THEY SAID HURRY EVERY AC IS DOWN

  Рет қаралды 208,622

HVACR VIDEOS

HVACR VIDEOS

2 жыл бұрын

Don't you just love the every ac is down calls.... Most of the time its just one of two but I still laugh when they say that.
HVACR TOOLS CHANNEL- / @hvacrtools
HVACR VIDEOS NEW MERCH WEBSITE - www.hvacrvideos.com
Please consider supporting my channel by
Becoming a Patreon member - Patreon / hvacrvideos
Becoming a KZbin channel member / @hvacrvideos
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch www.hvacrvideos.com
HVAC OVERTIME CHANNEL LINK - / hvacovertime
Social Media
Facebook / hvacr-videos. .
Instagram / hvacrvideos
For any inquiries please contact me at chris@hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752

Пікірлер: 253
@jordanhenshaw
@jordanhenshaw Жыл бұрын
I really like how all the youtube channels teaching this trade are all interconnected and all agree on the important stuff. This channel, Ty, HVAC School, that compressor guy, all these people reference each other and respect each other. So nice to see. In other trades, this channel badmouths that channel, the other channel says this channel is giving terrible advice, and it goes on and on and on so that newcomers like myself don't know who to listen to.
@HVACRVIDEOS
@HVACRVIDEOS Жыл бұрын
Yeah we have a great community, thanks so much for watching and for the nice words
@Flameancer
@Flameancer 2 жыл бұрын
Idk how I got to an HVAC repair channel, but this was one of the most interesting videos I’ve seen on YT.
@tbelding
@tbelding 2 жыл бұрын
I have a customer with a manager I call Chicken Little. Any time there's an issue, the sky is falling. At one point, she told me everyone in her department was having issues. I then spent three hours troubleshooting the common server/network points, not finding anything (while fielding calls from the woman). I then finally called another person in the department to get more information, and found out _only one person was having problems_. Apparently, because that one woman had a bad network cable, the entire department was down. I no longer believe anything she says other than as a starting point to talk to other people to find the problem. I get chewed out by the owner, and I chew him out for listening to her at all. She's really good at the business, but she's absolutely terrible with tech. Just like this - you can't fix the problem until you actually know what the problem might be.
@fitybux4664
@fitybux4664 2 жыл бұрын
LOL. I like it. Triage against crazy people.
@Sonyboj
@Sonyboj Жыл бұрын
I have no idea what is happening in the video but it REALLY reminds me of IT troubleshooting. OSI model, check layer 1 first, then check layer 8 :)
@WHPL4SH
@WHPL4SH 2 жыл бұрын
Yo man, you have been a true mentor to me and I appreciate it. I don't do AC work normally but wanted to tell you that I really appreciate you. I have a hard time keeping up with my own work and billing but watching you run a company with techs and still finding time to make these videos to help out others is truly inspiring. Thanks brother.
@godbluffvdgg
@godbluffvdgg 2 жыл бұрын
God bless the inventors of AC and god bless those that come to fix them or install them...I'm a General Contractor, I've been dealing with them for 30 years...This stuff here is heavy duty, and The guys that repair these systems are a dying breed, literally, we lost 10000 years of experience in the last 20 years... The guys that know what they're doing, like You guys, are true mechanics.
@MaDrung
@MaDrung Жыл бұрын
Oh geez, you're overselling it.
@godbluffvdgg
@godbluffvdgg Жыл бұрын
@@MaDrung You're underselling it!
@Sadsoul38
@Sadsoul38 2 жыл бұрын
I been doing this trade 16 years and when I wanna learn more I watch your channel I learned so much about RTU's and R290 systems from you watching you greatly appreciated keep up the good videos
@PeterParker-tb7ce
@PeterParker-tb7ce 2 жыл бұрын
FYI, You need to watch out for when using 407C. Most of the time when charging or evacuating a system with 407c, it creates a static charge on the hose. We have fried a number of scales because or that. So we always have a jumper wire across the hose. For context, we build custom units. So sometimes the system may be disconnected from ground and power when we do this. Also 407C can give a false short to ground on the compressor after vacuum and charge. When a new system comes to me for test. I have to run the compressor for a few seconds or I will fail our megger test every single time. I even have to bump the compressor, if it sits for a day or two sometimes. These are brand new Copland compressors.
