Vent Study. Why, how to do it and how to interpret the results

  Рет қаралды 35,604

InIPED

InIPED

Күн бұрын

Пікірлер: 19
@ganapathybalasubramaniam8486
@ganapathybalasubramaniam8486 2 жыл бұрын
Thanks Kevin Dwyer for this wonderful presentation, so clear and simple.
@owowaoladipupo3260
@owowaoladipupo3260 2 жыл бұрын
Thanks Kevin.. Dry seal system simplified. Best presentation have ever seen on this subject.
@johnsmall9729
@johnsmall9729 Жыл бұрын
Thank you Kevin. Very useful analysis of problems, and solutions too!
@ravir9970
@ravir9970 2 жыл бұрын
Thanks Kevin Dwyer and John crane team for the crisp & clear presentation. Valuable content for DGS users.
@prakashmayyak9916
@prakashmayyak9916 2 жыл бұрын
Very good explanation. Thank you very much...
@AnthonyZgheib-l8j
@AnthonyZgheib-l8j 11 ай бұрын
Thank you so much for this video!
@syedsalikali2428
@syedsalikali2428 14 күн бұрын
Anyone can answer why a flow restriction or an orifice is usually placed in the primary seal vent line when considering the tandem seal design without intermediate labyrinth? Does the orifice directs the flow towards the secondary seal, given the back pressure it develops, and also 'cause secondary seal line has no nitrogen or other gas input like that in the intermediate labyrinth design? Here I saw the PSV in the primary seal vent line, but then it's a tandem seal with intermediate labyrinth.
@basabroy4918
@basabroy4918 2 жыл бұрын
Excellent presentation
@666windstar
@666windstar 2 жыл бұрын
Thanks for clear important, i have a question utilizing your John crane experience, When using dry gas seal in Centrifugal compressor is mandatory? other than hazardous gas service?
@gee1617
@gee1617 3 жыл бұрын
tell me what happened when refrence gas and buffer gas difference pressure is high is it damage the seal
@gee1617
@gee1617 3 жыл бұрын
tell me what happened when reference gas and buffer gas diffencal pressure is high is it damage seal?
@rareoaq
@rareoaq 3 жыл бұрын
Unless you exceed the pressure rating of the seal (which is unlikely if you are coming from discharge), a high differential pressure across the process laby shouldn't damage the dry gas seal. It would simply increase the flow through the process laby, up to a choked flow condition.
@MrRaminhodinho
@MrRaminhodinho 3 жыл бұрын
What pressure difference is there between the fluid entering the primary seal and the fluid heading towards the labyrinth seal
@rareoaq
@rareoaq 3 жыл бұрын
There is no pressure difference in the primary seal cavity, between the process laby and the primary seal. The pressure will drop as the gas moves across the primary seal face and the process laby (or any restriction in a flowing application). The pressure entering the primary seal is a controlled parameter, controlled by the support system to a setpoint in order to maintain a specified velocity across the process laby. The pressure downstream of the process laby is approximately equal to the compressor suction pressure (if the compressor is balanced). The pressure downstream of the primary seal is approximately equal to the primary vent back pressure, which is controlled with a back pressure regulator or a check valve with a specified cracking spring pressure (usually around 5 to 10 psig in normal seal conditions).
@MrRaminhodinho
@MrRaminhodinho 3 жыл бұрын
@@rareoaq thank you that was neatly explained
@MrRaminhodinho
@MrRaminhodinho 3 жыл бұрын
my question again is how is the pressure difference is distributed across the seal
@MrAlwinj
@MrAlwinj 3 жыл бұрын
useful info
@ashwinnarayan4450
@ashwinnarayan4450 Жыл бұрын
Can any body please send me what do it there is a loss of separation gas during centrifugal compressors operation with dry gas seal system in place
Types of Seals in Centrifugal Compressor
23:32
Mr Engineer
Рет қаралды 12 М.
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
How to treat Acne💉
00:31
ISSEI / いっせい
Рет қаралды 108 МЛН
Dry Gas Seals Basics
1:01:31
Ahmed Zaki
Рет қаралды 3,7 М.
Mechanical Seal Failure & Troubleshooting
10:33
Paul Brimhall
Рет қаралды 226 М.
When Digital Twin meets BIM
24:18
InIPED
Рет қаралды 3,9 М.
The Dome Paradox: A Loophole in Newton's Laws
22:59
Up and Atom
Рет қаралды 796 М.
How Compressor Gas Seal System Works?
12:00
Technical Engineering School
Рет қаралды 194 М.
Thrust Bearings Replacement-tolerances and Installation
5:50
Technical Engineering School
Рет қаралды 136 М.
Reciprocating Compressor C series - animation | Howden
3:12
Dry Gas Seal Hydrodynamic Grooves and How they Operate
2:42
Seal Animation
3:46
drewdevitt
Рет қаралды 74 М.