Kitchen Counter Electrical - Code Minimum

  Рет қаралды 41,213

Electric Pro Academy

Electric Pro Academy

Күн бұрын

Пікірлер: 51
@theangryrktkt8385
@theangryrktkt8385 Жыл бұрын
Fantastic video! No rambling on or 5 minute pre-amble. Precise and succinct. Good job!!
@YSCDIY
@YSCDIY 10 ай бұрын
Amazing!this is the most clear explanation of the receptacle code in KZbin! Thank you. Now I know what’s going on!!
@icevariable9600
@icevariable9600 2 жыл бұрын
Excellent. We're working in an apartment complex and are installing outlets and switches. As plans keep changing, it got a little confusing regarding which outlets were to be GFCI and which receptacles were 15A or 20A (back to the dedicated receptacle or multiple receptacles on a circuit issue). Then there was the laundry room, and distance of receptacle to the washer. Am really finding value in your videos. Thanks.
@keithharrington8715
@keithharrington8715 2 жыл бұрын
Around time 5:00 you talked about appliance garages. 210.8 says the gfci must be readily accessible. This indicates that the recepticles inside the garage must be gfci protected but cannot be a gfci. Readily accessible definition talks about not overcoming obstacles to operate. Keep up the great work bro.
@keithharrington8715
@keithharrington8715 2 жыл бұрын
Also, 210.52.(C).(3). Talks about appliance garage recepticles not counting as the required counter top recepticles for spacing, however, I expect 210.8.(6). Still requires them to be gfci protected.
@jessicat3951
@jessicat3951 Жыл бұрын
Very useful! I wish you covered voltage and GFCI, but I will look in your other videos to try to find it.
@meganw6007
@meganw6007 2 жыл бұрын
I've got a ~1962 build house, where all the 12-2 are white (I had to do a double and triple take on that to make sure I was reading the NM-B jacket right), and it bugs me so much that the peninsula doesn't have a receptacle on it. It sure would be way more convenient than having to resort to the receptacles on the other side of the (albeit small) kitchen. Seeing code like this, where it is now required to have receptacles there, makes me so glad for residents and owners going forward, that they're going to have so much more convenient access to power, and so much LESS risk to health/safety by extension cables and malarkey like that that have caused far too many fires over the decades.
@garbo8962
@garbo8962 Жыл бұрын
Type NM-B cable did not come out until the 1980's. Therefore original wire in all homes built in 1962 would be type NM cable. Somebody woke NEC up to report type NM cables in hot attic down South were detereating.so they rep laced what appeared to be a type TW insulation with far superior appearing type TWHN insulation. Best practice is to always install more receptacles closer together then the code requires. My house was built in 1964 and except ft or the kitchen glibly had #14 guage type NM cable with a flimsy #16 guage ground wire. House only had 19 receptacles when I moved in but added over 25 over the years. Some did not get used for over 20'years until I moved furniture around..I have central AC but installed a dedicated 20'amp receptacle under every bedroom window in case I had to th ft ow in a temporary window aur conditioner.. Also added six three way switches & two four way switches.
@meganw6007
@meganw6007 Жыл бұрын
@@garbo8962 THANK YOU for typing that all out!! I often wonder about naming, but hadn't yet looked up (or remembered?) what the "-B" was for nonmetallic (NM) cable, so thanks for explaining that bit of history! And good on you for adding in all those ~25+ receptacles!
@meganw6007
@meganw6007 2 жыл бұрын
As it pertains to "whenever electricity comes through a finished wall it is referred to as an outlet," (1:41 in video, 6:05 in review) does that even include things like junction boxes, where there's no light or switch or receptacle, but merely some junctions? Or what about just plain wall-plates where there's no receptacle or switch, but live wires BEHIND the plate? Are those included in "outlet"?
@pharpester
@pharpester 9 ай бұрын
Can you talk about the new 2023 NEC code for kitchens: Islands or Peninsula’s? Or do you already have a video addressing these changes.
@multifacetedmovement5418
@multifacetedmovement5418 11 ай бұрын
