HVAC: York RTU Not Cooling Properly (York RTU NIGHTMARE Not Cooling) Frozen Evaporator Coil & More

  Рет қаралды 7,016

Jumper man Tech

Jumper man Tech

Күн бұрын

Пікірлер: 52
@Matthew-vl5iv
@Matthew-vl5iv 4 ай бұрын
And they say maintenance is a scam! Keep up the good work brother 👍
@ebfsystem
@ebfsystem 4 ай бұрын
I usually remove the filters out of the unit with the power off,esier and all that crap don't fly all over the coil. Great video!
@Paul-IE-Repairs
@Paul-IE-Repairs 4 ай бұрын
i usually check the filters and airflow before checking charge on a frozen unit, or quoting the customer an evaporator change as well.
@woodmasterguy
@woodmasterguy 4 ай бұрын
JMT, congrats on the 100k subs. Great video as usual.
@Eddy63
@Eddy63 4 ай бұрын
Nice job & nice NY skyline ... Thx
@thesilentonevictor
@thesilentonevictor 4 ай бұрын
Jmt is the man for the job
@justinhayward5027
@justinhayward5027 4 ай бұрын
Yo yo! Helping out algorithm! Good stuff!
@genewheeler6320
@genewheeler6320 4 ай бұрын
I love that view
@Hvacsteve69
@Hvacsteve69 4 ай бұрын
I have the same pressure washer for cleaning coils. Idk about using the turbo tip on coils without damaging them but to each there own. Great video
@zekenzy6486
@zekenzy6486 4 ай бұрын
Great video. Thank you for sharing. Have a nice weekend
@stevencossaboon3237
@stevencossaboon3237 4 ай бұрын
Nice work Jumper Man.
@MrAfdasdfa
@MrAfdasdfa 4 ай бұрын
Yo who else works on these bigass rooftop units. I'm learning a ton and KZbin University is the best thing next to sliced bread
@CZDigger
@CZDigger 4 ай бұрын
Nice vid. One thing I never do is use a brush on the coils. Simply I am not breathing that dust. Cannot be good for you and if your using coil cleaner, no need to brush. I can see in certain circumstances, but I have never run into a situation where coil cleaner did not get the coils clean with the need to brush the coil. Enjoyed the vid.
@genewheeler6320
@genewheeler6320 4 ай бұрын
Great job bro.t shirts t shirts..lol
@alexz7735
@alexz7735 4 ай бұрын
It’s economizing and mechanically cooling. Lol. It all comes down to maintenance. I don’t know if you noticed but the outside air dampers are missing the metal mesh screen to keep the bugs out.
@Gwlyddyn
@Gwlyddyn 4 ай бұрын
When the janitorial staff is busy having coffee.
@briancarlisi2224
@briancarlisi2224 4 ай бұрын
ABC… airflow before charging
@jasonjohnsonHVAC
@jasonjohnsonHVAC 4 ай бұрын
Is that coil cleaner microchannel safe. I wouldn't think so. The refrigeration Technologies yellow cleaner is microchannel safe....I tend to only use chemicals as a last resort on microchannel. Usually it's just water only.
@avi-tar2827
@avi-tar2827 4 ай бұрын
Dawn dish soap (diluted with water) in a foam cannon works wonders, too, if you're lugging a pressure washer to the job site. The main thing is to break up the sap, oils and bug guts that get on the coils.
@vincentzenuh978
@vincentzenuh978 4 ай бұрын
i thought you union guys were a step up on service techs
@jls1259
@jls1259 4 ай бұрын
where can i get that little air gun
@mexedwin.892
@mexedwin.892 4 ай бұрын
I’ve seen it on TikTok shop
@nicolerennie
@nicolerennie 4 ай бұрын
unfortunate for sure… at least the views make up for the mess
@ronnym1977
@ronnym1977 4 ай бұрын
Hey JMT! I watch all of your videos and I really enjoy them all. I have a few HVAC questions. I really do not know this, and I am not trying to trip you up. Why is a p-trap used on condensation waste pipes? Will the condensation waste not flow out of a straight waste line? Is there an issue with odor?
@brokenhalo22
@brokenhalo22 4 ай бұрын
