Your a well of knowledge. And you know how t communicate effectively. Thank you very much
@811chicago55 ай бұрын
Thank you and you are very welcome!
@BoxofRain-ff4td5 ай бұрын
Love these how to videos, thanks!
@811chicago55 ай бұрын
Thank you very much! I'll have a few more short videos like this coming soon.
@yiazmat71045 ай бұрын
I love steel services to Steel Main so much actually. though tracers on plastic are braindead easy to locate but it's such a chore when it is no longer accessible. have to backfed on 200k from nearby service assuming every service and the main they are connected to are plastic on that street
@811chicago55 ай бұрын
Plastic gas services with trace wires are easy to locate when the trace wire is properly connected to the main line. However, in your case, the trace wire might be buried beneath concrete or cut too short to the surface. Never assume anything, especially when dealing with natural gas. Ensure these services are correctly located by using a low frequency. Using 200 kHz carries a high risk of signal bleeding onto the water service, leading to its missmarking as a gas line. When encountering such issues, always push it back to the gas company for resolution.
@ohgeshy17605 ай бұрын
Would you be able to make a video on locating nodes for phone lines?