Linking PIDE Faceplates to a PIDE Instruction -- FactoryTalk View Studio

  Рет қаралды 12,689

Clifford Long

Clifford Long

Күн бұрын

Пікірлер: 12
@AbdullahAhmed-vj2vi
@AbdullahAhmed-vj2vi 2 жыл бұрын
Thanks a lot. We need a video like that about cascade. Thanks in advance
@4you327
@4you327 Жыл бұрын
I have a question why you use in rslogix 2 PIDE AND PIDE AUTOTUNE THEN WE JUST CALL PIDE.
@jbkuhlmann
@jbkuhlmann 4 жыл бұрын
Hi Clifford. Do you by any chance know if anything has changed during the last few years, regarding these parameters? I am working in FTW 11.00 and Logix 32.00. But many of my parameters seem to be missing, once I try to link my faceplate to my program? Jonas
@RDCINST
@RDCINST 4 жыл бұрын
jbkuhlmann sorry, I’m not sure. You would have to contact Rockwell. If you find out, please let me know. I will be upgrading to version 32 this fall.
@Fntaztc
@Fntaztc 4 жыл бұрын
I got this to work with FT 11 and Logix 32.02, see my post above about the Autotune button fix. Another option was to have a separate button for Autotune that called the parameter file directly.
@RDCINST
@RDCINST 4 жыл бұрын
Fntaztc thank-you very much for confirming this!
@jbkuhlmann
@jbkuhlmann 4 жыл бұрын
@@Fntaztc It turned out that the parameters from my program would not link with the faceplate as the software issued from my school was in Danish language (Denmark). Switching to English solved the problem. However, I recommend one should adjust these settings prior to designing anything, since every label and button was changed to '?' when switching language midways 😏
@brstilson
@brstilson 8 жыл бұрын
Your Autotune portion wasn't working, though. I'm having the same issue.
@RDCINST
@RDCINST 8 жыл бұрын
Your right Brian! Thanks for pointing that out. I will look into this and reply. It might not be until the fall though. I have a long list of things to do.
@strapt313
@strapt313 7 жыл бұрын
I think it's because you have to enable it in the PIDE parameter (AutotuneEN) setup or write a 1 and wire it to the FB. He only had input and output wired to the PIDE. I may be wrong.
@Fntaztc
@Fntaztc 4 жыл бұрын
This was driving me crazy too. There were two issues with this I believe. First, on the "Logix_PIDE_Trend" screen, the goto button parameter list for "Logix_PIDE_Autotune" should be {#1},{#2}. Next, the goto button parameter list for the Trend button on the "Logix_PIDE" screen needs to be {#1},{#2} also. Without the {#2} on this screen, the Autotune screen doesn't know where to get its data from. Hope this helps. Thanks for the video.
@RDCINST
@RDCINST 4 жыл бұрын
Fntaztc thanks for figuring this out and responding! Much appreciated!
Setting up and verifying a PID block -- DeltaV 12.3.1
12:56
Clifford Long
Рет қаралды 28 М.
Oh No! My Doll Fell In The Dirt🤧💩
00:17
ToolTastic
Рет қаралды 13 МЛН
Dad gives best memory keeper
01:00
Justin Flom
Рет қаралды 20 МЛН
Building Faceplates in FactoryTalk® View ME/SE
39:14
The Reynolds Company
Рет қаралды 9 М.
Set Up PIDE Auto Tuning in Studio 5000
13:41
Tim Wilborne
Рет қаралды 20 М.
Real-time Data Logging Using RSLinx OPC and Excel
13:56
PLCGurus.NET
Рет қаралды 50 М.
Studio 5000 PIDE Simulation Programming In Function Block
42:08
Shane Welcher
Рет қаралды 13 М.
Oh No! My Doll Fell In The Dirt🤧💩
00:17
ToolTastic
Рет қаралды 13 МЛН