No video

Inverter setup

  Рет қаралды 15,783

Zein

Zein

Күн бұрын

How to set up your smart inverter the right way .
5.2 Kw. 48 volt battery system.

Пікірлер: 26
@nthabisengselolo2425
@nthabisengselolo2425 4 ай бұрын
I recently bought 3kw Must Inveter and 2.56 Lithium inveter. And i am off grid ( no electricity at all ). My battery does not last the whole night even if i have only lights on and no other appliances. What could be the problem?
@RoyWagembi
@RoyWagembi 13 күн бұрын
I have a problem the Solar panel is not chargeing the battery it is not shown on the display screen why ? It should indicater show arrow pointing from panel to battery please assist me.
@MkatekoChestar
@MkatekoChestar 2 ай бұрын
Hello Sir please help out i have a brand new hybrid buy when i plug a fridge the inverter fan start yo run non stop and when i plug my t.v the pictures are not clear with vertical lines as well what could be the problem?
@josephbmpundu3482
@josephbmpundu3482 Ай бұрын
Please advise what is the best settings for Error Code03 ?
@EdmundDanielSagapuna
@EdmundDanielSagapuna 5 ай бұрын
I install Must Solar Inverter EP 1800 Model (5KW) and when I energized it everything was ok and than after three day the inverter goes off and 03 Error, and 02 Error display on the screen. What problem and how can rectified the proplem.
@zeinmohamed699
@zeinmohamed699 5 ай бұрын
Code 02 is the inverter temperature is too high over 90 C . You have many equipments running on your inverter. Check if the fun is running ! Code 03 is battery over charging. You have to reset battery charging level to lower one .
@oc7406
@oc7406 5 ай бұрын
Thanks for the video, I have a problem with mine, because the PV icone doesn't show in board. How can you help me?
@zeinmohamed699
@zeinmohamed699 5 ай бұрын
I think something to do with circuit board or the display. Try to reprogram it again and see what happens. If it doesn’t work , it could be the reason you miss wire it , check the positive wire coming from the pv connected to positive pole at the inverter and negative wire from pv connected to the negative side of the inverter. Good luck
@oc7406
@oc7406 5 ай бұрын
Thanks for answering, but how can i reprogram it?
@zeinmohamed699
@zeinmohamed699 5 ай бұрын
@@oc7406 follow my set up in my video from 1 to the end of
@oc7406
@oc7406 5 ай бұрын
@@zeinmohamed699 i did it, but it doesn't work
@zeinmohamed699
@zeinmohamed699 5 ай бұрын
@@oc7406 something wrong with the software of your inverter . As long as it’s charging , don’t worry about it .
@givenchapula
@givenchapula Ай бұрын
My 3.2kv must inverter is not charging when power comes what is wrong? It is only start charging with solar panels
@shruthithomas9489
@shruthithomas9489 7 ай бұрын
I have the ELLIES 3kW/5.2kW Solar Inverter. I am not sure which program option to set. Please assist.
@zeinmohamed699
@zeinmohamed699 7 ай бұрын
Hi If you have 3 kw. System more likely your batteries are 24 volts , In this situation my program doesn’t apply to your system. If your system is 5.2kw. That means it works on 48 volt system , so you need 4 batteries of 12 volts each . In series to make 48 volt system. Again your inverter has to be MUST inverter. Because it varies little bit from one type to another.
@YukkoSergii
@YukkoSergii 9 ай бұрын
not five B U, but S B U Solar, Battery, Utility.
@amelsekic875
@amelsekic875 2 ай бұрын
I need help
@kelvintogaraseyi
@kelvintogaraseyi 7 ай бұрын
Pv18-5048 : failing to select pv input for solar charge controller
@zeinmohamed699
@zeinmohamed699 7 ай бұрын
Hi It could be something wrong with pv connections, Check all your MC 4 connectors . Also check the positive and negative wire coming from your pv. Into your inverter.
@abyyatn
@abyyatn 4 ай бұрын
عند الافلتر ماعم يأقلع غير لم عم حملو
@donlekhuleni5498
@donlekhuleni5498 7 ай бұрын
I'm getting error code 03 , high voltage
@zeinmohamed699
@zeinmohamed699 7 ай бұрын
It depends on how many batteries you have , go back to setting # 11 and put it at 30 amp. If you have 4 batteries . If you follow all my settings you shouldn’t have any problem. I have no issues with my settings . It’s been running for two years without any problems.
@donlekhuleni5498
@donlekhuleni5498 7 ай бұрын
I'm using Svolt 48V/5.09 kWh LiFePO4 Battery. Does this mean I have four batteries in the pack?
@zeinmohamed699
@zeinmohamed699 7 ай бұрын
@@donlekhuleni5498 It looks you have one 48 volt battery, and about 5 kw. My system is 48 volt system with 12 led acid batteries. 200 Amp. Each Total power is 30 kw. Anyway, try to reduce the setting voltage from by one or two voltage and see what happened . Good luck .
@donlekhuleni5498
@donlekhuleni5498 7 ай бұрын
Thank you , I'm not winning so I have switched off the system completely and called my technician
@Riyadh7y
@Riyadh7y Ай бұрын
bro wtf
💡Підключення та налаштування інвертора |Must 3024 VPM|
8:14
Світло в темряві 💡
Рет қаралды 71 М.
Solar Energy Project With the New MUST 3000W Off Grid HYBRID INVERTER.
17:11
Erivaldo Grid Solar
Рет қаралды 67 М.
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 12 МЛН
SPONGEBOB POWER-UPS IN BRAWL STARS!!!
08:35
Brawl Stars
Рет қаралды 22 МЛН
How Many 12V Batteries for 3000W Inverter
15:26
Cleversolarpower by Nick
Рет қаралды 56 М.
Dica Inversor Must PV18 3024 VPM
13:35
Panda Energia Solar
Рет қаралды 7 М.
SunGoldPower 24V Parameter Setup
14:18
HomeInsteadSeligman
Рет қаралды 2,2 М.
Gospower Lithium battery works with MUST inverter
1:31
Gospower Energy
Рет қаралды 2,8 М.
Taiyo inverter ဆက်တင်ချိန်ခြင်း
2:22
How to Size Solar Charge Controller #solarpanelinstallation #solarenergy