@HVACRVIDEOS
@HVACRVIDEOS 2 жыл бұрын
Hey bud that is some really interesting info... Would you mind emailing me I'd love to talk more about it!! Hvacrvideos@gmail.com
@MegaDysart
@MegaDysart Жыл бұрын
Why are you megging brand new compressors? How can static electricity travel across a rubber hose and fry a scale? I've been searching the internet for like 25 minutes trying to find anything related to 407c causing static electricity or affecting winding insulation and nothing is coming up...
@PeterParker-tb7ce
@PeterParker-tb7ce Жыл бұрын
@@MegaDysart We meg the system per customer requirement. We build custom system and on some units Megging is required during testing. I don't know why the hoses build up charge but they do. I myself have been shocked by one and fried the scale in the process. We use Yellow Jacket Plus II hoses (usually the Ball valve version). The scales that we uses are mostly CPS's. I believe the CC220 model. We use Copland compressors. I don't remember if I tested compressor by itself since I test the whole 240 VAC system at once per test procedure. If I don't bump the Compressor it takes the test value out of range. We usually use an Appion G5twin to move the Refrigerant. We started to use R407C in place of R22 15+ years ago. Since it was a direct replacement for R22 in our systems. We were already using POE oil in our systems. Engineering decided on R407C since it was closes to R22 performance wise for our products ambient operation range. At least that's what I have been told. As to why we get a static charge, we never really looked into it. I'm just passing on what we have seen. At first we though we had defective scales. That was until someone got shocked. The only thing I can think of is the hose is acting like a ballon when you rub it on your head. All I know is that if we put a jumper wire connect to both brass/copper end of the hose, no problem. Really haven't tried it with other Refrigerants. Why risk frying more scales. We mostly use R407C like 90%, some R410a, little R134a and some other Refrigerants. It's just standard procedure for us now to use a jumper wire.
@MegaDysart
@MegaDysart Жыл бұрын
​@@PeterParker-tb7ce that's crazy as hell. Thanks for the info bud. Never ever would've thought that would be possible.
@VEC7ORlt
@VEC7ORlt 2 жыл бұрын
As an EE it baffles me that all the boards, connectors, etc etc are basically open to the elements in all these units.
@CallsignMayhem
@CallsignMayhem 2 жыл бұрын
#15 rosebud is an "all-in-one" tip. I use that thing from 1/4" to 1-1/8". Love that thing.
@markbeiser
@markbeiser 2 жыл бұрын
I use a rosebud tip for everything that doesn't require pinpoint heat.
@brianmillion-osborne6747
@brianmillion-osborne6747 2 жыл бұрын
I believe the leak on the compressor isn’t a soft plug. I believe it is a weld where the windings are held in place there should be 3 of them
@achillies40
@achillies40 2 жыл бұрын
I like how you do diagnostics. It seems like a methodical and logical process. (I am an industrial electrician in Australia) The only comment I have is that almost every AC, generator or any other machine I have seen from the USA very rarely has neat wiring. In many of the machines I have worked on, even when brand new, the wiring looks like a bird's nest. I like having neat control wiring but I am not over the top with it. Machines from the US, much like the AC units we saw in this video, look like they have had a school kid on work experience wiring up the machines. Rarely did I see cable numbering either. Great video though. Thanks for sharing.
@seagie382
@seagie382 Жыл бұрын
Maybe its a case of "is it really messy if I work on the exact same bird's nest every time?"
@brake_4_cake
@brake_4_cake Жыл бұрын
The American mindset is that specialised skills require specialised education, which they don't do. It's the same reason for the massive gaps around toilet stalls there, they want something that can be thrown together easily by someone with little or no experience.
@scotttjernagel4616
@scotttjernagel4616 2 жыл бұрын
Wanted to say thank you for the videos. They are showing me better and more efficient ways to troubleshoot and diagnose issues.
