Installing a Lightning Conductor

  Рет қаралды 16,807

EcoHouseThailand

EcoHouseThailand

Күн бұрын

Пікірлер: 16
@gregcarroll9723
@gregcarroll9723 3 жыл бұрын
Great way to ensure protection of sensitive electronic equipment. Thermal welding is certainly different. Leads me to wonder if brazing is used in Thailand.
@MatPoyobro
@MatPoyobro 8 күн бұрын
Is it sufficient only one conductor installed on top of big roof.how if lightning strike at the other side.not the side with the conductor?
@AmericanInThailand
@AmericanInThailand 2 жыл бұрын
I had no idea about any of this. That was very interesting! Thanks!
@electrowashyelect9715
@electrowashyelect9715 6 ай бұрын
If a standing tower is behind the installation. Cant that the lighting arrestor if the towel gives a cover for the solar installations.
@electrowashyelect9715
@electrowashyelect9715 6 ай бұрын
The arrestor cable is sheilded from the building how about the solar panel frame is it necessary to be earthed ?
@chargeheadsuk
@chargeheadsuk 10 ай бұрын
Where is Thailand is this?
@awaisahmed4322
@awaisahmed4322 4 ай бұрын
What is the size of a down conductor?
@firstname5556
@firstname5556 Жыл бұрын
Do you also have a separate electrode linked to the Earth bar in the distribution board?
@EcoHouseThailand
@EcoHouseThailand Жыл бұрын
I have a separate ground rod for home electrics, another for my solar system and another for my solar thermal immersion heater.
@firstname5556
@firstname5556 Жыл бұрын
@@EcoHouseThailand Did you also test the soil resistivity and external earth fault loop impedance?
@TheStev08
@TheStev08 2 жыл бұрын
did they bond the Lightning System to the Solar Grounding system? or it should be seperated?
@EcoHouseThailand
@EcoHouseThailand 2 жыл бұрын
The grounding for the lightning conductor is separate from the solar grounding and much more substantial
@TheStev08
@TheStev08 2 жыл бұрын
@@EcoHouseThailand Thanks. It is good to know that it should be seperated. Is the AC and DC ground of the system is seperated also?
@EcoHouseThailand
@EcoHouseThailand 2 жыл бұрын
@@TheStev08 Yes
@keegang7402
@keegang7402 Жыл бұрын
According to the NFPA780 the grounding systems should be bonded
@SgtJoeSmith
@SgtJoeSmith Жыл бұрын
@@keegang7402 yeah i thought you bond anything metal, railing, pipes, solar panels, ac units on roof, lights, antenas, etc
On-Site ESE Lightning Arrester Installation - STEP BY STEP PROCEDURE!
5:35
Support each other🤝
00:31
ISSEI / いっせい
Рет қаралды 81 МЛН
Why aren't lightning rods more widely used?
3:00
KHOU 11
Рет қаралды 30 М.
Installing Whole House Lightning Protection | Ask This Old House
4:04
This Old House
Рет қаралды 190 М.
Grounding and Bonding an Electrical Panel
13:24
Appalachian DIY
Рет қаралды 348 М.
DIY Home Solar System Lightning Protection EMP Shield
18:26
Projects With Everyday Dave
Рет қаралды 45 М.
Lightning Protection Systems Video by Nott Ltd
11:52
TheLightningSage
Рет қаралды 55 М.
How to Install Whole-House Lightning Protection | Ask This Old House
8:26
Lightning Arrester Installation Step by step
8:33
Friends Tech Service
Рет қаралды 87 М.