Installing Temporary Power | Eaton RV Power Panel And Eaton Service Meter Installation

  Рет қаралды 21,062

BinaryView

BinaryView

Күн бұрын

Пікірлер: 16
@MikeEarned
@MikeEarned Жыл бұрын
I'm from Tracy and when I seen the school I was wondering if that was TCE. Then I heard you say you're from Monteagle. Thanks for sharing, I'm fixin to install one in Altamont this week. God Bless!
@binaryview6115
@binaryview6115 Жыл бұрын
Yes, that’s TCE and yes I’m currently in Monteagle, but I’m getting ready for the minimalist lifestyle in Tracy.
@goldentimez7397
@goldentimez7397 5 ай бұрын
Thanks gives me an idea of what im in for only difference on mine is a 50 amp 125/250 so im wondering if I hook up the same way or not 😮
@goldentimez7397
@goldentimez7397 5 ай бұрын
Because 110 and 110 is a 220 plug i need a 250 plug but im not to sure if that matters or not
@binaryview6115
@binaryview6115 5 ай бұрын
Yes it would, but you don’t have to order yours with the 30 amp. In my opinion it wouldn’t hurt to have both, because cost wise it’s going to be about the same price. Call your local power company and ask what are their requirements for a temporary power pole. My company gave me a diagram in pdf form. Thanks for your comment and good luck.
@binaryview6115
@binaryview6115 5 ай бұрын
I know it’s confusing but it’s supposed to be 120 from one leg to the center tap on your transformer. The transformer has two legs(hot) and a tap in the center(neutral) . From any of those legs to the center tap will be or supposed to be 120. From leg to leg you’re going to measure ruffly 240 volts. I’m guessing you haven’t studied electricity and I’m worried that my advice isn’t going help you do your own power pole safely. So, my advice is to either study electricity and get certified or get a certified electrician to guide you through the process or install it for you. Safety first! Thanks for your comment.
@rammannawar1626
@rammannawar1626 4 ай бұрын
Use a 125 panel with a 50 amp breaker to plug.
@FromTheHood2TheWoods
@FromTheHood2TheWoods 5 ай бұрын
Cute pet rat. lol adorable
@729Farms
@729Farms Жыл бұрын
What about neutral ground bond? Is it needed ?
@binaryview6115
@binaryview6115 Жыл бұрын
Yes, it will be bonded in this panel.
@samgibbs577
@samgibbs577 Жыл бұрын
What size wire did you use?
@binaryview6115
@binaryview6115 Жыл бұрын
4 awg
@729Farms
@729Farms Жыл бұрын
Is the power coming in from power company or from another panel?
@binaryview6115
@binaryview6115 Жыл бұрын
Power company.
@729Farms
@729Farms Жыл бұрын
What about ground rod?
@binaryview6115
@binaryview6115 Жыл бұрын
I’m only required to have a ground rod 8 feet deep because, I’m in a moist climate. In most cases I think you’ll be required to have two grounding rods at a minimum of 6 feet apart and 8 feet deep.
Installing a Temporary Electric Service Pole
10:20
The Homestead Craftsman
Рет қаралды 322 М.
200 amp outside service box
31:12
Robinson Homestead
Рет қаралды 31 М.
Wait for it 😂
00:19
ILYA BORZOV
Рет қаралды 11 МЛН
CAN YOU DO THIS ?
00:23
STORROR
Рет қаралды 49 МЛН
Это было очень близко...
00:10
Аришнев
Рет қаралды 7 МЛН
Family Love #funny #sigma
00:16
CRAZY GREAPA
Рет қаралды 41 МЛН
Install RV pole Parts needed, Installation, Prices, RV receptacle
5:47
Electrical Code Coach
Рет қаралды 8 М.
Temporary underground electric service
6:26
michael stevens
Рет қаралды 1,6 М.
RV 30A and 50A Shorepower Explained.
12:25
RVProject
Рет қаралды 79 М.
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,5 МЛН
Temporary Power During New Construction
3:54
Electric Pro Academy
Рет қаралды 18 М.
200amp power pedestal RV 30amp, and 110v gfci plugs~How I Did It~
7:08
DIY Temporary Electrical Service Installation
14:36
Daniel Woodell
Рет қаралды 86 М.
Temporary Power Pole Installation | Forest to Farm
15:59
Survival Dispatch
Рет қаралды 13 М.
10 Common Mistakes DIYers Make In Circuit Breaker Boxes
13:55
LRN2DIY
Рет қаралды 2,6 МЛН
Wait for it 😂
00:19
ILYA BORZOV
Рет қаралды 11 МЛН