@peterhodgkins6985
@peterhodgkins6985 2 жыл бұрын
Thanks for your comments on 407C! The only reason I got my federal certs is that I'm an old retired oil/gas/power gen guy, and my local company put the double-rectified screws to me on a repair of one of my residential systems. They lost my R22 charge cutting out the drier, and replaced it with R407C and didn't do ANYTHING about oil. Needless to say I had a mess on my hands. The thing worked, but the evaporator was always flooded with oil and it really killed the heat transfer properties. A lot of money for poor performance. I decided after not getting any satisfaction from them that I was better off just getting certified and buying my own equipment and doing it myself. I've learned a TON of stuff from real pros like you and a handful of others. I wasn't willing to risk my dwindling supply of R22 on the system with R407C in it, (15.5 lbs), so I converted it to R458A which works fine with mineral oil. I added a TXV and the thing works better than it ever has now. The only problem I've seen with these blends is that the wide condensing spectrum (glide) can trick a fella into overcharging if he's relying on a sight glass out of the condenser as an indicator. You could be on target with your superheat and still not have a clear sight glass. There ain't any good shortcuts. I've always adopted the mantra "Do it right as you can the first time around, or you'll end up doing it at least twice!".
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
Thats why i shoort for the mid point in blends.
@epiphany6
@epiphany6 2 жыл бұрын
Comfort cooling should be subcooling, not sight glass based for TXV - that'll result in far more accurate performance.
@throttlebottle5906
@throttlebottle5906 2 жыл бұрын
"third times the charm" when all else fails. lol
@ArtStoneUS
@ArtStoneUS 2 жыл бұрын
What's the current status of the ozone hole?
@user-lb1ks2ip8q
@user-lb1ks2ip8q Жыл бұрын
Super professional. What a treat watching an expert in his craft.. Super professional. What a treat watching an expert in his craft..
@PhillipFrischman-vo8gm
@PhillipFrischman-vo8gm 3 күн бұрын
You're right about the refrigerator and s*** I agree with you 100%
@oxnardshores8058
@oxnardshores8058 2 жыл бұрын
I had found a leak on a Carlyle Comp when I started. Also i recently did a evap and dual condenser cleaning on an old ICP 5 ton pulled the top off they way you showed us in all your videos, thanks again Chris.
@ICountFrom0
@ICountFrom0 2 жыл бұрын
Customer is very lucky today I suspect. Everything was down, but you know the systems well enough, and the care you take to investigate everything lets you get things up and running .. well, limping... Further, even the worst problems are the least bad versions of them. Saved from tainted oil by the last whisp of pressure in the system, perhaps even a single week latter it would have not had that bit of grace.
@paulcrandall2534
@paulcrandall2534 2 жыл бұрын
Back in 2011-12, my local supply house was starting to really push MO-99 as a replacement. We were working on a 120 ton AAON unit. It had 4 cooling stages with 8 Copeland compressors (4 twins). All four compressors had finally died in 2 of the stages. We put 4 brand new Copelands back into the unit and, with the Copeland rep's blessing, we put in MO-99 as a replacement because the customer wanted to save money on refrigerant. We get everything in, all compressors and all stages are running like a champ, and went home for the night. When we went back the next morning, the same two stages we replaced were down again and all 4 compressors were drawing LRA. We couldn't figure it out and couldn't get those compressors started again. We had our supply house and local Copeland representative come out and diagnose what happened. They checked if our installation was correct(it obviously was, I'm only a hack when I need to be lol). They analyzed the refrigerant and oil for contamination. They checked everything. Went through the entire unit with a fine tooth comb. They found that the MO-99 essentially washed the oil out of the compressors, but it wasn't carrying the oil back and all 4 of them seized up overnight. All of the oil was being trapped in the evaporator. It had to do with the way the unit was piped from the factory. It worked fine for r-22, but not for MO-99. Copeland determined that due to the sheer size of this unit, there needed to be more traps in the circuit to allow the MO-99 to bring the oil back. Copeland ended up giving us another 4 brand new compressors to install, but they wanted us to put r-22 back in the system in order to warranty them. I'm sure an oil separator and/or adding some traps along the circuit would've worked, but neither I nor Copeland trusted MO-99 in this system. Don't even get me started about using MO-99 in medium or low temp systems. It seems to work ok in smaller package rtu's (like 20 ton or less) and split systems(depending on lineset elevation and trapping). I just try to avoid using it altogether though. It's a terrible refrigerant.
