Excellent video, subbed to your channel. Thanks for all your technical information presented in an easy and engaging way.
@plumber-tom947026 күн бұрын
Awesome, thank you!
@alexanderwalsh40863 ай бұрын
Awesome video, Tom. Thank you so much!
@plumber-tom94703 ай бұрын
Thanks!
@matthewhalford2650 Жыл бұрын
Why is it a violation at 16:13 but not in the example at 15:33 where it’s a single bathtub entering upstream of the wet vent? Is it because there’s two separate fixtures or just solely that the WC needs to be downstream of the wet vent?
@plumber-tom9470 Жыл бұрын
Hey. Good question. If you look closely, the bathtub in 16:33 is upstream from the lavatory vent connection. This means that it does not have an individual connection to the vent because the vent begins and the lav and goes downstream from there. The problem is that both the toilet and the bathtub are upstream. If it is just the toilet or the shower, that is okay, because the fixture connects to the vent at the lavatory, but when two fixtures are upstream in this example, it is a violation because you cannot have multiple fixtures with one connection to the vent. Does that make sense?
@matthewhalford2650 Жыл бұрын
Thanks a bunch! Learning a ton from your videos!
@plumber-tom9470 Жыл бұрын
Thank you for watching! I appreciate the support! @@matthewhalford2650
@fredbriggs222511 ай бұрын
Where did you find the exception for toilets, regarding distance from trap to vented line? Is that how you read 909.2?
@plumber-tom947011 ай бұрын
Hello. Good question! I got that information from the International Plumbing Code Commentary book some years ago. It was drawn out and labeled on several diagrams. Now that you ask, I am having a hard time finding it in the code. It might have been their recommended interpretation. I or it might be in the IRC. I will keep looking.
@jeffrandi7 ай бұрын
Why does UPC require water closet to be most downstream connection to a horizontal wet vent (and shown such in the video examples) but IPC does not indicate this requirement?
@plumber-tom94707 ай бұрын
IPC and UPC handle wet venting differently. The UPC is generally more restrictive.
@hustlehardstudyharder81975 ай бұрын
"909.1 Distance Of Trap From Vent" is that applicable to wet vents or is that for dry venting only???