SGP407 Biased Differential Protection of Transformers

  Рет қаралды 22,712

Lectures in Electrical Engineering

Lectures in Electrical Engineering

Күн бұрын

Пікірлер: 21
@TheAfricanEngineer
@TheAfricanEngineer 3 жыл бұрын
I cant thank you enough for making this playlist. Carries me through my protection and switchgear course
@ibrahimkuttymk2387
@ibrahimkuttymk2387 4 жыл бұрын
sir your teaching method is good and super .wishing very long life.
@RajeshPatel-vf7ee
@RajeshPatel-vf7ee 2 жыл бұрын
Sir your lectures are very useful to me.
@himanshu2232
@himanshu2232 4 жыл бұрын
Thanks sir ji for again Nice vedio.
@Dhinakar_21
@Dhinakar_21 2 жыл бұрын
Sir, due to circulating current produced bcoz of phase to phase fault in secondary, secondary current increases. But how correspondingly in primary the current has been increased?
@PramodKumar-zl4gq
@PramodKumar-zl4gq 2 жыл бұрын
Excellent lecture sir
@mohanjiju9622
@mohanjiju9622 4 жыл бұрын
Sir super teaching sir.❤️
@kudzaibmataya9803
@kudzaibmataya9803 3 жыл бұрын
i would want to know more about high and low impedance differential protection
@surendrakverma555
@surendrakverma555 2 жыл бұрын
Very good 🙏🙏🙏🙏🙏🙏
@himanshusati3066
@himanshusati3066 4 жыл бұрын
Dear sir, kindly suggest the list of high impedance relay and low impedance relay. And where we used high impedance relay and where low impedance relay.
@moumitamondal5188
@moumitamondal5188 4 жыл бұрын
Sir, the connection of CT should be opposite to transformer connection but within CT which side is to be taken for neutral and which side for connecting the pilot wires? How to know
@AbdulAzeez-vp2zf
@AbdulAzeez-vp2zf 3 жыл бұрын
Really super
@nagbarc
@nagbarc 2 жыл бұрын
If earth fault occurred at primary side how the differencial CTs are sense the fault current, because earth fault current go's to source neutral. Please explain
@seshaiahkota2284
@seshaiahkota2284 4 жыл бұрын
In internal faults, in phase fault in secondary side why the current is not passed through CT?
@yogeshnanda5181
@yogeshnanda5181 4 жыл бұрын
Please sir upload all the videos of switch gear and protection asap
@tnsworld7005
@tnsworld7005 3 жыл бұрын
Thanks sir
@niharranjansen5218
@niharranjansen5218 4 жыл бұрын
Sir, As you said the Differential protection can not protect the transformer from external fault but there is a chance that the fault can damage the transformer . So what kind of protection should we use to protect the transformer from external fault. Should you use earth fault protection scheme ?
@ranjith.s
@ranjith.s Жыл бұрын
Yes Earth fault and O/C relay
@Learnsolar
@Learnsolar 4 жыл бұрын
Dear sir, Why differntial relay Pickup set value and Bias set value is different.
@Learnsolar
@Learnsolar 4 жыл бұрын
Tq so much sir,but how much different between pick up value and bias value is correct. Like my pick up set in = R=1.04,Y=1.5,B=1.6 So what is the correct bias set value and how to calculate. Please sir 🙏
@sudampatra5608
@sudampatra5608 Жыл бұрын
Sir can you please explain differential relay calculations
SGP408 Harmonic Restraint Differential Relay
9:31
Lectures in Electrical Engineering
Рет қаралды 13 М.
SGP405 Problems and Solution for differential Protection of Transformers
20:14
Lectures in Electrical Engineering
Рет қаралды 15 М.
Do you love Blackpink?🖤🩷
00:23
Karina
Рет қаралды 25 МЛН
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 102 МЛН
SGP418 Rotor Fault Protection of Alternator
15:24
Lectures in Electrical Engineering
Рет қаралды 23 М.
SGP323 Biased or Percentage Differential Relay
19:51
Lectures in Electrical Engineering
Рет қаралды 25 М.
SGP414 Merz Price or Biased Differential Protection of Alternators
15:33
Lectures in Electrical Engineering
Рет қаралды 17 М.
High Voltage Switchgear | An Introductory Guide | TheElectricalGuy
16:08
Gaurav J - TheElectricalGuy
Рет қаралды 22 М.
SGP401 Types of Faults in Transformers
18:32
Lectures in Electrical Engineering
Рет қаралды 36 М.
SGP411 Types of  Faults in  Alternators
22:41
Lectures in Electrical Engineering
Рет қаралды 32 М.