@olee2020
@olee2020 2 жыл бұрын
Thank you for sharing your real experience.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
I can't stand MO99 for this reason. Ive seen it kill compressors as well
@Rob0243
@Rob0243 2 жыл бұрын
We recently acquired a 9 story with 60 to 100 ton splits. Converted to MO-99 after research and acknowledgement that previous contractor was changing out several 06e’s a month though trapped all the way to first. We found two major factors and have had many less failures. One must use POE. Though supply houses will tell you it will work mineral and it will on same level installations. Mineral will not bond enough to carry in extensive lift situations. Two. The had installed EXV’s which did not have a dedicated MO99 scale and they had left them set on R22 which works if you are using the saturated scale liquid but you do not on blends with glides. Did comparisons of all available scales and 438a came with in one degree both saturated vapor and saturated liquid. On r22 it would go south of 4 degrees superheat on load up. Once scale change it had a smooth 18 degrees even when switching between load and unload. Biggest thing for compressor failure on MO99 was oil return on multilevel. Viscosity will not lift far with mineral oil.
@tonnentonie2767
@tonnentonie2767 Жыл бұрын
I am an IT guy and didn't understand a word but the world of AC units is fascinating, working on electronics is so cool. I've started to repair my house appliances and feel like a god after I said FU to our throwaway society.
@mattluongo7763
@mattluongo7763 2 жыл бұрын
I once had an old copland scroll leak in the same exact spot.. But only once in years of doing this trade. The company I work for still uses R22 but has also been using 407c for a few years. It works good on straight ACs but has problems with heat pumps sometimes. In the last year we start using Bluon TDX20 (R458A) and personally I really like it alot. Would recommend it to anyone looking for R22 replacement.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
If anyone doesn't already know. For a Copeland scroll AE 1294 bulletin gives you information on what they state is acceptable megg test values. Chris you should try using the PI ( Polarization Index ) DAR ( Dielectric Asorbtion Ratio ) test when megging. PI uses readings at 1 and 10 minutes and uses a scale to determine the quality of insulation. DAR is a 60 second test, with readings at 30 and 60 seconds with a scale as well. Your megger i believe has that function. Just FYI for my fellow HVAC brethren
@HVACRVIDEOS
@HVACRVIDEOS 2 жыл бұрын
Thanks bud!
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
@@HVACRVIDEOS 🤘🤘🤘🤘
@wd8557
@wd8557 2 жыл бұрын
I have the Megger 420 / 2 that does the Dar / PI test. That test make's a big difference. I usually only use it on big shit like chiller's. However your Fluke is perfect for what you are doing.
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 жыл бұрын
@@wd8557 myself as well. Im commercial/ industrial and thats where i first heard of it. Then did some reading and have been using ever since
@wd8557
@wd8557 2 жыл бұрын
@@jasonjohnsonHVAC Don't get me wrong the fluke will be 99.9 percent right on the small compressors he works on. But the end all of day is a megger that can run test. Two different stories.
@elBusDriverKC
@elBusDriverKC 2 жыл бұрын
Whenever I’m on a site with many many down units, I always check the fire alarm first to make sure they aren’t all locked out because of a silenced fire alarm.
@darrellfranklin2646
@darrellfranklin2646 2 жыл бұрын
Those are plug welds holding the scroll pump assembly in the can. I used to work in the facility that produced them.
@richh5392
@richh5392 Жыл бұрын
I don’t even work on this stuff and you had me watching at 11 pm
@winstonwright3613
@winstonwright3613 2 жыл бұрын
Nice Video. Nice to see you using 407C, as that's also what I have chosen as my replacement for R-22. It seems to work well. And the whole "Glide" thing that has everyone so scared is easy to work with once you understand it. What I'm worried about is performance, and 407C does it. It works well, and gives efficient cooling. No headaches.
@SuperBrainAK
@SuperBrainAK 2 жыл бұрын
Yep when stuff hits the fan there is nothing better than a calm and collected methodical technician. You wont get it fixed any faster by panicking.
@zjs3157
@zjs3157 2 жыл бұрын
i am at the point that i literally watch all of your videos like there a soap opera lol. every new epsiode is the same feeling as a new episode of game of thrones.
@thewicksj
@thewicksj 2 жыл бұрын
Chris I got a chance to watch 2 guys change 2 condenser fan motors on a system right outside my hotel window.