You need to have a trap with water in it to keep the unit from pulling outside air into the cabinet via the drain line. I've seen units where the trap was dry, air was being sucked in through the drain, and the cabinet filled up with condensate and started leaking out in other spots, kind of like in this video where condensate was leaking out of the side of the unit. As soon as the unit was shut off, it lost that suction vacuum, and the condensate flowed out of the drain line like it was supposed to.
@ronnym1977
@ronnym1977 4 ай бұрын
Oh! Okay, now I know. Thank you so much for answering my question!
@ausseamore8386
@ausseamore8386 4 ай бұрын
good job partner
@Clos_97
@Clos_97 4 ай бұрын
I saw a comment already abut the mini air Gun I’ve been looking for the air gun in Amazon I can’t find it, where you got it
@neilcvids2583
@neilcvids2583 4 ай бұрын
weren't you just on this unit a month ago? didn't you change filters then ?
@SDPP992
@SDPP992 4 ай бұрын
Can imagine what the ductwork looks like on the inside lol
@AFpaleoCon
@AFpaleoCon 4 ай бұрын
What was the year on the dollar!?
@DanielHernandez-tp2tm
@DanielHernandez-tp2tm 4 ай бұрын
What area is that in? Beautiful sites. I believe y'all all the borrows?
@Teaching-wi5gd
@Teaching-wi5gd 4 ай бұрын
You need to lock into getting some trubul vacuum hose 3/4" ID 16 cfm of vacuum per hour through the hose it will cut your vacuum time by 80% or more TruTech Tools sell them
@rightconditions2010
@rightconditions2010 4 ай бұрын
Brother, do you use social media for work, too?
@larryl2459
@larryl2459 4 ай бұрын
Those people killed that unit.
@polishsharpshooter2876
@polishsharpshooter2876 4 ай бұрын
The pink stuff on micro channel coils? You will destroy them.
@vincentzenuh978
@vincentzenuh978 4 ай бұрын
did you spray that crap on the evap coil previously?
@pualruiz
@pualruiz 4 ай бұрын
Crazy that I can see your videos and be like peed on that roof , peed on that roof and peed on that roof
@arthouston7361
@arthouston7361 4 ай бұрын
Hmmm. I'll guess. Somewhere around 14th street?
@oldmetalguy4577
@oldmetalguy4577 4 ай бұрын
NBC coils...never been cleaned
@genewheeler6320
@genewheeler6320 4 ай бұрын
Aaaaasasa my worst pet pieve, how do you not no to change filter. Filters are the lungs of ac units
@abdullah_q8171
@abdullah_q8171 4 ай бұрын
York design is difficult to maintenance.
@TylerDurden0331
@TylerDurden0331 4 ай бұрын
What means tatoo on Your right arm?
@ILoveKittys78
@ILoveKittys78 4 ай бұрын
😻💚💜💚
@richardc1983
@richardc1983 4 ай бұрын
My question for you here as you are always back at this hotel. Is there not even a basic pre planned maintenance schedule in place or is everything run to fail. I get things like fan motors etc replacing when they fail but for filters to be in the state they are.
@jesseh5554
@jesseh5554 4 ай бұрын
Best practice is to NOT use cleaner on micro channel coils
@RodgerMudd
@RodgerMudd 4 ай бұрын
I tell people all the time if you knew what the AC system looking like in some places you would never go in. Restaurant ice makers are the worst, I have seen some with new life forms evolving in them. The microchannel coils are crap. York use to make good units.
@knockitofff
@knockitofff 4 ай бұрын
top off the circuit that's running, it's a split evaporator, they're separate circuits
@mannyfresh8504
@mannyfresh8504 4 ай бұрын
That filter…. 😣
@David-ml1be
@David-ml1be 4 ай бұрын
York RTUs are dogshit in all aspects
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
BAYGUYSTAN | 1 СЕРИЯ | bayGUYS
36:55
bayGUYS
Рет қаралды 1,9 МЛН
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
How To Properly Clean An AC Evaporator Coil & Save HUNDREDS!
15:33
The DIY HVAC Guy
Рет қаралды 1,4 МЛН
Carrier rtu AC not cooling
18:08
Curious HVAC Guy
Рет қаралды 21 М.
NO GOOD DEED GOES UNPUNISHED
46:48
HVACR VIDEOS
Рет қаралды 95 М.
HVAC Troubleshooting Part 1
1:10:37
HVAC School
Рет қаралды 23 М.