Insulation Resistance Tester - Real World Examples

  Рет қаралды 26,643

AnotherMaker

AnotherMaker

Күн бұрын

Пікірлер: 48
@fobmongrel9925
@fobmongrel9925 2 жыл бұрын
Thanks for those examples! Seeing these with my own eyes was very educational!
@AnotherMaker
@AnotherMaker 2 жыл бұрын
Ahh. Thanks for watching. Glad it was helpful. TBH, I learned a lot making it.
@procrastinator1842
@procrastinator1842 2 жыл бұрын
If you get the UT526 it has continuity built in, and also tests rcds. It's a bit more money but a much more complete and useful meter.
@AnotherMaker
@AnotherMaker 2 жыл бұрын
Awesome. Good to know. Thank you.
@danielelise7348
@danielelise7348 Жыл бұрын
It's not "zero" L, it's "O"L for "Open Loop" in continuity & "Over Limit" when in range.
@hunnybunnysheavymetalmusic6542
@hunnybunnysheavymetalmusic6542 2 ай бұрын
I ONLY JUST learned about this... And it just may be what I need because I have a 3 phase motor that may have an insulation leak.
@ashvanbro9329
@ashvanbro9329 2 жыл бұрын
Yes you can use it with out the other
@echeverriaemilio
@echeverriaemilio 24 күн бұрын
Thank you!!
@oddsman01
@oddsman01 Жыл бұрын
An ignition circuit on your car produces between 30-40KV. It’s annoying when you’re zapped by one, but not that bad. A zap from static electricity is usually around 5KV. It’s not the voltage that does the damage. It’s current.
@AnotherMaker
@AnotherMaker Жыл бұрын
Absolutely.
@ЭлектроСафоново
@ЭлектроСафоново Жыл бұрын
8:36 Таким методом,с помощью ванны с водой можно измерять сопротивление изоляции рабочего инструмента- кусачек,пассатижей и отвёрток. Хороший способ.
@AnotherMaker
@AnotherMaker Жыл бұрын
That sounds like a fun experiment.
@ЭлектроСафоново
@ЭлектроСафоново Жыл бұрын
@@AnotherMaker This will be the right experiment. One electrode (positive) is connected to the metal part of the tool and the second electrode (negative) is connected to a container of water. Immerse the insulated handles of the tool into the water and measure the resistance. If there is damage (cracks) in the insulation, then the megohmmeter will show low resistance. This is a fairly accurate way. Naturally, be careful when working with high voltage. Good Luck,sincerely.
@pedrojardim325
@pedrojardim325 5 ай бұрын
Good stuff men
@UKsystems
@UKsystems Ай бұрын
Are these not common for electricians to use in the US when she went installation certificate? Certify? It’s good or not? Because the way these comments are peoples seem to think it’s revolutionary to check an electrical installation is safe
@gregorynatanson6923
@gregorynatanson6923 7 ай бұрын
Would it be ok to use it on fire alarm circuits to find a ground fault? Power 12-24 vdc and data 6-20 vdc. Thank you.
@ToBeDefined85
@ToBeDefined85 2 жыл бұрын
I don't understand the difference in the "Multiple points of failure" test. Both multimeter and insulation tester detect continuity. What is the difference?
@AnotherMaker
@AnotherMaker 2 жыл бұрын
it is possible that a "normal" continuity test will tell you if something is shorted because it doesn't have enough current or a high enough voltage to detect the short.
@1I2am3Dani4
@1I2am3Dani4 Жыл бұрын
Your multimeter tests continuity with a few volts and pretty much no current which won't reveal any issues you might experience under actual live conditions (where your voltage might be anything from 110V up to 400V depending on your country and grid).
@matiasdimaurizio
@matiasdimaurizio 4 ай бұрын
Es normal ese ruido a chispa que larga el megohmetro?
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
You test the meter is working correctly by pressing the test button test leads apart you should get a zero reading short the lead together press test you should get full scale deflection. This tells you the meter is working correctly .
@AnotherMaker
@AnotherMaker Жыл бұрын
Good tip. Thank you!
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
@@AnotherMaker those UNI-T test are fantastic for learners and apprentices. Just starting out . Once they have experience they can upgrade to one of the big brands like fluke
@repa77777
@repa77777 4 ай бұрын
you mean the opoosite??
@rpmi-1640
@rpmi-1640 8 ай бұрын
How would you replicate the water tray experiment in the real world, say an outdoors cable has snagged and ends up surround by moisture collected in the conduit. Would you stick the ground probe on a nearby ground terminal of straight into the soil? Would you then expect to get way less than 5.5 GOhm?