@Tinytraveler
@Tinytraveler Жыл бұрын
I don't know how I got here, but I actually enjoyed this whole video! Keep up the great work!
@djhaloeight
@djhaloeight Жыл бұрын
Super professional. What a treat watching an expert in his craft.
@marshallh3637
@marshallh3637 2 жыл бұрын
I work in an office and stumbled on your videos about a year ago. I have developed great respect for your trade after watching your videos. Keep them coming
@LazyLifeIFreak
@LazyLifeIFreak 2 жыл бұрын
Had this video with dinner, paprika chicken breast with corn on the cob and a tomato oil/vinegar salad, tasty as hell and the video was good too.
@harold-miller
@harold-miller 2 жыл бұрын
Great video! I work in Facilities and always try further my knowledge by watching you all work. Really appreciate you taking through your troubleshooting. Also, love the Keep Your Daydream S2R shirt! I’ve been following KYD since the beginning. 😎
@HVACRVIDEOS
@HVACRVIDEOS 2 жыл бұрын
Awesome bud yeah I love KYD I feel like I watched their kids grow up!!
@KES-ym5km
@KES-ym5km 2 жыл бұрын
Man I watch your videos all time. Such good content and learn so much. Appreciate the content!!
@MrMazizo121
@MrMazizo121 2 жыл бұрын
Great video . Thank you for sharing your knowledge.
@Ronald-qp8rn
@Ronald-qp8rn Жыл бұрын
Best looking air filters I’ve ever seen, maybe a maintenance contract!?!?
@GUSftw
@GUSftw Жыл бұрын
taking your time calmly is solid advice for any trade. in the general maintenance world sometimes you have supervisors breathing down your neck. i always brush them off basically and work like i normally do. the simple checks you do every single time, like checking transformer voltage etc. can save a lot of time if that happens to be the problem.
@jjeielrod
@jjeielrod 2 жыл бұрын
My favorite is when you go to fix something on Friday at 5pm, but it quit cooling on Monday morning. Lol
@Darryl_Frost
@Darryl_Frost 2 жыл бұрын
Great video thanks, very interesting, as an ex-electronics tech (mil radio, systems and computers), the wiring on those AC units looks shoddy AF... But it gets the job done.
@virtualomen3022
@virtualomen3022 Жыл бұрын
Yep, they all come out of the factory like that 😅 fortunately when a system is installed you generally don't plan on it moving untill it's time to replace, making further cable management and shielding unnecessary
@krisraps
@krisraps 2 жыл бұрын
OMG! I Do Exacly The Same With My Solder, I Put All The Leftovers Together To make A New One And Pinch A Penny :D !
@Eddy63
@Eddy63 2 жыл бұрын
Another good one Chris ... Thx for posting ...
@emylrmm
@emylrmm 11 ай бұрын
Superb repair and well narrated.
@dashcamandy2242
@dashcamandy2242 2 жыл бұрын
14:10 - I wouldn't call that being "cheap," I would call that "being fiscally-responsible during a time of rampant and unchecked inflation."
@crazydan2327
@crazydan2327 Жыл бұрын
Thats not cheap that's SMART boy I wish there were a few more good techs around here I just started working and quit 2 companies it was every 2nd day I'm walking into a shit show do it right or do it at all I'm refreshing with this and all ur videos 💪💪💪👍☝️
@DanO181919
@DanO181919 2 жыл бұрын
My old boss used to tell me- how do you eat an elephant? What bite at a time.
@EnderMalcolm
@EnderMalcolm 2 жыл бұрын
I know this feeling. Been baking out here in PA. Really wish I had my previous unit plugged into a surge protector D:
@RollerCoasterLineProductions
@RollerCoasterLineProductions 2 жыл бұрын
Fav new channel.
@anonamouse5917
@anonamouse5917 2 жыл бұрын
A Carlyle compressor walks into a bar. The barkeep says, "We don't see many Carlyle compressors in here". The Carlyle compressor responds, "And at the rate we leak refrigerant, you won't see many more."
@keehn20
@keehn20 2 жыл бұрын
Dude I use that wand for everything. It’s the best! Thanks for telling me about it last year
@RodrigoRamirez-fc5hv
@RodrigoRamirez-fc5hv 2 жыл бұрын
I'm glad you mentioned that about the 20 % poe oil addition to retrofitting 407c. I have not done that before but, I was thinking about it. .
@kyledakilla8724
@kyledakilla8724 Жыл бұрын
Maintenance needs to change those filters! Great video man!
@Kangenpower7
@Kangenpower7 Жыл бұрын
Dirty oil and moisture in the system can both cause the compressor to have a high ohms to ground.
@TheMetGuy
@TheMetGuy 2 жыл бұрын
Awesome video
@richierich7721
@richierich7721 2 жыл бұрын
thank you very informative
@tallbrian100
@tallbrian100 2 жыл бұрын
Many years ago I had a restaurant in the mall. Cooling was a coil in the air handler off of the malls chilled water system. We were also on the 3 floor so with windows and the rising heat it was not that great. Being in Wisconsin we had to get the coil winterized, filed with anti freeze for the winter. So the second winter I got a new company to winterize the coil and in spring they came back and the coil was freeze damaged. The company said it was not there fault but made the tech fix it on his own time.
@CryptoAbe
@CryptoAbe 2 жыл бұрын
Now this is quality. Great video may become a fan yet.
@patrickbeals2416
@patrickbeals2416 2 жыл бұрын
Got a little rosebud in there for ya
@joecorbin5158
@joecorbin5158 2 жыл бұрын
Busy day bubby Every one bear in mind the refrigerant circuit condition as your testing motor insulation Always make sure there is pressure available before testing.
@BrizzitHQ
@BrizzitHQ 2 жыл бұрын
Funny that this got recommended to me just now. Spent all night in my room in the Middle East with my AC being broken, well over 100 in my room. At least this was entertaining
@rudya.9734
@rudya.9734 2 жыл бұрын
EXCELLENT VIDEOS
@MrLandslide84
@MrLandslide84 Жыл бұрын
The leaking compressor: Bet it was a soft plug. There was a batch of small condensing units at my work where the receiver soft plug would leak early.
@johncasale2195
@johncasale2195 2 жыл бұрын
Chris your #ONE GREAT DETAIL TY
@Georges3DPrinters
@Georges3DPrinters Жыл бұрын
I was wondering how many ACs where down before the call. 3? 4? still good 😆 don't call till 5 are down.
@jnewv
@jnewv 2 жыл бұрын
I completely agree with what you said about the leak sealant but nobody listens lol
@patriknilsson2175
@patriknilsson2175 2 жыл бұрын
You're not a cheapskate brazing short pieces of solder together. As a Refrigeration installer/tech I do it CONSTANTLY myself after a tip from a co-worker, from when I begun my career for more than 10 years ago.
@stephenbullock1443
@stephenbullock1443 2 жыл бұрын
Great job
@yakacm
@yakacm 2 жыл бұрын
The Latin name for lead is plumbum, that's why plumbers are called plumbers.
@brake_4_cake
@brake_4_cake Жыл бұрын
5:45 dude, that view
@flyinghigh5531
@flyinghigh5531 2 жыл бұрын
I had a call at McDonald’s just the other day, kitchen up to 80. Found the OA sensor reading all over the place so it was only economizing too. Compressor would bump on and off for half a second. Was able to bypass until I got the sensor. Kitchen ACs are greasy!
@elvest9
@elvest9 2 жыл бұрын
100Mohms is below the limit? To me that still does sound like a very high resistance.
@jesrovalenzuela1346
@jesrovalenzuela1346 2 жыл бұрын
I did a compressor like this one 2 weeks ago and the terminals blew out of the compressor causing to lose the refrigerant.
@oooooollllllll
@oooooollllllll 2 жыл бұрын
i live in an old building and for years it got so hot in our building i thougth our ac was just too old and thats how it is. Legit 110+ degrees in our upstairs rooms sometimes. the housing management comes by oneday to give me some paperwork and they immediately ask whats wrong with our AC. they practically forget about the paper work and ask us how long its been like this and say since i moved in. I was like "i thought thats just how it is" they call our emergency maintenance and they come out the very next day and say it was out of some shit called Freon and then fix it in 10 minutes and now its down to 70 degrees in the middle of the heat.
