-johnson
@lee-johnson 2 жыл бұрын
I have a bunch of experience with many drives , but I have an issue with Eaton drives in that they won't restart after a power outage. They go into alarm. I've heard there is a parameter that will fix this and have it auto restart. Would you happen to know? Thanks for the helpful videos.
@HVACTIME
@HVACTIME 2 жыл бұрын
I wish I knew
@Dmc963
@Dmc963 Жыл бұрын
So there’s a setting in the VFD that says accelerate and decelerate check to make sure they’re not set to 30 seconds because what ends up happening is it’ll start up too fast and trip out so set them to 60 seconds both accelerate and decelerate
@Dmc963
@Dmc963 Жыл бұрын
Most automation set to 60 secs …At least in my area (siemens)
@Ak3rn0
@Ak3rn0 Жыл бұрын
If I got more info about the drive, I can verify which exact parameter it is. What I’ve found is: Model 9000X: menu M1, G1.8 somewhere in there PowerXL DC1: Parameter P-30: Start Mode should be set to something between 1-6, depending on how many attempts the drive should make. “Auto-0” is infinite, “Auto-1” through to “Auto-5” are the number of attempts. Model M Max P6.13 should be set to 1 for auto restart All these parameters are for auto restart after a fault. Yaskawa and Siemens have a setting where they require the signal to go off, then on, in order to restart the drive after a power outage. They essentially consider an ON signal received before the drive powers on to need to be reconfirmed. I don’t know if Eaton also does this, and I don’t know where that setting might be.
@Andrea-pz5re
@Andrea-pz5re 3 ай бұрын
we have got a couple of brand new ACH550s in stock if anyone is looking for one..
@HVACR559
@HVACR559 Жыл бұрын
I can just imagine what a nightmare it will be if a TRANE has modbus communication with the VFD and the VFD dies. Then it doesn't want to run bypassed because it can't talk to the drive.
3 Greasing Practices, Chiller Techs Opinion
19:05
HVACTIME
Рет қаралды 1 М.
HVAC VFD Accel/Decel Time Commisioning
12:05
HVACTIME
Рет қаралды 988
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН
СИНИЙ ИНЕЙ УЖЕ ВЫШЕЛ!❄️
01:01
DO$HIK
Рет қаралды 3,3 МЛН
Carrier RTU - VFD & Fan Board Operation (ACS320 - Schematic)
6:01
Customer Assurance FL
Рет қаралды 15 М.
What does Chiller Load mean?
8:04
HVACTIME
Рет қаралды 959
How to Prepare for an HVAC Interview
3:02
HVACR Career Connect NY
Рет қаралды 2,5 М.
HVAC Cooling Tower Wiring Short Troubleshoot
14:02
HVACTIME
Рет қаралды 1,2 М.
Criminals in HVAC....
4:47
HVACTIME
Рет қаралды 1,5 М.
Chiller Tech Basic Tools - Chiller Academy
49:01
HVACTIME
Рет қаралды 1,9 М.
Know Screw Compressors Staging - Chiller Academy
29:12
HVACTIME
Рет қаралды 1,5 М.
Chiller Metering Device Main Function - Chiller Academy
9:08
HVACTIME
Рет қаралды 1,1 М.
Future of VRF Chillers - Chiller Academy
18:38
HVACTIME
Рет қаралды 1,3 М.
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН