Like, Share and Subscribe for upcoming Tutorials. Join our Facebook Private Group: groups/28376... Fb Public Group: groups/26560... Excel Sheet download link: 1drv.ms/u/s!AqYdHIIRTM1thjguK...
Пікірлер: 47
@fatimabatool7838 Жыл бұрын
Great explanation sir. I am a Geotechnical Lab Engineer. This video helps me a lot. Love from India 🇮🇳
@ricardoestrada9422 Жыл бұрын
straight forward, easy to follow, and understand. Thank you sir.
@fosterkamudoni50892 жыл бұрын
Beautiful! Thank you so much @Naqeeb for even sharing the template
@muhammadarsalanamer19863 жыл бұрын
Thank you Sir Very good style of Explanation
@faithmlewa53362 жыл бұрын
Thank you so much. This really helped!
@trongsarkayta Жыл бұрын
Thank you very much from Japan. Indian explanation is more easy and understandable. Very difficult to find hydrometer detail test and calculation part in KZbin.
@trongsarkayta Жыл бұрын
The hydrometer reading label is from 1000 to 1050 in my case. As per your sheet, it is only 2 digit readings. Should I also take 1040 as 40 in your case?
@trongsarkayta Жыл бұрын
Why are you are taking the specific gravity of water at 25 degree only when you have different temperatures in your solution at different readings?
@HazratAli-oh6bl3 жыл бұрын
Good job. Please share the theory slides also. Thank You.
@momohmassaquoi81972 жыл бұрын
thanks very much, I like the method of teaching here.
@GeotechwithNaqeeb2 жыл бұрын
thanks alot 😊
@bipinkarki9664 Жыл бұрын
can you explain double hydrometer method for dispersive clay
@user-wx5xv3eq3g10 ай бұрын
Hello sir from where you have taken the Ra reading
@fatimabatool7838 Жыл бұрын
Please make videos on SBC calculations and Foundation design
@laxmanbehera20093 жыл бұрын
please explain about zero correction = 7 and time correction = 4.85+.25 and viscosity of water 0.00000922
@alaachannel16203 жыл бұрын
good job friend
@MajeedPodcast3 жыл бұрын
what's the standard you follow? Bs or ASTM?
@GeotechwithNaqeeb3 жыл бұрын
ASTM Standard
@keirahnikole99133 жыл бұрын
Good explanation we need also the calibration of hydrometer and excel calculation. Please.....
@GeotechwithNaqeeb3 жыл бұрын
its given in the end of video
@engr.md.titumirhasan55953 жыл бұрын
excellent
@simasubhadrashini2600 Жыл бұрын
Thank you so much
@mohammadaasifkhaja18923 жыл бұрын
Great sir. Would you tell me which code did you follow. ASTM or something else?
@GeotechwithNaqeeb2 жыл бұрын
ASTM
@tajorigia14298 ай бұрын
Which book did u prefer?
@momohmassaquoi81972 жыл бұрын
Do you have such a video on all soils laboratory testing??
@GeotechwithNaqeeb2 жыл бұрын
just visit our channel and fb page
@loujainsoliman14222 жыл бұрын
from where can we get miniscous correction?
@korosh138013824 ай бұрын
HI The hydrometer is set for lower meniscus reading, but since the liquid mixture is cloudy, lower meniscus reading is difficult, so the hydrometer is read at the highest adhesion of water to the stem, if the H151 hydrometer is used to correct the meniscus with a solution of pure water and separating substance ( with the same concentration used in the hydrometry test 125 ml 4%) and pour it into a comparative cylinder and the density of the place the gauge inside, because the solution is clear, the upper and lower parts of the meniscus can be read( it is noted that the temperature in both cylinders is the same as the comparative and hydrometric). the difference between the two readings of the meniscus number for each The test is constant .
@mahmudjamil41610 ай бұрын
Please give me the reference book regarding this test. Thank you
@mwirigiraphaelm26 күн бұрын
so whom are you while explain using your local language sir?
@chadychahinda8233 жыл бұрын
Thank you from the bottom of my heart. How could we contact you?
@GeotechwithNaqeeb2 жыл бұрын
naqeebnawaz32@gmail.com or at fb page "geotechwithnaqeeb"
@rgrrsgggf3 ай бұрын
Excel sheet?
@TheMraaqib2 жыл бұрын
Stroke's Laa.
@GeotechwithNaqeeb2 жыл бұрын
yes
@hidayatullah51613 жыл бұрын
Sir shear astm standard file for hydrometer analyses D 7928