@eggman9713
@eggman9713 Жыл бұрын
Just getting to see this video a couple months later but one thing that is important with JADE economizers is that even with a single-stage unit, you need to still use a two-stage thermostat input to the JADE. This is because when the JADE is in full economizer, if there is a call for Y2, it will turn on the Y1-out to turn on the first (or perhaps only) stage compressor to supplement the economizer (also known as "integrated economizer" operation). If it only sees a Y1 while economizing, it will never turn the compressor on, and on a mild day, it can result in undercooling the space. Always connect a 2-stage thermostat to a JADE regardless if it is a single or two-stage unit. Optionally, you can also set a "Y3 delay" on the JADE. If that Y2 call persists for more than a set number of minutes, while the economizer is operating, it will then kick on the Y2-out for second stage compressor if there is one. When it's not economizing, the Y1 and Y2 calls go through the JADE just like you would expect. I've done this on a church that has a two-stage system serving the sanctuary, and it's set up so that if it's economizing (Y1 call), and it sees a Y2 call, it will kick on the first-stage compressor, wait 15 minutes (Y3 delay), and if the Y2 call is still there, bring on the second stage compressor. It's one of those little things in the JADE manual that isn't necessarily obvious but it can save you a lot of headache and save the owner energy by not "fixing" the economizer by cranking down the mixed air setpoint to make the economizer operate less.
@tedhicks5431
@tedhicks5431 Жыл бұрын
Sucking in that good ole humidity
@dbbd9890
@dbbd9890 Жыл бұрын
In my country if you ignore a system with a refrigerant leak you get a massive fine. Toping up a leaking system you lose your licence immediately.
@CanogaHVACRLLC
@CanogaHVACRLLC 8 ай бұрын
Great video. Please, I need to know the info for that brazing nozzle.
@The201Ray
@The201Ray 2 жыл бұрын
Look at those filters!!!
@R4pidCL1Cker
@R4pidCL1Cker Жыл бұрын
wow even 407 is facing out in western europe. when we changeout a r22 system we use 448a(i also always change the oil). its illigal to buy and use r22 in the netherlands. i really miss r22. its a really good refrigirant.
@MariosACandRefrigeration
@MariosACandRefrigeration 2 жыл бұрын
for mineral oil use r422b,the same way you did r407c.tested for years.
@RobloxCoreGamer
@RobloxCoreGamer 2 жыл бұрын
Idk why but I feel like I’ve already seen one part of this video, Must be Deja vu
@PhillipFrischman-vo8gm
@PhillipFrischman-vo8gm 3 күн бұрын
You tell him full tell him lol.....
@zackhamilton7421
@zackhamilton7421 2 жыл бұрын
Another great and informative video Chris! It's refreshing that you are promoting doing the trade properly and not teaching how to "just get by". I actually have to admit that I did just that. My condenser fan motor was occasionally locking up at night and I tested my cap first which tested bad. So I just replaced that to "get by", however, 2 weeks later and I started having the same problem again... wake up in the middle of the night and it's 85 degrees and humid in the house. So I ordered a new fan motor and it was what I should have done to begin with. Because the bad bearings in the old motor ruined the new cap that I tried to get by with... (it was not overamping) So your educational videos have taught me a valuable lesson, with inflation going berserk it's best to do it right the first time. Because I would not have wanted to be changing my compressor had it been going off on thermal lock out too many times (being a 15 year old Mayag package unit). Cutting corners almost cost me more than just doing the work properly. Thank you for your wisdom and the Fieldpiece SC480. It has been a great Christmas gift from 2 years ago! Keep up the great content!
@jamesbernard3255
@jamesbernard3255 2 жыл бұрын
Those need units need thorough cleaning from the coils to the filters and everything in between.
@MELISOKOMIAAETOS
@MELISOKOMIAAETOS Жыл бұрын
hey i am an hvac technician from greece, i think you made a mistake you start washing the condenser while you have the vacuum pump working. its better to have presure in the system and after you wash it
@daveyt4802
@daveyt4802 8 ай бұрын
That costs double time extra. Tell them that next time.
@Itskaintmeenu
@Itskaintmeenu 2 жыл бұрын
hey nice sharing
@ejonesss
@ejonesss Жыл бұрын
great!!! wait until it is 100+ degrees when everyone is sweating to fix it.
