Thank you! Awesome video very helpful and highly appreciated Thx again PLUMBER-TOM
@plumber-tom9470 Жыл бұрын
Glad it was helpful!
@tommyailie8366 Жыл бұрын
Doesn't the stool have to be the last fixture on a horizontal vent system?
@plumber-tom9470 Жыл бұрын
By stool do you mean toilet? When wet venting each fixture is required to have an individual connection to the vent. The drain is considered a drain and vent down to the last fixture. So as long as the toilet is connected to the wet vent it does not have to be the last fixture in a line.
@bahaamouri9198 Жыл бұрын
Dude could you please share the link of that app/software yoy use ? It’s IOS or android? I couldn’t find it at all help please
@plumber-tom9470 Жыл бұрын
I use the ReMarkable 2 tablet. It connects to my computer and then I record the screen so I can draw. Here is a link. remarkable.com/?gad_source=1&gclid=CjwKCAiAsIGrBhAAEiwAEzMlCxdpjLzzb6cuVXAy-Q75IxWZt4RNoSIox1XoWY-PS7CefuLpo-4lnhoCgBsQAvD_BwE
@KenMickelsen Жыл бұрын
To the lav in floor plan it looked like two 45's. Im taking my exam soon and wondering if thats how its done or are you representing a 90 when going horizontally into main? Thanks
@plumber-tom9470 Жыл бұрын
You can use a long sweep 90 or two 45s. Either option is fine. But two 45s provides better flow.
@javiersanchez_marquez7 ай бұрын
What does a k mean ? kitchen sink? On an isometric plumbing drawing, I need to understand the letter meaning, lav lavatory for example, WC, (toilet water closet) what else would be? that affects the fixture units, or drain. Thank you
@plumber-tom94707 ай бұрын
Sorry. Not sure what you mean. There are not any K's in this video.
@smashedcarbon9277 Жыл бұрын
What app/software are you using to draw this?
@plumber-tom9470 Жыл бұрын
I use the ReMarkable tablet to draw. It can connect with my computer through Wi-Fi and shows real time what I am drawing. Then I screen record with Camtasia.
@shawnbarg32865 ай бұрын
Toilet needs to be installed downstream of all the other fixtures on a wet vent
@plumber-tom94705 ай бұрын
Right. According to UPC
@burke6.0 Жыл бұрын
Guy you need to learn how to plumb that is not how you pull a vent brother has to be a branch not the run of a y and rolled above center line
@plumber-tom9470 Жыл бұрын
Pretty sure I know how to plumb. Some codes might not allow this but it is basic wet venting. You are correct though. This is not ok where dry venting or individual venting is required. International Plumbing Code allows for wet vent connections below the center line.