HVACR Training: How To Wire RANCO Electronic Temperature Control (RANCO ETC111000-000 Wiring)

  Рет қаралды 4,375

Jumper man Tech

Jumper man Tech

Күн бұрын

Пікірлер: 15
@zekenzy6486
@zekenzy6486 11 ай бұрын
Great Video. Thank you for sharing. I'm waiting for watch next video. Have a nice week.
@brandoncorrea511
@brandoncorrea511 11 ай бұрын
Alright can’t wait for the troubleshooting
@sherwinalvarez7365
@sherwinalvarez7365 11 ай бұрын
Or... Or adding a Grasslin 115V or DTAV40.
@stevencossaboon3237
@stevencossaboon3237 11 ай бұрын
Nice work Jumper man. Thank you
@billyhorton5779
@billyhorton5779 11 ай бұрын
Good stuff, thanks JMT!
@briancarlisi2224
@briancarlisi2224 11 ай бұрын
One question is on your last example wired for 120v you showed the orange jumper from 120 to the C terminal with the yellow from the NC terminal to the solenoid. I’m confused about the red coming from C (where the orange jumper terminates) but where does the red terminate? The diagram didn’t show a second wire coming from C. What am I not understanding? Thanks for taking the time to explain.
@barrybroderick5103
@barrybroderick5103 11 ай бұрын
Was wondering the same , I don’t think there should of been a second wire coming out of the c terminal in both examples 🤷🏻‍♂️ as per the diagram
@harrydickson4575
@harrydickson4575 11 ай бұрын
Awesome 👍👍👍
@kennethlobo4420
@kennethlobo4420 11 ай бұрын
Thank U jumper man Tech
@nicolerennie
@nicolerennie 10 ай бұрын
love these training vids!
@artdacunha11
@artdacunha11 9 ай бұрын
HVAC student here from Canada. How would you connect this to a defrost timer? ..or is it odd to wire it up with a defrost timer?
@youtderek
@youtderek 8 ай бұрын
This would be wired on the NC portion of the defrost timer. So when the defrost timer is not in a defrost cycle, it is supplying voltage to this thermostat. When the box temp rises above the thermostat setpoint it will open the solenoid and allow refrigerant from the receiver to feed the evaporator. Once the evaporator picks up enough heat, the liquid refrigerant is boiled to a gas and the low side pressure (back pressure rises). On a separate circuit is the low pressure switch, once the low side pressure exceeds the setpoint of the low pressure switch, it activates the compressor and the refrigeration cycle begins. Once the box temp reaches below the setpoint of the thermostat, the thermostat no longer energizes the solenoid and refrigerant is no longer fed to the evaporator. The low pressure switch continues to energize the compressor until it reaches its low pressure setpoint (usually around 5psi) and the refrigerant is pumped into the receiver (aka pumpdown).
@artdacunha11
@artdacunha11 8 ай бұрын
thanks for the reply, I appreciate it!
@Herewegoagain797
@Herewegoagain797 11 ай бұрын
Looks like according to his schematic, he ran the N back to the Common on the bottom contact instead of back to the Neutral side of the load. Could use some clarification on that cause it looks like he would just be shorting the contacts by sending N back to its hot side.
@ILoveKittys78
@ILoveKittys78 11 ай бұрын
😻💚💜💚
Wiring a Thermostat and Solenoid explained
8:10
CSC refrigeration and hvac
Рет қаралды 40 М.
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 623 М.
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 116 МЛН
Правильный подход к детям
00:18
Beatrise
Рет қаралды 10 МЛН
Каха и дочка
00:28
К-Media
Рет қаралды 3,3 МЛН
Thermostat Wiring Explained!
10:35
Benjamin Sahlstrom
Рет қаралды 1 МЛН
Nest Common Wire Hack!!! - Nest Low Power Fixed
12:40
One Hour Smart Home
Рет қаралды 706 М.
Ranco etc111000 tstat
8:22
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 13 М.
Basic walk in box control wiring
12:30
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 61 М.
Сестра обхитрила!
00:17
Victoria Portfolio
Рет қаралды 623 М.