Irritrol leaking valve (low-pressure irrigation valve system)

  Рет қаралды 7,684

FancyPlants

FancyPlants

Күн бұрын

This Irritrol 2711 ARP, which is an antisiphon type valve, just decided to start randomly leaking all of a sudden but ONLY when it shuts off, not while running. I found only a video or two of people having the same problem, though it seems to be VERY COMMON, and only one showed a solution. So I also tried to get a new cap/diaphragm to fix the leak. Did it work? Well, take a look.
I'm looking for comments here to help me out. Let me know what you think I should do!
Please like and subscribe to my channel so I can grow and continue to bring you informational videos about tons of rare plants. Many more coming soon!
FOLLOW ME:
Instagram: / fancyplantsla
Etsy: www.etsy.com/s...
TikTok: @fancyplantsla
What's growing in your collection? Growing for fruit, foliage, flowers, fragrance, or all of them?
Grow something interesting. Let me know what it is :)
#boyswithplants
#boyswithplants
#containergardening
#endangered
#eugenia
#food
#foodforest
#fruit
#fruits
#fruittrees
#garcinia
#growyourownfood
#guyswithplants
#Hawaii
#plantdaddy
#plantparent
#plantparent
#plantsmakepeoplehappy
#plantsplantsplants
#plantsplantsplants
#plinia
#rare
#rarefruit
#rareplants
#socal
#southerncalifornia
#superrare
#threatened
#tropicalfruit
#ultrarare
#urbanjunglebloggers
#urbanjunglebloggers
#irrigation
#valve
#irritrol

Пікірлер: 8
@eprieto3
@eprieto3 10 ай бұрын
Actually, the problem is not with the valve itself but its height. Your valve is doing precisely what it's supposed to. An anti-siphon valve should always be installed higher than the highest point in the system it controls. I'm guessing you have sprinklers somewhere that are higher than the head of this valve. Find the highest point in this system, then add pvc extenders to raise the height of your valve above that point and your problem should be solved. (I had this problem myself.)
@jeffbroders9781
@jeffbroders9781 Ай бұрын
Brand new Genie valves I installed. I do have check valves, but they still leak.
@bigdaddybk8817
@bigdaddybk8817 11 ай бұрын
Hmm... After your fix, the leaking indeed stopped. You had some minor backflow after the system.stopped running, but after it quickly stabilized, your video seems to show that the leaking stopped. No further drips occurred after the backflow trickled down and ceased. Right? Am I missing something?
@FancyPlants
@FancyPlants 10 ай бұрын
This was on a zone in which we added a higher set of sprinkler risers, so it was definitely a back-flow issue for part of it. You are correct, if it was just a back-flow issue only, it would stop. But then if you kept listening, there was a little trickling sound that kept happening and Flume kept giving us a leak alert. Ultimately, we had to have it replaced along with some other work and it's better now. The backflow issue is only about 1/4 the water you see in this video, so not nearly as bad and no more trickling sound.
@robertparkhill8106
@robertparkhill8106 3 ай бұрын
Did you ever try putting check valves on your actual line somewhere between the valve and the sprinklers? I believe check valves stop water from going backwards in the line.
@marierasmussen7799
@marierasmussen7799 3 ай бұрын
I have the same problem. Water is leaking through the valve into the vacuum chamber. It has been leaking for over 48 hours and it is 6" above all sprinklers.
@sidtp7307
@sidtp7307 Жыл бұрын
Did you find a fix? Having the exact same issue with a 2400T Purchased a new valve and replaced all the top parts but still a steady leak
@FancyPlants
@FancyPlants Жыл бұрын
Both yes and no. One of the valves was definitely broken but then another one started to do it and we spent all this time and money getting someone to come out and finally replacing it and doing a bunch of changes but it still does it. And you know what… it was my own silly fault. I installed a raised misting system on two of the valves. just so some of the plants can get some air moisture in our extreme heat and it’s the backflow that’s coming out of the valves which is natural. So in if any of the irrigation emitters are above the level of the valve, It will do this. So let’s say your valve is 1 foot above the ground but elsewhere in your yard you have some emitters that will be 3 feet above, this is just natural and the way it is supposed to work - just a waste of water but it’s to prevent water from going back into your main pipe.
Irritrol 2700 Series Anti-Siphon Valve
5:39
Sprinkler Nerd Andy
Рет қаралды 11 М.
How to Fix an Rain-Bird Anti-Siphon valve no glue - no pipe cutting
12:49
Perfect Pitch Challenge? Easy! 🎤😎| Free Fire Official
00:13
Garena Free Fire Global
Рет қаралды 91 МЛН
Миллионер | 3 - серия
36:09
Million Show
Рет қаралды 1,5 МЛН
Who's spending her birthday with Harley Quinn on halloween?#Harley Quinn #joker
01:00
Harley Quinn with the Joker
Рет қаралды 26 МЛН
Fixing a leaking sprinkler (anti siphon valve)
8:10
AmyAroundTheHouse
Рет қаралды 70 М.
Troubleshooting irrigation sprinkler valves
12:22
spelunkerd
Рет қаралды 837 М.
Sprinkler Valve Failure
3:27
Gary's Sprinkler Repair
Рет қаралды 19 М.
How to repair Orbit anti-siphon valve
3:15
Orbit Lawn Garden Life
Рет қаралды 83 М.
How to Diagnose an Anti-siphon Sprinkler Valve Leak Easy| You Must Know
2:38
ES Complete Yard Work
Рет қаралды 12 М.
Irritrol 2500 Irrigation Valve Diaphragm Replacement Tricks
5:30
Irritrol 205 Valve How To Rebuild (Sprinkler Valve)
14:02
Pro Irrigation Training
Рет қаралды 21 М.
Sprinkler valve replacement mistakes to avoid and tips.
7:23
westvalley411
Рет қаралды 91 М.
Fixing A Sprinkler Valve "Quick Fix," No Glue
13:41
Gary's Sprinkler Repair
Рет қаралды 460 М.
WHY YOUR SPRINKLERS ARE CONSTANTLY LEAKING.
4:12
ValleyScape Irrigation & Outdoor Lighting
Рет қаралды 237 М.
Perfect Pitch Challenge? Easy! 🎤😎| Free Fire Official
00:13
Garena Free Fire Global
Рет қаралды 91 МЛН