Learn How to do a Residential Plumbing Final Inspection

  Рет қаралды 10,067

PPG

PPG

Күн бұрын

Пікірлер: 69
@sa-nn1ny
@sa-nn1ny 2 жыл бұрын
This is the most informative construction channel on youtube (it is REAL WORLD BASED). How does it not have 500,000 -plus subscriptions?
@PPG1967
@PPG1967 2 жыл бұрын
Wow!!...I appreciate you saying that. I'm trying to get it there, it's taking a lot longer than I thought.
@PPG1967
@PPG1967 2 жыл бұрын
I appreciate your feedback, and thanks for watching!!
@victorlopez9530
@victorlopez9530 Жыл бұрын
I have a 1940s house and it's apparent that the previous owners did a lot of DIYing. I was looking for info on the proper way to install a dishwasher drain, with a double sink and a garbage disposal. THANK YOU SO MUCH!!!!
@PPG1967
@PPG1967 Жыл бұрын
I appreciate you watching!!
@jimlopez8197
@jimlopez8197 2 жыл бұрын
I’d love to see what you look for in rough pluming as well as underground or in the slab plumbing.
@PPG1967
@PPG1967 2 жыл бұрын
Will do..
@PPG1967
@PPG1967 2 жыл бұрын
Thanks for watching!!
@larrycraft3901
@larrycraft3901 2 жыл бұрын
Didn't check temps, fixture clearances, didn't turn shower of the tub/shower on to make sure that's not leaking. Inline mixing valves not allowed on showers, verify handheld is a112.18.1 compliant, is tub caulked to floor.
@PPG1967
@PPG1967 2 жыл бұрын
So, what Plumbing Code Book are you referencing??...my videos are based on the 2018 IPC.
@larrycraft3901
@larrycraft3901 Жыл бұрын
@@PPG1967 ipc doesn't cover residential. You would need the irc
@capefearcapt4679
@capefearcapt4679 2 жыл бұрын
Good catch with the air gap.
@PPG1967
@PPG1967 2 жыл бұрын
I appreciate your comment.
@everythinghomerepair1747
@everythinghomerepair1747 2 жыл бұрын
Nice through video. The addition of the graphics really helped me to see what you were talking about.
@PPG1967
@PPG1967 2 жыл бұрын
I appreciate your feedback...thanks for watching!!
@Roy-ij1wq
@Roy-ij1wq Жыл бұрын
At 4:45 in the video did you say to "seal and caulk" at the base of the toilet? If so, where do you find this in the code? If the toilet is caulked, wouldn't this damage the floor and cause a leak below the toilet if the wax seal fails?
@PPG1967
@PPG1967 Жыл бұрын
If you're familiar with the 2018 IRC or IPC, it's under Plumbing Fixtures, Installation section.
@PPG1967
@PPG1967 Жыл бұрын
It states, when fixtures come in contact with walls and floors, the contact area shall be watertight.
@Roy-ij1wq
@Roy-ij1wq Жыл бұрын
@@PPG1967 Doesn't the wax seal make it water tight? If the wax seal fails, water will be trapped between the flange and perimeter of the fixture if it is caulked and sitting on top of a floor that may or may not be waterproof. My bathroom floor is 3/4" tongue and groove oak flooring and it is not waterproof. If the wax seal fails, I want to know about it before the floor is destroyed.
@PPG1967
@PPG1967 Жыл бұрын
Code states, " when fixtures come in contact with walls and floors, the contact area shall be watertight."
@patrickreaves8053
@patrickreaves8053 14 күн бұрын
2 straps at the top and bottom 1/3 of the water heaters at each w/h are missing! How was this missed?
@PPG1967
@PPG1967 Күн бұрын
What code book are you referencing???....UPC?
@rogerstoneburner
@rogerstoneburner 2 жыл бұрын
Do those runs off the TPR valves have too many 90-degree turns? at 14:25. Also, no copper on those?
@PPG1967
@PPG1967 2 жыл бұрын
So, that CPVC has a higher temperature value. That is a lot of elbows, however it's allowed.
@PPG1967
@PPG1967 2 жыл бұрын
I appreciate your feedback.
@rogerstoneburner
@rogerstoneburner 2 жыл бұрын
@@PPG1967 great to know, thanks!
@wsfwsf1497
@wsfwsf1497 Жыл бұрын
No air gap or high loop for the DW?
@PPG1967
@PPG1967 Жыл бұрын
The drainage hose is attached up high under the counter.
@dustinphillips8462
@dustinphillips8462 Жыл бұрын
Why didn't you fill the sinks for part of inspection?
@PPG1967
@PPG1967 Жыл бұрын
So, why would I do that??
@CharlesBuell
@CharlesBuell Жыл бұрын
So a ventless dryer?
@PPG1967
@PPG1967 Жыл бұрын
This is a Plumbing Final Inspection video. Dryer exhaust duct is on the Mechanical Inspection.
@PPG1967
@PPG1967 Жыл бұрын
I appreciate you watching.
@wsfwsf1497
@wsfwsf1497 Жыл бұрын
In your area, PVC is allowed for the TPR valve?
@PPG1967
@PPG1967 Жыл бұрын
Yes sir.
@Eldon0001
@Eldon0001 Жыл бұрын
Where could I find diagrams like this? Is their a special book? Besides it being in the national code books It would really help. Thank you! 3:28
@PPG1967
@PPG1967 Жыл бұрын
Google
@PPG1967
@PPG1967 Жыл бұрын
I appreciate you watching!!
@mpsd208
@mpsd208 2 жыл бұрын