Question for ya and hoping I could get your input as soon as you are able! We are doing a very custom home for a client, they don't want to see receptacles on the wall or anything and make my life hard. They have an office, all countertops around north, east and west walls, however they also have cabinets. Would I need to follow 2/4' rule for these counter top spaces for an office? Completely detached in another section from the kitchen ? Or can I just use general 6/12 rule for wall space and make the cabinet guys cut them in to their cabinets around 18" from sub floor? I hope this makes sense and your answer would mean the world to me
@YSCDIY
@YSCDIY 10 ай бұрын
Hi , I still confused about the outlet meaning. So, about the code, the 4 feet rule is fitting for even lighting switch and any other “outlet” that is not only for “receptacle outlet”, is that right? Thanks.
@virtualyeux
@virtualyeux 2 жыл бұрын
Your video is really useful. I still have a question or maybe more kind of an issue. We do not want outlets on the backsplash, we were thinking about having an outlet strip under the wall cabinet, but it seems this option is not valid (up to code). Is there any option for not having the outlets on the wall of the backslapsh nor the counter???
@mannynemer5316
@mannynemer5316 2 жыл бұрын
Plugmold
@simonealexander7626
@simonealexander7626 2 жыл бұрын
Came across your profile when searching for someone who may have an answer to my question. I'm in the middle of a new build and opted not to pay for the kitchen island through the builder and I want to personalize and get my kitchen island to my liking. I've been reading that per 2020 NEC guidelines you have to have 1-2 electrical outlets on kitchen islands. So will I be able to put my own kitchen island in if I don't get an island through the builder? Because once they put flooring in I'm not sure how electrical would be achieved. Especially with it being a concrete slab.
@keithharrington8715
@keithharrington8715 2 жыл бұрын
If you have not done this yet, he is right. Have the builder run power to the island/,island location for your future use. This is a link toa KZbin video from THIS OLD HOUSES showing exactly what you asked about. kzbin.info/www/bejne/b2iYZ4yZn7d2qdU
@trevor5290
@trevor5290 2 жыл бұрын
A concrete slab won't slow anyone down from drilling threw it. But you have to be careful if you have under floor heating... one nick and the entire thing is useless.
@ecko2013
@ecko2013 4 ай бұрын
Could you use 15 amp outlets?
@oddopops1327
@oddopops1327 10 ай бұрын
👍👍😉😉 Thank you!
@blessnorthamerica7919
@blessnorthamerica7919 10 ай бұрын
What about the dishwasher receptacle ?
@EastCoastReefer
@EastCoastReefer Жыл бұрын
Do these rules apply to a basement wet bar?
@davidmatias6239
@davidmatias6239 4 ай бұрын
What’s the closest distance required for an outlet to be installed to a stovetop ?
@ElectricProAcademy
@ElectricProAcademy 4 ай бұрын
An outlet must be installed within 24" of wall space from a break in the countertop caused by an obstruction such as a sink, stove or similar other.
@admirableawesome2317
@admirableawesome2317 Жыл бұрын
PLEASE DO MORE OF THESE!!!@!@!@
@jamesrockford6700
@jamesrockford6700 Жыл бұрын
I found that mounting the outlets horizonal above counter tops makes it easier to plug two items in.
@ibrahimwehbe1153
@ibrahimwehbe1153 Жыл бұрын
Well explained
@meganw6007
@meganw6007 2 жыл бұрын
Aside from cost, would there really be any problems with putting a receptacle in every single stud's 16"?? Like, could one for new work put in receptacles every single possible place along counters or floor lines? Is cost of the receptacles and for doing the labor the only thing preventing this? Is the voltage drop along the line/circuit and the increased number of possible points of failure negligible or significant enough to render an upper limitation on how many receptacles is reasonable?
@CoolHandLouis
@CoolHandLouis 2 жыл бұрын
@@ElectricProAcademy Some places have a local code limit.
@Californians_go_home
@Californians_go_home Жыл бұрын
⭕️You’ll have to update the 2023 code change for requiring receptacles on islands and peninsulas. They are no longer required. You just need to provide future means to add them, like a conduit or junction box. Major code change.
@robertapreston4200
@robertapreston4200 Жыл бұрын
Awesome!😎💯😎
@z1522
@z1522 Жыл бұрын
