How To Measure SUPERHEAT and SUBCOOLING (HVAC 101) Air Conditioning and Refrigeration Training

  Рет қаралды 52,948

Jumper man Tech

Jumper man Tech

Күн бұрын

Пікірлер: 47
@kennethdandurand3472
@kennethdandurand3472 3 жыл бұрын
6:33 is probably the most helpful to newbies as anything I have seen. Copy it!
@ThantbraveLinn
@ThantbraveLinn Жыл бұрын
very good clip.very useful one
@Davidjames70
@Davidjames70 Жыл бұрын
Great Video !! Really easy to understand. Thank you!
@izzybell11
@izzybell11 4 жыл бұрын
Interesting and well explained material. As always thanks for sharing your knowledge with us. 👍👍👍👍👍
@JumpermanTech
@JumpermanTech 4 жыл бұрын
Thank you for the constant support! Always appreicate you❤
@brahyanrengifo5232
@brahyanrengifo5232 Жыл бұрын
Thank you for the information! It helped a lot
@alexeytech1495
@alexeytech1495 4 жыл бұрын
Great understandable material. 👍
@JumpermanTech
@JumpermanTech 4 жыл бұрын
Thank you! Always appreicate your support. You're the best❤ New video every week!!
@eliaswakim2256
@eliaswakim2256 3 жыл бұрын
Thank you this was very easy to understand
@ZeEnderCat777
@ZeEnderCat777 Жыл бұрын
When measure Superheat and Subcooling, where would one put the thermometer? For Superheat, the pressure gauge would go where the suction line access port is (but if there isn't one, where would you put the access port?), but would the proper place to read temperature be at the END of the suction line right off of the compressor? Additionally, for measuring Subcooling, the pressure gauge would go where the liquid line access port is (but if there isn't one, where would you put the access port?), but would you put the thermometer right before the metering/expansion device? LASTLY, how would reading the discharge line work, as there usually isn't an access port? Would you simply read temperature with a thermometer on the discharge line as it ENTERS the condenser and as it EXITS the condenser?
@musixfor_u1232
@musixfor_u1232 2 жыл бұрын
bro your expalaination very helpful thank youuu 👍🏼👍🏼
@missrachel2
@missrachel2 2 жыл бұрын
doing homework thank u so much the book doesn't explain how to calculate I appreciate it
@brahim21261
@brahim21261 2 жыл бұрын
Very very helpfu en easy 2 understand
@jessegomez3409
@jessegomez3409 9 ай бұрын
Where do you measure your high side pressure? I’ve been told that you shouldn’t take this reading from the service port at the compressor(discharge line). Instead, you should try to get your high side pressure reading after your condenser(liquid line). I know some, maybe most rooftop package units do not have a port to hook up to after the condenser. Is this accurate at all? Good stuff, I enjoy your content.
@phantomf41
@phantomf41 2 ай бұрын
He is talking about attaching a pipe clamp thermometer to measure temperature. Not hooking up to port to measure pressure.
@baskar7791
@baskar7791 3 жыл бұрын
Thanks for sharing 👍👍👍 your knowledge, helpful video thank you.
@robbiebritt8997
@robbiebritt8997 3 жыл бұрын
In regards to mini split heat pump units, if you are meant to use the sub cooling method as a way to check refrigerant charge because of EEV in outdoor unit, how are you able to do it if there is only 1 service port on the Suction line and nothing on the liquid line? a lot of mini split systems seem to have this set up. thanks!
@gooddeedsleadto7499
@gooddeedsleadto7499 3 жыл бұрын
Awesome explanation. The required superheat ensures no liquid enters the compressor & The required supercool ensures no vapor enters the expansion orifice. Any of your KZbin explains what happens to super heat & sub cooling when it is humid?
@akbarshaikh4053
@akbarshaikh4053 4 жыл бұрын