Question about the T&P relief tubes: The code states that the piping shall discharge in the same room as the water heater. Those two in the video go through the wall. Can you explain the situation here if this was approved and how it differs from the code?
@PPG1967
@PPG1967 2 жыл бұрын
So, what code book are you referencing??
@mpsd208
@mpsd208 2 жыл бұрын
2018 IPC, same as you. 504.6 #2 is what I was referring to. I wasn’t trying to challenge you, I was just asking. I’m fairly new to the inspection game, so I welcome any help and explanation I can get. I looked at the T&P section just before watching this video and I wondered about what I saw vs. what I read. Any clarification you can provide is appreciated. Thank you.
@jimzimmerman5288
@jimzimmerman5288 Жыл бұрын
Terminate at an approved location. That is what is required.
@vafrog02
@vafrog02 2 жыл бұрын
what book you use for electrical and plumbing for diagrams? thanks
@PPG1967
@PPG1967 2 жыл бұрын
The 2018 IPC & 2020 NEC.
@PPG1967
@PPG1967 2 жыл бұрын
I appreciate you watching!!
@wsfwsf1497
@wsfwsf1497 Жыл бұрын
Get an escutcheon flange on that toilet supply. Bug city.
@PPG1967
@PPG1967 Жыл бұрын
Ok, I appreciate your feedback.
@jamiefigley
@jamiefigley 2 күн бұрын
No bowl test?
@PPG1967
@PPG1967 Күн бұрын
What's a bowl test?
@jamiefigley
@jamiefigley Күн бұрын
@@PPG1967 a final test that has to be done to satisfy city plumbing inspector. Balloon off stack at the base and at the roof, make sure traps have water and fill the toilet bowl with water to make sure it holds. It’s how you make sure you have a good seal on all fixtures and haven’t driven any drywall screws through your drains. I’ve never gotten away without doing a bowl test, it’s code
@PPG1967
@PPG1967 Күн бұрын
Interesting...what code book are you using, and where are you located ??
@jamiefigley
@jamiefigley 23 сағат бұрын
Ohio…IPC. It’s just something they always ask for at my final…maybe not described in IPC but I’m not sure of another way to make sure fixtures are air tight. Toilet seal is often an issue. Won’t leak water but sucks air
@PPG1967
@PPG1967 30 минут бұрын
Interesting, I never stop learning.
@fnbgo22
@fnbgo22 2 жыл бұрын
How about clean outs at final ?
@PPG1967
@PPG1967 2 жыл бұрын
Down here in Atlanta we have a sewer lateral (cleanout) inspection. Prior to the Plumbing Final Inspection.
@PPG1967
@PPG1967 2 жыл бұрын
Thanks for commenting.
@TheFlippinRedhead
@TheFlippinRedhead 2 жыл бұрын
Is a gas test not required a final plumbing inspection in GA?
@PPG1967
@PPG1967 2 жыл бұрын
That's usually conducted on the mechanical rough inspection.
@jimzimmerman5288
@jimzimmerman5288 Жыл бұрын
The shower that you did not turn on is wrong. Supposed to be able to turn the shower on with our the water shooting at you. Check your codes. The door should have been at the left.
@PPG1967
@PPG1967 Жыл бұрын
So, where is that in the 2018 IRC or 2018 IPC????... I'll wait.
@PPG1967
@PPG1967 Жыл бұрын
Are you a plumbing contractor?
@jesuszuniga1501
@jesuszuniga1501 Жыл бұрын
I really don’t think that would make sense, code wise. If you turn on the water and it’s hot, you’d have to reach over in the hot water to be able to lower the temperature
@bigcountry3229
@bigcountry3229 2 жыл бұрын
Hey Bro really love what you're doing, helps people whey more then you know. Would like to talk to you if you can find some time.
@PPG1967
@PPG1967 2 жыл бұрын
Email me precisepropertygroup@gmail.com. I'll provide you with my contact number.
@capefearcapt4679
@capefearcapt4679 2 жыл бұрын
Reveal around the rodent proofing.
@PPG1967
@PPG1967 2 жыл бұрын
Ok, I don't understand what you're referring too.
@capefearcapt4679
@capefearcapt4679 2 жыл бұрын
@@PPG1967 I spotted a gap or "reveal" around the rodent proofing exclusion devices on the pipes under the sinks.
@jimzimmerman5288
@jimzimmerman5288 Жыл бұрын
PPG, retired building inspector.
@PPG1967
@PPG1967 Жыл бұрын
Oh ok.
10 Reasons Why You'd FAIL a Plumbing Inspection! | GOT2LEARN
7:36
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
Residential Building Code Violations (Part 1)
18:01
PPG
Рет қаралды 93 М.
Plumbing Code Violations (Part 1)
8:57
PPG
Рет қаралды 214 М.
The #1 DWV Plumbing Mistake (and how to prevent it).
3:07
Hammerpedia
Рет қаралды 4,9 МЛН
Part 1: Plumbing code - waste and venting pipe size
13:15
The Plumbing Academy, Inc.
Рет қаралды 487 М.
Top 5 Residential Electrical Code Violations
5:06
PPG
Рет қаралды 105 М.
Drain, Waste & Vent System | Off Grid Homestead Build Ep19Pt2 | The ShabinLife
31:52
ShabinLife - Living Simple. Loving Nature.
Рет қаралды 638 М.
Electrical Rough-In Inspection (New Construction)
10:34
Underground to Final Inspections  [IRC/CRC] - The Sequence of Building Inspections
10:16