@joelmcelrath6081
@joelmcelrath6081 2 жыл бұрын
Gotta get the oil out.
@1carlportl
@1carlportl 2 жыл бұрын
fun visit
@thewicksj
@thewicksj 2 жыл бұрын
They had 5 AC’s turned off at the disconnect and I was like this looks like a job for Chris. It wasn’t you cuz it was near Disneyland
@jamierushing8811
@jamierushing8811 2 жыл бұрын
Hi bro from west Alabama peace and love
@jeffreywhitlatch1409
@jeffreywhitlatch1409 2 жыл бұрын
As always, you get an atta boy for doing a good YOB.
@luispatino3180
@luispatino3180 2 жыл бұрын
Change the capacitor... done. 😄
@michaelhaiden6718
@michaelhaiden6718 2 жыл бұрын
Damn I call that a bingo
@stylez1989
@stylez1989 2 жыл бұрын
"hurry all every AC is down" In my mind, stop overreacting while walking in with my lazer reader to only be the one ac down lol
@gbuss814
@gbuss814 2 жыл бұрын
I was taught that the customer's emergency is not our emergency. You serve the customer better if you are calm and able to think. I have walked in many quite factories with the maintenance guy screaming and panicking. As long as I stayed calm I got the factory making noise. Great video!
@GlenS123
@GlenS123 2 жыл бұрын
That leak on side of compressor is a weld for upper bearing bracket, sucks for customer when they leak.
@tbelding
@tbelding 2 жыл бұрын
OEM approved. There are a couple of things that this could involve. 1) they want to mislead you on _which_ Original Equipment Manufacturer. It could be the manufacturer of a filter dryer. 2) They won't actually use a company name because _then they're stepping on the rights of the company_. 'You used our name without our permission!'. You _can_ use a company's name without permission, but only if you have specific evidence. Papa John's compared itself to Pizza Hut because the founder of PJ was involved in Pizza Hut, and they couldn't claim he couldn't know enough to compare. That's why you see "Compared to a leading competitor", instead of "Compared to company B!" If you contact the company, they may even tell you over the phone (or in email) what the OEM might be - but they can't do it in public. (published)
@stevenbarber2703
@stevenbarber2703 Жыл бұрын
so true
@edisona.543
@edisona.543 2 жыл бұрын
video recommendation. tips for hot summer days and staying safe?
@AvgDan
@AvgDan 2 жыл бұрын
Those economizers sure help create service calls.
WELL THAT'S NOT GONNA WORK....
34:38
HVACR VIDEOS
Рет қаралды 97 М.
LATE NIGHT WALK IN FREEZER CALL
40:08
HVACR VIDEOS
Рет қаралды 54 М.
Пранк пошел не по плану…🥲
00:59
Саша Квашеная
Рет қаралды 6 МЛН
Can A Seed Grow In Your Nose? 🤔
00:33
Zack D. Films
Рет қаралды 26 МЛН
Schoolboy - Часть 2
00:12
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 2,5 МЛН
THERE IS TOO MUCH SMOKE IN THE KITCHEN
51:34
HVACR VIDEOS
Рет қаралды 61 М.
Locked Compressors
20:13
HVAC School
Рет қаралды 109 М.
CARRIER PACKAGE UNIT LOW VOLTAGE ISSUES
26:36
HVACR VIDEOS
Рет қаралды 114 М.
IT'S TIME TO REPLACE THIS ONE
30:19
HVACR VIDEOS
Рет қаралды 50 М.
INSANE MOISTURE CONTAMINATION
44:35
HVACR VIDEOS
Рет қаралды 140 М.
THERE IS A LOUD GRINDING NOISE COMING FROM THE ROOF
42:33
HVACR VIDEOS
Рет қаралды 48 М.
HURRY OUR BRAND NEW MANITOWOC ICE MACHINE IS NOT WORKING
22:35
HVACR VIDEOS
Рет қаралды 28 М.
THE OTHER COMPANY COULDN'T FIGURE IT OUT
38:43
HVACR VIDEOS
Рет қаралды 191 М.
I LIKE WORKING ON EXHAUST FANS
14:24
HVACR VIDEOS
Рет қаралды 24 М.
THE EXHAUST FAN IS TOO LOUD
27:11
HVACR VIDEOS
Рет қаралды 29 М.