How to measure temp of refrigerant leaving evap or condenser.? Which instrument to be use? Temp measured will be cu pipe surface temp ?
@nicolerennie
@nicolerennie 4 жыл бұрын
very well explained & easy to follow along w the visuals🌟👩🏼‍🏭
@JumpermanTech
@JumpermanTech 4 жыл бұрын
Thank you!! Always appreicate your constant support❤ New video every week!😎
@nickalesroman3108
@nickalesroman3108 4 жыл бұрын
amazing video thank you
@JumpermanTech
@JumpermanTech 4 жыл бұрын
Thank you so much! Glad you found the video amazing🙂 Your feedback is very much appreicated. Stay safe and stay tuned for new videos every week!
@uppulurisri8072
@uppulurisri8072 4 жыл бұрын
Can you please explain in praticle Show to calculate live
@NiceRepairGuys
@NiceRepairGuys Жыл бұрын
Thank you 👍
@Patso39
@Patso39 3 жыл бұрын
Thank You!
@kingredfox9389
@kingredfox9389 3 жыл бұрын
Awesome video and very easy to follow. Just a question though, at the end the range of sub cooling is 12-15 F, that’s the difference between the pipe temperature and SCT right?
@melekotmelekot5047
@melekotmelekot5047 2 жыл бұрын
clear explanation
@mustafaafify505
@mustafaafify505 2 жыл бұрын
Very good
@raguragu6958
@raguragu6958 4 жыл бұрын
vary well explained
@romeogad6680
@romeogad6680 Жыл бұрын
please do this video again with a real equipment, so we i can see how this done practical, it easy to understand then on paper
@Azm42255
@Azm42255 4 жыл бұрын
Good work
@Omrankasiga
@Omrankasiga 4 жыл бұрын
Hi. Please show one air condition for 2 room
@frankies1717
@frankies1717 4 жыл бұрын
Grate understanding! Thanks for the videos !
@JumpermanTech
@JumpermanTech 4 жыл бұрын
Thank you! Your feedback is greatly appreciated🙏 New video every week😎
@1971omi
@1971omi 4 жыл бұрын
As far as I know. Superheat = suction line - saturation. Because suction line has higher temperature than saturation. You mentioned opposite.
@JumpermanTech
@JumpermanTech 4 жыл бұрын
6:25
@JumpermanTech
@JumpermanTech 4 жыл бұрын
Thanks for watching tho :)
@familyplumbingheating2105
@familyplumbingheating2105 3 жыл бұрын
Your measurement for superheat @6:25 is backwards. Based off your own example you would have had a -10 degree superheat
@canman1088
@canman1088 3 жыл бұрын
And discharge superheat(taking temp. on discharge line)will tell you if valves are going bad in a compressor.
@sharicarper645
@sharicarper645 Жыл бұрын
The 3nd of the video I think was backwards
@TechnicalSkillwithVK
@TechnicalSkillwithVK Жыл бұрын
Superheat= Suction line temp - suction Saturation temp
@slam223
@slam223 4 жыл бұрын
Thanks to you sir
@moretti8136
@moretti8136 3 жыл бұрын
Great I’m even more confused
Class - What Superheat Signifies
17:07
HVAC School
Рет қаралды 252 М.
How to Read SUPERHEAT and SUBCOOLING
11:36
Word of Advice TV
Рет қаралды 626 М.
Who is More Stupid? #tiktok #sigmagirl #funny
0:27
CRAZY GREAPA
Рет қаралды 10 МЛН
Sigma girl VS Sigma Error girl 2  #shorts #sigma
0:27
Jin and Hattie
Рет қаралды 124 МЛН
Homemade Autocascade Refrigeration System (plus Anhydrous Ammonia)
15:57
Hyperspace Pirate
Рет қаралды 119 М.
Saturation, Superheat,  Subcooling
30:58
Love2HVAC with Ty Branaman
Рет қаралды 205 М.
Troubleshooting With Sat Temps, Superheat, & Subcooling! 5 Possible Problems!!
18:48
I WANT IT COLD! Charging 410A by superheat and subcooling
8:55
Iron Shield Heating & Air
Рет қаралды 16 М.
How To Check Superheat & Subcooling On An HVAC System
16:03
The DIY HVAC Guy
Рет қаралды 120 М.
Finding Target Superheat
15:58
HVAC School
Рет қаралды 21 М.
Temperature Rise How to Measure it and Why it's Important
7:54
TAS Academy HVAC Training Videos
Рет қаралды 8 М.
AC Pressures, Subcooling and Superheat
29:52
HVAC School
Рет қаралды 269 М.
DIY Vapor Compression Refrigeration System
28:06
Hyperspace Pirate
Рет қаралды 1,2 МЛН