If the circuits are 20A. and GFCI protected, why does no one ever seem to install actual 20A. receptacles at each outlet? This has bugged me forever.
@ElectricProAcademy
@ElectricProAcademy Жыл бұрын
It's very rare to have 20A appliances in a residential setting in our part of the country. The 15A outlet is capable of carrying the circuit load, but not supporting a 20A appliance plugged into one individual outlet.
@fevgg
@fevgg Жыл бұрын
You said that minimum 2 circuits required for the kitchen. You have 4 receptacles in the video. Does it mean you installed 4 circuits or just 2 receptacles on each circuit?
@vids595
@vids595 Жыл бұрын
Multiple outlets can be on 1 circuit.
@fevgg
@fevgg Жыл бұрын
@@vids595 got it thanks. Just called city, they confirmed 2 circuit 2 outlet each, 20A GFCI protected
@BigPictureYT
@BigPictureYT Жыл бұрын
Excellent.
@mauroaparicio1855
@mauroaparicio1855 2 жыл бұрын
good video but the aulet has to be 3 feet away from the sink consiter wet area
@keithharrington8715
@keithharrington8715 2 жыл бұрын
Sir, nec 210..(A,).(7). Uses a distance of 6 feet. If you have a better reference please let me know.
@TheLucasthatyouknow
@TheLucasthatyouknow Жыл бұрын
210.52 in 2020 Dwelling Unit Receptacle Outlets
@jerrypruden887
@jerrypruden887 2 жыл бұрын
We use 15 amp split receptacles
@orlandosparks831
@orlandosparks831 2 жыл бұрын
@jameskarrie298 this answer is VERY wrong. you can NOT use a 15 amp receptacle on a 20 amp breaker. it is the opposite. you CAN use a 20 amp receptacle on a 15 amp breaker. if you do it your way the receptacle will melt or catch fire before breaker pops.
@orlandosparks831
@orlandosparks831 Жыл бұрын
@James Karrie DUDE READ WHAT YOU OPRIGANELY WROTE, you stated using 15 AMP receptacle on 20 amp circuit. you said 15 amp receptacle not 20 amp... you said i was wrong because you stated the amount of receptacles on a 20 circuit not the amperage of the receptacle itself.. You CAN NOT HAVE ANY 15 AMP RECEPTICLE ON A 20 AMP BREAKER PERIOD..
@orlandosparks831
@orlandosparks831 Жыл бұрын
You are talking about amount of receptacle on one circuit compared to type of receptacle which will mess people up causing them to buy the cheaper one and fail inspection and cause a fire in there home...
@orlandosparks831
@orlandosparks831 Жыл бұрын
@James Karrie well you definitely got me on that one but i could never see any inspector letting that go as they have the last say in the end. i wish i could save some cash using all 15 amp receptacles in my new house.
@neverknow69
@neverknow69 Жыл бұрын
@@orlandosparks831 The reason for this is no appliances are made that plug into a standard outlet that draw more than 15apms. Suppose one could plug many into a 3way adapter. But that would go against the labeled purpose of the adapter.
@AndresPerez-tc5pr
@AndresPerez-tc5pr 2 жыл бұрын
👌👍
@talbertadams6586
@talbertadams6586 5 ай бұрын
This video should be removed from KZbin. It outdated and does not comply with the current 2023 code.
@Nonedw
@Nonedw 4 ай бұрын
How so exactly?
@adityachoubey1845
@adityachoubey1845 8 күн бұрын
Only needs to be updated, not removed. Like others have pointed out, the 2023 NEC has changed for peninsula/island countertop. More specifically NEC 210.52(C)(3) needs to be highlighted. Ryan Jackson's video on this explains this well for the optional aspect of this implementation.
Water Heater and Sump Pump Outlets - Code Minimum
2:37
Electric Pro Academy
Рет қаралды 5 М.
Kitchen islands and peninsulas in the 2023 National Electrical Code
17:14
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
IL'HAN - Qalqam | Official Music Video
03:17
Ilhan Ihsanov
Рет қаралды 700 М.
Support each other🤝
00:31
ISSEI / いっせい
Рет қаралды 81 МЛН
How To Wire A Kitchen Island For Receptacles - Metal Clad (MC) Cable Installation
16:26
Electrical Home Runs
7:37
Electric Pro Academy
Рет қаралды 106 М.
Where and Why Do We Need AFCI Protection?
12:45
Electrician U
Рет қаралды 177 М.
6 Electrical Code Myths people Should Stop Believing
10:14
Backyard Maine
Рет қаралды 105 М.
Dwelling unit kitchen receptacle requirements (2020 edition).
15:20
Garage Wiring - Code Minimum
7:02
Electric Pro Academy
Рет қаралды 23 М.
Outlet Receptacle Spacing - Code Minimum
5:04
Electric Pro Academy
Рет қаралды 56 М.
Won't These Melt?!? 15amp Receptacles on 20 amp Circuits!!!
11:47
Electrician U
Рет қаралды 1,3 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН