Je pipe or la bech ma isolatar lagana chahea necha danasa kya fada
@ramelectricals90803 жыл бұрын
Good explanation keep it up and going like this. I wish you all the best
@entireelectricals3 жыл бұрын
Thank You
@asaskui4 жыл бұрын
Do the "red colour" support must be insulation material?
@entireelectricals4 жыл бұрын
Yes. Sir,
@nelsonmaranonjr.5373 жыл бұрын
Nice.. 👍😁
@chrispusmalombe71902 жыл бұрын
Sir, how did the copper tape and the round tube adapt? Did you make the tube a little flat?
@entireelectricals2 жыл бұрын
Dear sir, As per IS rules 3404 Required Lightning Strock chapter to lighting Arrester and grounding To earth to earthing Strip... Mostly used copper Strip Size --- 25 mm x 3 mm Or GI Hot Dip Strip ---- 25 mm x 6 mm This Strip is Isolated to Building Structure. Not Used any. alluminium Part this System because Alluminium matal Melting point is low.... Thank you. Watching Video Thanks
@supernova-bekha94102 жыл бұрын
Dear Sir, Please let me know. Does human body affect if we touch copper strip at the time of lightening on our house lightening arrestor?
@entireelectricals2 жыл бұрын
Ok This time till working Second vidio is improved as bellow second vidio kzbin.info/www/bejne/i3bWfH9tj7GAmKM Thank you
@entireelectricals2 жыл бұрын
kzbin.info/www/bejne/i3bWfH9tj7GAmKM
@MannuHR104 жыл бұрын
sir ye btao inverter or ACDB ki earthing meom insulator lagana jaruri h kya
@entireelectricals4 жыл бұрын
Inverter is electronic based divice so required separatly isolated earthing with separate with Insulater support. Because short circuit current is damage control circuit for inverter e.g thistest, diodes, transistors, capacitors, and other micro controllers. So required isolated saprate earthing. But AC ---- DB is Power Electricals control box is required earthing satpratly. This is call sefty earthing ( body earthing ) this not required Insulater. Bus other equipment inverter, sefty required insulated wire or strip. To earth pit. Thanks you watching to our vidio.
@MannuHR104 жыл бұрын
i m agree with you sir i have done seperate earhing for inverter and ACDB but my main question is why we use insulator in inv an acdb earthing? LA earthing mein to reason h insulator use lrne ka but what about inv and ACDB
@entireelectricals4 жыл бұрын
Inverter is electronic DC unit AC DB is Power AC Unit. Insulater is used for following purpose 1) required separation. 2)Rani segasion protection to short Circuit. 3) Insulater is decrease short Circuit foult Damage to equipments. 4) physical good view. 5) Not mixing to leakage or shor current to use Insulater. 6) protection of over lapping Earthing Strip. Thank you.
@destiny41053 жыл бұрын
kitna dur tak fek deta hai tower se
@entireelectricals3 жыл бұрын
This Lightning Arrester is covered by approximately 10 mtr ( 30 feet )
@shwetaankale4 жыл бұрын
V informative video
@imviveksangwan3 жыл бұрын
What is the cost for two storey building?
@entireelectricals3 жыл бұрын
Approximately 30,000.00 25 mtr leagth Hight assumed.... all material and Labour ....on depending building Hight
@shakurshaiks29463 жыл бұрын
Rong fitting tower rod home ki tuch kakudadu
@entireelectricals2 жыл бұрын
I know sir...
@chinmoykoch95123 жыл бұрын
Insulator...
@ball_control3 жыл бұрын
nice video sir, I have one question, please answer can we connect the lightning arrester in home line earthing pit ? if we do so, can it harm home appliances ? Thanks in advance.
@entireelectricals3 жыл бұрын
Not connected to home earthing In case lightning Arrester is lighter Arrester . All Home equipments is Dameged. So not connected to lighting Arrester earthing to home earthing .. All earthing is isolated to use insulator for earthing strip .... Etc.. Thank for watching video....
@ball_control3 жыл бұрын
@@entireelectricals cleared, thanks sir
@sampsontendaimutsago19352 жыл бұрын
@@entireelectricals are you saying that we should not bond our regular earthing from supply to the lightning system?
@ashwinikumbhar68564 жыл бұрын
💐🌹😀😱
@prakashkumbhar96394 жыл бұрын
Chupach mast
@pinedastaglio65003 жыл бұрын
The fucking background music destroyed the vid!!!!
@entireelectricals3 жыл бұрын
Sir, I am Tray to my end to posible work better than this vidio...
@olavioluis55892 жыл бұрын
Your installation is good but not professional don't hammer ⚒️ screws use proper tools you are sharing your knowledge so don't feel offended