@inothome
@inothome 4 ай бұрын
Connect it to the conduit, if metal and then one of the cable leads. Or the ground lead in the cable run, or between the neutral and line with the devices disconnected. Anything less than 2M Ohm may cause problems. Anything much lower than that will cause problems.
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
The uni-t 501 reads megger ohms on the 250v and 500v range , not gig ohms, the minimum acceptable value for insulation resistance is >1 magohm ie greater than 1 Megohm the maximum that tester can display is ol = over limit or l = over limit ie full scale deflection. On new installations we expect to see full scale deflection .
@AnotherMaker
@AnotherMaker Жыл бұрын
You seem to know a lot about this. I really appreciate the tips.
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
@@AnotherMaker yes I have been an electrician for a little over thirty years . I am in UK 🇬🇧
@theshuff
@theshuff Жыл бұрын
dont know how you are supposed to test isolation in your country, but in france, isolation tests are never done between live and neutral wires. Tests are only done between neutral and earth, live and earth and finally between live wires in industrial electrical setup.
@AnotherMaker
@AnotherMaker Жыл бұрын
What's the downside of testing between live and neutral?
@theshuff
@theshuff Жыл бұрын
​@@AnotherMaker in "real world" you have terminal components plugged between live and neutral (computer, light bulb...). it's not advisable to inject 500+vdc even with low current. Only revelent test that should be done between live and neutral is a short circuit test with ohm multimeter.
@virgiliomaceda5337
@virgiliomaceda5337 5 ай бұрын
do you have a copy of calibration certicate, can i get a copy?
@bl00dyglass
@bl00dyglass 2 жыл бұрын
Is the Insulation Resistance tester emitting DC or AC voltage?
@AnotherMaker
@AnotherMaker 2 жыл бұрын
I believe it can do both
@brentfixesstuff
@brentfixesstuff Жыл бұрын
The 500v test is performed I DC.
@carlosgarcialalicata
@carlosgarcialalicata 2 жыл бұрын
Does that little device really can produce 1000V? isn't that dangerous? What would it do if you connect a varistor in there? :)
@AnotherMaker
@AnotherMaker 2 жыл бұрын
I think it really does 1000v. The varistor sounds like an interesting experiment.
@stevenspmd
@stevenspmd 2 жыл бұрын
Even the much cheaper BM500A will do 1000V; "TheHWCave" has a review/safety discussion of that one.
@procrastinator1842
@procrastinator1842 2 жыл бұрын
It's 1000v at about 1mA of current. So very little energy, but enought to give you a surprise shock.
@brentfixesstuff
@brentfixesstuff Жыл бұрын
It's 1000v DC not AC so it makes a difference.
@MaN2Mega
@MaN2Mega Жыл бұрын
Is this megger appropriate for the automotive 12V system ?
@AnotherMaker
@AnotherMaker Жыл бұрын
Yes, I don't see why not.
@MaN2Mega
@MaN2Mega Жыл бұрын
@@AnotherMaker Well I'm not fully sure how they function, my fear is that a megger made for more robust wires, 230V AC here in Europe maybe would damage wires in the 12V system?
@petermichaelgreen
@petermichaelgreen 5 ай бұрын
Its' fine for testing wiring but be careful nothing is connected first.
@georgilafchiyski2052
@georgilafchiyski2052 2 ай бұрын
I testing diesel (piezo, etc ) injectors in automotive diagnostics because specially with misfire and if u use multimeter resistance is ok but when I use this 501 insulation tester LOL shorted not fully injector .​@@MaN2Mega
@alexstone691
@alexstone691 2 жыл бұрын
5:04 It says >5.50G ohms
@AnotherMaker
@AnotherMaker 2 жыл бұрын
Good call :)
Câteva impresii despre testerul pentru rezistenta de izolație Uni-T UT502A
15:26
Minecraft Creeper Family is back! #minecraft #funny #memes
00:26
Inside Out 2: ENVY & DISGUST STOLE JOY's DRINKS!!
00:32
AnythingAlexia
Рет қаралды 14 МЛН
pumpkins #shorts
00:39
Mr DegrEE
Рет қаралды 64 МЛН
Introduction to insulation testing using a Megger
19:05
The Electricians Guild
Рет қаралды 52 М.
This is the BEST Diagnostic Tool (and how to use it)
1:00:20
Mechanic Mindset
Рет қаралды 30 М.
Insulation Resistance Part 1 - Why do it?
13:24
JPElectric
Рет қаралды 29 М.
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 2,2 МЛН
Minecraft Creeper Family is back! #minecraft #funny #memes
00:26